{"id":"https://openalex.org/W2029107724","doi":"https://doi.org/10.1109/iembs.2011.6090414","title":"A mixed signal ECG processing platform with an adaptive sampling ADC for portable monitoring applications","display_name":"A mixed signal ECG processing platform with an adaptive sampling ADC for portable monitoring applications","publication_year":2011,"publication_date":"2011-08-01","ids":{"openalex":"https://openalex.org/W2029107724","doi":"https://doi.org/10.1109/iembs.2011.6090414","mag":"2029107724","pmid":"https://pubmed.ncbi.nlm.nih.gov/22254775"},"language":"en","primary_location":{"id":"doi:10.1109/iembs.2011.6090414","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iembs.2011.6090414","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101531645","display_name":"Hye Jung Kim","orcid":"https://orcid.org/0000-0002-7067-6810"},"institutions":[{"id":"https://openalex.org/I196972281","display_name":"Imec the Netherlands","ror":"https://ror.org/01ezq2j76","country_code":"NL","type":"facility","lineage":["https://openalex.org/I196972281"]},{"id":"https://openalex.org/I4210114974","display_name":"IMEC","ror":"https://ror.org/02kcbn207","country_code":"BE","type":"nonprofit","lineage":["https://openalex.org/I4210114974"]}],"countries":["BE","NL"],"is_corresponding":true,"raw_author_name":"Hyejung Kim","raw_affiliation_strings":["imec, Kapeldreef 75, 3000 Leuven, Belgium. hyejung@imec.be","imec, Kapeldreef 75, 3000 Leuven, Belgium"],"affiliations":[{"raw_affiliation_string":"imec, Kapeldreef 75, 3000 Leuven, Belgium. hyejung@imec.be","institution_ids":["https://openalex.org/I4210114974","https://openalex.org/I196972281"]},{"raw_affiliation_string":"imec, Kapeldreef 75, 3000 Leuven, Belgium","institution_ids":["https://openalex.org/I4210114974"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5078656907","display_name":"Chris Van Hoof","orcid":"https://orcid.org/0000-0002-4645-3326"},"institutions":[{"id":"https://openalex.org/I4210114974","display_name":"IMEC","ror":"https://ror.org/02kcbn207","country_code":"BE","type":"nonprofit","lineage":["https://openalex.org/I4210114974"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"C. Van Hoof","raw_affiliation_strings":["Imec, Leuven, Belgium","imec, Kapeldreef 75, 3000 Leuven, Belgium"],"affiliations":[{"raw_affiliation_string":"Imec, Leuven, Belgium","institution_ids":["https://openalex.org/I4210114974"]},{"raw_affiliation_string":"imec, Kapeldreef 75, 3000 Leuven, Belgium","institution_ids":["https://openalex.org/I4210114974"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5088562107","display_name":"Refet F\u0131rat Yaz\u0131c\u0131o\u011flu","orcid":null},"institutions":[{"id":"https://openalex.org/I4210114974","display_name":"IMEC","ror":"https://ror.org/02kcbn207","country_code":"BE","type":"nonprofit","lineage":["https://openalex.org/I4210114974"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"R. F. Yazicioglu","raw_affiliation_strings":["Imec, Leuven, Belgium","imec, Kapeldreef 75, 3000 Leuven, Belgium"],"affiliations":[{"raw_affiliation_string":"Imec, Leuven, Belgium","institution_ids":["https://openalex.org/I4210114974"]},{"raw_affiliation_string":"imec, Kapeldreef 75, 3000 Leuven, Belgium","institution_ids":["https://openalex.org/I4210114974"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5101531645"],"corresponding_institution_ids":["https://openalex.org/I196972281","https://openalex.org/I4210114974"],"apc_list":null,"apc_paid":null,"fwci":0.6296,"has_fulltext":false,"cited_by_count":16,"citation_normalized_percentile":{"value":0.69574137,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":"2011","issue":null,"first_page":"2196","last_page":"2199"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10323","display_name":"Analog and Mixed-Signal Circuit Design","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10323","display_name":"Analog and Mixed-Signal Circuit Design","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10363","display_name":"Low-power high-performance VLSI design","score":0.9936000108718872,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7338560223579407},{"id":"https://openalex.org/keywords/power-consumption","display_name":"Power consumption","score":0.7185714244842529},{"id":"https://openalex.org/keywords/sampling","display_name":"Sampling (signal processing)","score":0.6194901466369629},{"id":"https://openalex.org/keywords/signal","display_name":"SIGNAL (programming language)","score":0.5169224143028259},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.5063003301620483},{"id":"https://openalex.org/keywords/adaptive-sampling","display_name":"Adaptive sampling","score":0.4672432243824005},{"id":"https://openalex.org/keywords/signal-processing","display_name":"Signal processing","score":0.44857534766197205},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.44222408533096313},{"id":"https://openalex.org/keywords/computer-hardware","display_name":"Computer hardware","score":0.27932292222976685},{"id":"https://openalex.org/keywords/digital-signal-processing","display_name":"Digital signal processing","score":0.19378292560577393},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.10999494791030884},{"id":"https://openalex.org/keywords/detector","display_name":"Detector","score":0.0870707631111145},{"id":"https://openalex.org/keywords/statistics","display_name":"Statistics","score":0.07456392049789429},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.07446908950805664}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7338560223579407},{"id":"https://openalex.org/C2984118289","wikidata":"https://www.wikidata.org/wiki/Q29954","display_name":"Power consumption","level":3,"score":0.7185714244842529},{"id":"https://openalex.org/C140779682","wikidata":"https://www.wikidata.org/wiki/Q210868","display_name":"Sampling (signal processing)","level":3,"score":0.6194901466369629},{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.5169224143028259},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.5063003301620483},{"id":"https://openalex.org/C2781395549","wikidata":"https://www.wikidata.org/wiki/Q4680762","display_name":"Adaptive sampling","level":3,"score":0.4672432243824005},{"id":"https://openalex.org/C104267543","wikidata":"https://www.wikidata.org/wiki/Q208163","display_name":"Signal processing","level":3,"score":0.44857534766197205},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.44222408533096313},{"id":"https://openalex.org/C9390403","wikidata":"https://www.wikidata.org/wiki/Q3966","display_name":"Computer hardware","level":1,"score":0.27932292222976685},{"id":"https://openalex.org/C84462506","wikidata":"https://www.wikidata.org/wiki/Q173142","display_name":"Digital signal processing","level":2,"score":0.19378292560577393},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.10999494791030884},{"id":"https://openalex.org/C94915269","wikidata":"https://www.wikidata.org/wiki/Q1834857","display_name":"Detector","level":2,"score":0.0870707631111145},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.07456392049789429},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.07446908950805664},{"id":"https://openalex.org/C19499675","wikidata":"https://www.wikidata.org/wiki/Q232207","display_name":"Monte Carlo method","level":2,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000703","descriptor_name":"Analog-Digital Conversion","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000703","descriptor_name":"Analog-Digital Conversion","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000703","descriptor_name":"Analog-Digital Conversion","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D003936","descriptor_name":"Diagnosis, Computer-Assisted","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D003936","descriptor_name":"Diagnosis, Computer-Assisted","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D003936","descriptor_name":"Diagnosis, Computer-Assisted","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D004569","descriptor_name":"Electroencephalography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D004569","descriptor_name":"Electroencephalography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D004569","descriptor_name":"Electroencephalography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D013686","descriptor_name":"Telemetry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D013686","descriptor_name":"Telemetry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D013686","descriptor_name":"Telemetry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1109/iembs.2011.6090414","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iembs.2011.6090414","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","raw_type":"proceedings-article"},{"id":"pmid:22254775","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/22254775","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.8999999761581421,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":9,"referenced_works":["https://openalex.org/W1882885596","https://openalex.org/W2096948332","https://openalex.org/W2106669069","https://openalex.org/W2119667497","https://openalex.org/W2130056455","https://openalex.org/W2131675349","https://openalex.org/W2133433905","https://openalex.org/W2159318368","https://openalex.org/W6639275376"],"related_works":["https://openalex.org/W2038693912","https://openalex.org/W1991602789","https://openalex.org/W1582396021","https://openalex.org/W1988359706","https://openalex.org/W312558119","https://openalex.org/W4210985407","https://openalex.org/W2335441444","https://openalex.org/W138014004","https://openalex.org/W2075598034","https://openalex.org/W2984441180"],"abstract_inverted_index":{"This":[0,27],"paper":[1],"describes":[2],"a":[3,82],"mixed-signal":[4],"ECG":[5,32,57,74,92],"processing":[6,55],"platform":[7],"with":[8,34,59],"an":[9],"12-bit":[10],"ADC":[11,50],"architecture":[12],"that":[13,80],"can":[14],"adapt":[15],"its":[16],"sampling":[17,30,46],"rate":[18,24,38],"according":[19],"to":[20,101],"the":[21,29,49,54,65,69,73,89],"input":[22],"signals":[23,33,58,93],"of":[25,31,41,56,68],"change.":[26],"enables":[28,53],"significantly":[35],"reduced":[36],"data":[37],"without":[39],"loss":[40],"information.":[42],"The":[43,76],"presented":[44],"adaptive":[45],"scheme":[47],"reduces":[48,64],"power":[51,61,66,106],"consumption,":[52,62],"lower":[60],"and":[63,98],"consumption":[67],"radio":[70],"while":[71],"streaming":[72],"signals.":[75],"test":[77],"results":[78],"show":[79],"running":[81],"CWT-based":[83],"R":[84],"peak":[85],"detection":[86],"algorithm":[87],"using":[88],"adaptively":[90],"sampled":[91],"consumes":[94],"only":[95],"45.6":[96],"\u03bcW":[97],"it":[99],"leads":[100],"36%":[102],"less":[103],"overall":[104],"system":[105],"consumption.":[107]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":2},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":2},{"year":2016,"cited_by_count":2},{"year":2015,"cited_by_count":3},{"year":2013,"cited_by_count":1},{"year":2012,"cited_by_count":2}],"updated_date":"2026-01-13T01:12:25.745995","created_date":"2025-10-10T00:00:00"}
