{"id":"https://openalex.org/W2074814900","doi":"https://doi.org/10.1109/iembs.2011.6090316","title":"Noninvasive miniaturized mass-flow meter using a curved cannula for implantable axial flow blood pump","display_name":"Noninvasive miniaturized mass-flow meter using a curved cannula for implantable axial flow blood pump","publication_year":2011,"publication_date":"2011-08-01","ids":{"openalex":"https://openalex.org/W2074814900","doi":"https://doi.org/10.1109/iembs.2011.6090316","mag":"2074814900","pmid":"https://pubmed.ncbi.nlm.nih.gov/22254565"},"language":"en","primary_location":{"id":"doi:10.1109/iembs.2011.6090316","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iembs.2011.6090316","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5091100295","display_name":"Ryo Kosaka","orcid":"https://orcid.org/0000-0002-4658-6196"},"institutions":[{"id":"https://openalex.org/I73613424","display_name":"National Institute of Advanced Industrial Science and Technology","ror":"https://ror.org/01703db54","country_code":"JP","type":"government","lineage":["https://openalex.org/I73613424"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"R. Kosaka","raw_affiliation_strings":["National Institute of Advanced Industrial Science and Technology, 1-2-1, Namiki, Tsukuba, Ibaraki 305-8564, Japan. ryo.kosaka@aist.go.jp","National Institute of Advanced Industrial Science and Technology (AIST), 1-2-1 Namiki, Tsukuba, Ibaraki 305-8564, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Institute of Advanced Industrial Science and Technology, 1-2-1, Namiki, Tsukuba, Ibaraki 305-8564, Japan. ryo.kosaka@aist.go.jp","institution_ids":["https://openalex.org/I73613424"]},{"raw_affiliation_string":"National Institute of Advanced Industrial Science and Technology (AIST), 1-2-1 Namiki, Tsukuba, Ibaraki 305-8564, Japan","institution_ids":["https://openalex.org/I73613424"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5077204708","display_name":"Masahiro NISHIDA","orcid":"https://orcid.org/0000-0001-8075-2269"},"institutions":[{"id":"https://openalex.org/I73613424","display_name":"National Institute of Advanced Industrial Science and Technology","ror":"https://ror.org/01703db54","country_code":"JP","type":"government","lineage":["https://openalex.org/I73613424"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"M. Nishida","raw_affiliation_strings":["National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, Japan","National Institute of Advanced Industrial Science and Technology (AIST), 1-2-1 Namiki, Tsukuba, Ibaraki 305-8564, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, Japan","institution_ids":["https://openalex.org/I73613424"]},{"raw_affiliation_string":"National Institute of Advanced Industrial Science and Technology (AIST), 1-2-1 Namiki, Tsukuba, Ibaraki 305-8564, Japan","institution_ids":["https://openalex.org/I73613424"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5050566183","display_name":"Osamu Maruyama","orcid":"https://orcid.org/0000-0003-2484-5334"},"institutions":[{"id":"https://openalex.org/I73613424","display_name":"National Institute of Advanced Industrial Science and Technology","ror":"https://ror.org/01703db54","country_code":"JP","type":"government","lineage":["https://openalex.org/I73613424"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"O. Maruyama","raw_affiliation_strings":["National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, Japan","National Institute of Advanced Industrial Science and Technology (AIST), 1-2-1 Namiki, Tsukuba, Ibaraki 305-8564, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, Japan","institution_ids":["https://openalex.org/I73613424"]},{"raw_affiliation_string":"National Institute of Advanced Industrial Science and Technology (AIST), 1-2-1 Namiki, Tsukuba, Ibaraki 305-8564, Japan","institution_ids":["https://openalex.org/I73613424"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5101450913","display_name":"Takashi Yamane","orcid":"https://orcid.org/0000-0001-5053-5933"},"institutions":[{"id":"https://openalex.org/I73613424","display_name":"National Institute of Advanced Industrial Science and Technology","ror":"https://ror.org/01703db54","country_code":"JP","type":"government","lineage":["https://openalex.org/I73613424"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"T. Yamane","raw_affiliation_strings":["National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, Japan","National Institute of Advanced Industrial Science and Technology (AIST), 1-2-1 Namiki, Tsukuba, Ibaraki 305-8564, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, Japan","institution_ids":["https://openalex.org/I73613424"]},{"raw_affiliation_string":"National Institute of Advanced Industrial Science and Technology (AIST), 1-2-1 Namiki, Tsukuba, Ibaraki 305-8564, Japan","institution_ids":["https://openalex.org/I73613424"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I73613424"],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":"2011","issue":null,"first_page":"1343","last_page":"1346"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10675","display_name":"Mechanical Circulatory Support Devices","score":0.989300012588501,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10675","display_name":"Mechanical Circulatory Support Devices","score":0.989300012588501,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11249","display_name":"Wireless Power Transfer Systems","score":0.9860000014305115,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11372","display_name":"Hydraulic and Pneumatic Systems","score":0.9855999946594238,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/mass-flow-meter","display_name":"Mass flow meter","score":0.8068686723709106},{"id":"https://openalex.org/keywords/flow-measurement","display_name":"Flow measurement","score":0.6998008489608765},{"id":"https://openalex.org/keywords/thermal-mass-flow-meter","display_name":"Thermal mass flow meter","score":0.6210362315177917},{"id":"https://openalex.org/keywords/pulsatile-flow","display_name":"Pulsatile flow","score":0.6160727143287659},{"id":"https://openalex.org/keywords/cannula","display_name":"Cannula","score":0.6063625812530518},{"id":"https://openalex.org/keywords/ultrasonic-flow-meter","display_name":"Ultrasonic flow meter","score":0.5815384387969971},{"id":"https://openalex.org/keywords/magnetic-flow-meter","display_name":"Magnetic flow meter","score":0.5742035508155823},{"id":"https://openalex.org/keywords/mechanics","display_name":"Mechanics","score":0.5667427182197571},{"id":"https://openalex.org/keywords/volumetric-flow-rate","display_name":"Volumetric flow rate","score":0.5620640516281128},{"id":"https://openalex.org/keywords/strain-gauge","display_name":"Strain gauge","score":0.5404679775238037},{"id":"https://openalex.org/keywords/mass-flow","display_name":"Mass flow","score":0.5343562364578247},{"id":"https://openalex.org/keywords/mass-flow-rate","display_name":"Mass flow rate","score":0.49357879161834717},{"id":"https://openalex.org/keywords/positive-displacement-meter","display_name":"Positive displacement meter","score":0.4910757541656494},{"id":"https://openalex.org/keywords/flow","display_name":"Flow (mathematics)","score":0.4697692096233368},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.4620702862739563},{"id":"https://openalex.org/keywords/centrifugal-force","display_name":"Centrifugal force","score":0.44461870193481445},{"id":"https://openalex.org/keywords/blood-flow","display_name":"Blood flow","score":0.44053274393081665},{"id":"https://openalex.org/keywords/static-pressure","display_name":"Static pressure","score":0.4215850830078125},{"id":"https://openalex.org/keywords/pressure-measurement","display_name":"Pressure measurement","score":0.4189409017562866},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.35165584087371826},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.24238666892051697},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.22738605737686157},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.22397372126579285},{"id":"https://openalex.org/keywords/surgery","display_name":"Surgery","score":0.1384141445159912},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.1134779155254364},{"id":"https://openalex.org/keywords/composite-material","display_name":"Composite material","score":0.07627132534980774}],"concepts":[{"id":"https://openalex.org/C175580448","wikidata":"https://www.wikidata.org/wiki/Q114414","display_name":"Mass flow meter","level":3,"score":0.8068686723709106},{"id":"https://openalex.org/C16302685","wikidata":"https://www.wikidata.org/wiki/Q15091623","display_name":"Flow measurement","level":2,"score":0.6998008489608765},{"id":"https://openalex.org/C30198954","wikidata":"https://www.wikidata.org/wiki/Q4455290","display_name":"Thermal mass flow meter","level":4,"score":0.6210362315177917},{"id":"https://openalex.org/C79191276","wikidata":"https://www.wikidata.org/wiki/Q7259620","display_name":"Pulsatile flow","level":2,"score":0.6160727143287659},{"id":"https://openalex.org/C2778074680","wikidata":"https://www.wikidata.org/wiki/Q2125439","display_name":"Cannula","level":2,"score":0.6063625812530518},{"id":"https://openalex.org/C63066824","wikidata":"https://www.wikidata.org/wiki/Q2165466","display_name":"Ultrasonic flow meter","level":3,"score":0.5815384387969971},{"id":"https://openalex.org/C27805115","wikidata":"https://www.wikidata.org/wiki/Q960824","display_name":"Magnetic flow meter","level":3,"score":0.5742035508155823},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.5667427182197571},{"id":"https://openalex.org/C172120300","wikidata":"https://www.wikidata.org/wiki/Q1134348","display_name":"Volumetric flow rate","level":2,"score":0.5620640516281128},{"id":"https://openalex.org/C60584519","wikidata":"https://www.wikidata.org/wiki/Q610723","display_name":"Strain gauge","level":2,"score":0.5404679775238037},{"id":"https://openalex.org/C33493971","wikidata":"https://www.wikidata.org/wiki/Q3295893","display_name":"Mass flow","level":2,"score":0.5343562364578247},{"id":"https://openalex.org/C75892298","wikidata":"https://www.wikidata.org/wiki/Q1366187","display_name":"Mass flow rate","level":2,"score":0.49357879161834717},{"id":"https://openalex.org/C132643394","wikidata":"https://www.wikidata.org/wiki/Q7233264","display_name":"Positive displacement meter","level":2,"score":0.4910757541656494},{"id":"https://openalex.org/C38349280","wikidata":"https://www.wikidata.org/wiki/Q1434290","display_name":"Flow (mathematics)","level":2,"score":0.4697692096233368},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.4620702862739563},{"id":"https://openalex.org/C50735335","wikidata":"https://www.wikidata.org/wiki/Q178733","display_name":"Centrifugal force","level":3,"score":0.44461870193481445},{"id":"https://openalex.org/C158846371","wikidata":"https://www.wikidata.org/wiki/Q1642137","display_name":"Blood flow","level":2,"score":0.44053274393081665},{"id":"https://openalex.org/C158522163","wikidata":"https://www.wikidata.org/wiki/Q2406217","display_name":"Static pressure","level":2,"score":0.4215850830078125},{"id":"https://openalex.org/C80264047","wikidata":"https://www.wikidata.org/wiki/Q7424019","display_name":"Pressure measurement","level":2,"score":0.4189409017562866},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.35165584087371826},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.24238666892051697},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.22738605737686157},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.22397372126579285},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.1384141445159912},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.1134779155254364},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.07627132534980774},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.0},{"id":"https://openalex.org/C164705383","wikidata":"https://www.wikidata.org/wiki/Q10379","display_name":"Cardiology","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006353","descriptor_name":"Heart-Assist Devices","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D006353","descriptor_name":"Heart-Assist Devices","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D006353","descriptor_name":"Heart-Assist Devices","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D008904","descriptor_name":"Miniaturization","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008904","descriptor_name":"Miniaturization","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008904","descriptor_name":"Miniaturization","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012212","descriptor_name":"Rheology","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D012212","descriptor_name":"Rheology","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D012212","descriptor_name":"Rheology","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015918","descriptor_name":"Infusion Pumps, Implantable","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D015918","descriptor_name":"Infusion Pumps, Implantable","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D015918","descriptor_name":"Infusion Pumps, Implantable","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D017076","descriptor_name":"Computer-Aided Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017076","descriptor_name":"Computer-Aided Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017076","descriptor_name":"Computer-Aided Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D057785","descriptor_name":"Catheters","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D057785","descriptor_name":"Catheters","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D057785","descriptor_name":"Catheters","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1109/iembs.2011.6090316","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iembs.2011.6090316","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","raw_type":"proceedings-article"},{"id":"pmid:22254565","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/22254565","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G6026003635","display_name":"Development of hydrodynamic levitated centrifugal blood pump for long-term circulatory assist","funder_award_id":"21700479","funder_id":"https://openalex.org/F4320334764","funder_display_name":"Japan Society for the Promotion of Science"}],"funders":[{"id":"https://openalex.org/F4320334764","display_name":"Japan Society for the Promotion of Science","ror":"https://ror.org/00hhkn466"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":3,"referenced_works":["https://openalex.org/W1979552702","https://openalex.org/W2059978414","https://openalex.org/W2150163088"],"related_works":["https://openalex.org/W2913736001","https://openalex.org/W4244958415","https://openalex.org/W2038672343","https://openalex.org/W1673424278","https://openalex.org/W2906209913","https://openalex.org/W2016955966","https://openalex.org/W2079650474","https://openalex.org/W1965062187","https://openalex.org/W4231106027","https://openalex.org/W4386246496"],"abstract_inverted_index":{"Blood":[0],"flow":[1,32,164],"should":[2],"be":[3],"measured":[4,69,83],"to":[5,65,79,120,140,197],"monitor":[6],"conditions":[7],"of":[8],"patients":[9],"with":[10],"implantable":[11],"artificial":[12],"hearts":[13],"continuously":[14,201],"and":[15,72,75,130,162,181,202],"noninvasively.":[16,203],"We":[17,188],"have":[18],"developed":[19,192],"a":[20,26,114,146],"noninvasive":[21],"miniaturized":[22],"mass-flow":[23,36,44,91,193,199],"meter":[24,37,194],"using":[25,135],"curved":[27,48,67],"cannula":[28],"for":[29,86,106],"an":[30,131],"axial":[31],"blood":[33,137],"pump.":[34],"The":[35,90],"utilized":[38],"centrifugal":[39,73,160],"force":[40,109,161],"generated":[41],"by":[42,95,159],"the":[43,47,58,61,66,76,80,96,101,107,111,121,125,142,149,152,155,163,169,182,191],"rate":[45,92,165,200],"in":[46,98,148],"cannula.":[49],"Two":[50],"strain":[51],"gauges":[52],"served":[53],"as":[54],"sensors.":[55],"Based":[56],"on":[57],"numerical":[59,128,150],"analysis,":[60,151],"first":[62],"gauge,":[63],"attached":[64,78],"area,":[68,82],"static":[70,84,87],"pressure":[71,85,88,157],"force,":[74],"second,":[77],"straight":[81],"compensation.":[89],"was":[93,118,166,175,185,195],"determined":[94],"differences":[97],"output":[99],"from":[100],"two":[102],"gauges.":[103],"To":[104],"compensate":[105],"inertia":[108],"under":[110],"pulsatile":[112],"flow,":[113],"0.75-Hz":[115],"low-pass":[116],"filter":[117],"added":[119],"electrical":[122],"circuit.":[123],"In":[124,168],"evaluation":[126],"tests,":[127],"analysis":[129],"actual":[132,170],"measurement":[133,143,171,173],"test":[134],"bovine":[136],"were":[138],"performed":[139],"evaluate":[141],"performances.":[144],"As":[145],"result,":[147],"relationship":[153],"between":[154],"differential":[156],"caused":[158],"verified.":[167],"test,":[172],"error":[174],"less":[176],"than":[177],"\u00b1":[178],"0.5":[179],"L/min,":[180],"time":[183],"delay":[184],"0.12":[186],"s.":[187],"confirmed":[189],"that":[190],"able":[196],"measure":[198]},"counts_by_year":[],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
