{"id":"https://openalex.org/W2000065976","doi":"https://doi.org/10.1109/iembs.2011.6090690","title":"Designing for reliable textile neonatal ECG monitoring using multi-sensor recordings","display_name":"Designing for reliable textile neonatal ECG monitoring using multi-sensor recordings","publication_year":2011,"publication_date":"2011-08-01","ids":{"openalex":"https://openalex.org/W2000065976","doi":"https://doi.org/10.1109/iembs.2011.6090690","mag":"2000065976","pmid":"https://pubmed.ncbi.nlm.nih.gov/22254846"},"language":"en","primary_location":{"id":"doi:10.1109/iembs.2011.6090690","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iembs.2011.6090690","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5084402279","display_name":"Sibrecht Bouwstra","orcid":null},"institutions":[{"id":"https://openalex.org/I83019370","display_name":"Eindhoven University of Technology","ror":"https://ror.org/02c2kyt77","country_code":"NL","type":"education","lineage":["https://openalex.org/I83019370"]}],"countries":["NL"],"is_corresponding":true,"raw_author_name":"S. Bouwstra","raw_affiliation_strings":["Department of Industrial Design, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven, the Netherlands. s.bouwstra@tue.nl","Department of Industrial Design, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven, The Netherlands"],"affiliations":[{"raw_affiliation_string":"Department of Industrial Design, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven, the Netherlands. s.bouwstra@tue.nl","institution_ids":["https://openalex.org/I83019370"]},{"raw_affiliation_string":"Department of Industrial Design, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven, The Netherlands","institution_ids":["https://openalex.org/I83019370"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5067951920","display_name":"W. Chen","orcid":null},"institutions":[{"id":"https://openalex.org/I83019370","display_name":"Eindhoven University of Technology","ror":"https://ror.org/02c2kyt77","country_code":"NL","type":"education","lineage":["https://openalex.org/I83019370"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"W. Chen","raw_affiliation_strings":["Department of Industrial Design, Eindhoven University of Technology, Eindhoven, MB, the Netherlands","Department of Industrial Design, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven, The Netherlands"],"affiliations":[{"raw_affiliation_string":"Department of Industrial Design, Eindhoven University of Technology, Eindhoven, MB, the Netherlands","institution_ids":["https://openalex.org/I83019370"]},{"raw_affiliation_string":"Department of Industrial Design, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven, The Netherlands","institution_ids":["https://openalex.org/I83019370"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5048253815","display_name":"Sidarto Bambang Oetomo","orcid":"https://orcid.org/0000-0002-1199-7390"},"institutions":[{"id":"https://openalex.org/I145872427","display_name":"Radboud University Nijmegen","ror":"https://ror.org/016xsfp80","country_code":"NL","type":"education","lineage":["https://openalex.org/I145872427"]},{"id":"https://openalex.org/I4210126394","display_name":"M\u00e1xima Medisch Centrum","ror":"https://ror.org/02x6rcb77","country_code":"NL","type":"healthcare","lineage":["https://openalex.org/I4210126394"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"S. B. Oetomo","raw_affiliation_strings":["Neonatal Intensive Care Unit, M\u00e1xima Medical Center, Veldhoven, MB, the Netherlands","Neonatal Intensive Care Unit, M\u00e1xima Medical Center, P.O. Box 7777, 5500 MB Veldhoven, the Netherlands"],"affiliations":[{"raw_affiliation_string":"Neonatal Intensive Care Unit, M\u00e1xima Medical Center, Veldhoven, MB, the Netherlands","institution_ids":["https://openalex.org/I4210126394","https://openalex.org/I145872427"]},{"raw_affiliation_string":"Neonatal Intensive Care Unit, M\u00e1xima Medical Center, P.O. Box 7777, 5500 MB Veldhoven, the Netherlands","institution_ids":["https://openalex.org/I4210126394","https://openalex.org/I145872427"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5001515134","display_name":"Loe Feijs","orcid":"https://orcid.org/0000-0002-3865-0215"},"institutions":[{"id":"https://openalex.org/I83019370","display_name":"Eindhoven University of Technology","ror":"https://ror.org/02c2kyt77","country_code":"NL","type":"education","lineage":["https://openalex.org/I83019370"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"L. M. G. Feijs","raw_affiliation_strings":["Department of Industrial Design, Eindhoven University of Technology, Eindhoven, MB, the Netherlands","Department of Industrial Design, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven, The Netherlands"],"affiliations":[{"raw_affiliation_string":"Department of Industrial Design, Eindhoven University of Technology, Eindhoven, MB, the Netherlands","institution_ids":["https://openalex.org/I83019370"]},{"raw_affiliation_string":"Department of Industrial Design, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven, The Netherlands","institution_ids":["https://openalex.org/I83019370"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5112394426","display_name":"P.J.M. Cluitmans","orcid":null},"institutions":[{"id":"https://openalex.org/I83019370","display_name":"Eindhoven University of Technology","ror":"https://ror.org/02c2kyt77","country_code":"NL","type":"education","lineage":["https://openalex.org/I83019370"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"P. J. M. Cluitmans","raw_affiliation_strings":["Department of Industrial Design, Eindhoven University of Technology, Eindhoven, MB, the Netherlands","Department of Electrical Engineering, Eindhoven University of Technology, P.O. Box 513, 5600 MB, Eindhoven, the Netherlands"],"affiliations":[{"raw_affiliation_string":"Department of Industrial Design, Eindhoven University of Technology, Eindhoven, MB, the Netherlands","institution_ids":["https://openalex.org/I83019370"]},{"raw_affiliation_string":"Department of Electrical Engineering, Eindhoven University of Technology, P.O. Box 513, 5600 MB, Eindhoven, the Netherlands","institution_ids":["https://openalex.org/I83019370"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5084402279"],"corresponding_institution_ids":["https://openalex.org/I83019370"],"apc_list":null,"apc_paid":null,"fwci":0.1954,"has_fulltext":false,"cited_by_count":13,"citation_normalized_percentile":{"value":0.6052534,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":"21","issue":null,"first_page":"2488","last_page":"2491"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13248","display_name":"Healthcare Technology and Patient Monitoring","score":0.9976000189781189,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/context","display_name":"Context (archaeology)","score":0.7060447335243225},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.647495687007904},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.609953761100769},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.4696466326713562},{"id":"https://openalex.org/keywords/neonatal-intensive-care-unit","display_name":"Neonatal intensive care unit","score":0.4502633213996887},{"id":"https://openalex.org/keywords/remote-patient-monitoring","display_name":"Remote patient monitoring","score":0.4294317066669464},{"id":"https://openalex.org/keywords/process","display_name":"Process (computing)","score":0.41170090436935425},{"id":"https://openalex.org/keywords/signal","display_name":"SIGNAL (programming language)","score":0.41068726778030396},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.09749680757522583}],"concepts":[{"id":"https://openalex.org/C2779343474","wikidata":"https://www.wikidata.org/wiki/Q3109175","display_name":"Context (archaeology)","level":2,"score":0.7060447335243225},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.647495687007904},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.609953761100769},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.4696466326713562},{"id":"https://openalex.org/C2777091541","wikidata":"https://www.wikidata.org/wiki/Q9008292","display_name":"Neonatal intensive care unit","level":2,"score":0.4502633213996887},{"id":"https://openalex.org/C175079658","wikidata":"https://www.wikidata.org/wiki/Q7312165","display_name":"Remote patient monitoring","level":2,"score":0.4294317066669464},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.41170090436935425},{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.41068726778030396},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.09749680757522583},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C118552586","wikidata":"https://www.wikidata.org/wiki/Q7867","display_name":"Psychiatry","level":1,"score":0.0},{"id":"https://openalex.org/C151730666","wikidata":"https://www.wikidata.org/wiki/Q7205","display_name":"Paleontology","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D004566","descriptor_name":"Electrodes","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004566","descriptor_name":"Electrodes","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004566","descriptor_name":"Electrodes","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D005240","descriptor_name":"Feasibility Studies","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D005240","descriptor_name":"Feasibility Studies","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D005240","descriptor_name":"Feasibility Studies","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007231","descriptor_name":"Infant, Newborn","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007231","descriptor_name":"Infant, Newborn","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007231","descriptor_name":"Infant, Newborn","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007234","descriptor_name":"Infant, Premature","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D007234","descriptor_name":"Infant, Premature","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D007234","descriptor_name":"Infant, Premature","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":6,"locations":[{"id":"doi:10.1109/iembs.2011.6090690","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iembs.2011.6090690","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","raw_type":"proceedings-article"},{"id":"pmid:22254846","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/22254846","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","raw_type":null},{"id":"pmh:oai:pure.tue.nl:openaire_cris_publications/da4e7b9f-93b8-4b74-9ad4-9dd74336f8ac","is_oa":false,"landing_page_url":"https://research.tue.nl/en/publications/da4e7b9f-93b8-4b74-9ad4-9dd74336f8ac","pdf_url":null,"source":{"id":"https://openalex.org/S4406922641","display_name":"TU/e Research Portal","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Bouwstra, S, Chen, W, Feijs, L M G, Bambang Oetomo, S & Cluitmans, P J M 2011, Designing for reliable textile neonatal ECG monitoring using multi-sensor recordings. in Proceedings of the 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC, 30 August - 3 September 2011, Boston, Massachussetts., 6090690, Institute of Electrical and Electronics Engineers, Piscataway, pp. 2488-2491, 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2011, Boston, MA, United States, 30/08/11. https://doi.org/10.1109/IEMBS.2011.6090690","raw_type":"info:eu-repo/semantics/publishedVersion"},{"id":"pmh:731972","is_oa":false,"landing_page_url":"http://library.tue.nl/csp/dare/LinkToRepository.csp?recordnumber=731972","pdf_url":null,"source":{"id":"https://openalex.org/S4406923046","display_name":"TU/e Research Portal (Eindhoven University of Technology)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":""},{"id":"pmh:oai:library.tue.nl:731972","is_oa":false,"landing_page_url":"http://repository.tue.nl/731972","pdf_url":null,"source":{"id":"https://openalex.org/S4406923046","display_name":"TU/e Research Portal (Eindhoven University of Technology)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":""},{"id":"pmh:tue:oai:pure.tue.nl:publications/da4e7b9f-93b8-4b74-9ad4-9dd74336f8ac","is_oa":false,"landing_page_url":"https://research.tue.nl/nl/publications/da4e7b9f-93b8-4b74-9ad4-9dd74336f8ac","pdf_url":null,"source":{"id":"https://openalex.org/S4306401843","display_name":"Data Archiving and Networked Services (DANS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1322597698","host_organization_name":"Royal Netherlands Academy of Arts and Sciences","host_organization_lineage":["https://openalex.org/I1322597698"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Proceedings of the 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC, 30 August - 3 September 2011, Boston, Massachussetts, 2488 - 2491","raw_type":"info:eu-repo/semantics/conferencepaper"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W373531798","https://openalex.org/W2036295233","https://openalex.org/W2036428644","https://openalex.org/W2058684026","https://openalex.org/W2096808475","https://openalex.org/W2099619765","https://openalex.org/W2120803666","https://openalex.org/W2144016135","https://openalex.org/W2159821363","https://openalex.org/W2486454569","https://openalex.org/W2594675857","https://openalex.org/W2610184543","https://openalex.org/W6734205086"],"related_works":["https://openalex.org/W2012842278","https://openalex.org/W2363207358","https://openalex.org/W1519398290","https://openalex.org/W4311853430","https://openalex.org/W2056851291","https://openalex.org/W2363789696","https://openalex.org/W2015799581","https://openalex.org/W2019501673","https://openalex.org/W2366740900","https://openalex.org/W2041392336"],"abstract_inverted_index":{"When":[0],"designing":[1],"an":[2],"ECG":[3,85,99],"monitoring":[4,37],"system":[5,38,114],"embedded":[6],"with":[7,72],"textile":[8,20],"electrodes":[9,21],"for":[10,39],"comfort,":[11],"it":[12],"is":[13],"challenging":[14],"to":[15,60,77,119],"ensure":[16],"reliable":[17],"monitoring,":[18],"because":[19],"suffer":[22],"from":[23],"motion":[24],"artifacts":[25],"and":[26,57,91,95,103,122],"incidental":[27],"poor":[28],"signal":[29],"quality.":[30],"For":[31],"the":[32,44,52,70,73,84,107,110,125,131],"design":[33,120,132],"of":[34,54,109,127],"a":[35,78],"comfortable":[36],"prematurely":[40],"born":[41],"babies":[42],"in":[43,69,130],"Neonatal":[45],"Intensive":[46],"Care":[47],"Unit":[48],"(NICU),":[49],"we":[50],"propose":[51],"concepts":[53],"'diversity":[55],"measurement'":[56],"'context":[58],"awareness'":[59],"improve":[61],"reliability.":[62],"Clinical":[63],"multi-modal":[64],"sensor":[65],"data":[66],"was":[67],"collected":[68],"NICU":[71],"Smart":[74],"Jacket":[75],"connected":[76],"state-of-the-art":[79],"amplifier.":[80],"We":[81],"found":[82,96],"that":[83],"signals":[86],"quality":[87],"varied":[88,92],"among":[89],"sensors":[90],"over":[93],"time,":[94],"correlations":[97],"between":[98],"signal,":[100],"acceleration":[101],"data,":[102],"context,":[104],"which":[105],"supports":[106],"feasibility":[108],"concepts.":[111],"Our":[112],"explorative":[113],"level":[115],"approach":[116],"has":[117],"lead":[118],"parameters":[121],"meta-insights":[123],"into":[124],"role":[126],"clinical":[128],"validation":[129],"process.":[133]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":4},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":2},{"year":2014,"cited_by_count":1}],"updated_date":"2026-04-04T16:13:02.066488","created_date":"2025-10-10T00:00:00"}
