{"id":"https://openalex.org/W1970736205","doi":"https://doi.org/10.1109/iembs.2011.6090194","title":"Diagnostic grade wireless ECG monitoring","display_name":"Diagnostic grade wireless ECG monitoring","publication_year":2011,"publication_date":"2011-08-01","ids":{"openalex":"https://openalex.org/W1970736205","doi":"https://doi.org/10.1109/iembs.2011.6090194","mag":"1970736205","pmid":"https://pubmed.ncbi.nlm.nih.gov/22254444"},"language":"en","primary_location":{"id":"doi:10.1109/iembs.2011.6090194","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iembs.2011.6090194","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5077524190","display_name":"Harinath Garudadri","orcid":"https://orcid.org/0000-0003-0456-0956"},"institutions":[{"id":"https://openalex.org/I19268510","display_name":"Qualcomm (United Kingdom)","ror":"https://ror.org/04d3djg48","country_code":"GB","type":"company","lineage":["https://openalex.org/I19268510","https://openalex.org/I4210087596"]},{"id":"https://openalex.org/I4210087596","display_name":"Qualcomm (United States)","ror":"https://ror.org/002zrf773","country_code":"US","type":"company","lineage":["https://openalex.org/I4210087596"]}],"countries":["GB","US"],"is_corresponding":true,"raw_author_name":"Harinath Garudadri","raw_affiliation_strings":["Qualcomm Research Center, 5775 Morehouse Dr, San Diego, CA 92121, USA. hgarudad@qualcomm.com","Qualcomm Research Center, 5775 Morehouse Dr., San Diego, CA, USA 92121"],"affiliations":[{"raw_affiliation_string":"Qualcomm Research Center, 5775 Morehouse Dr, San Diego, CA 92121, USA. hgarudad@qualcomm.com","institution_ids":["https://openalex.org/I4210087596","https://openalex.org/I19268510"]},{"raw_affiliation_string":"Qualcomm Research Center, 5775 Morehouse Dr., San Diego, CA, USA 92121","institution_ids":["https://openalex.org/I19268510"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5053809095","display_name":"Yuejie Chi","orcid":"https://orcid.org/0000-0002-6766-5459"},"institutions":[{"id":"https://openalex.org/I20089843","display_name":"Princeton University","ror":"https://ror.org/00hx57361","country_code":"US","type":"education","lineage":["https://openalex.org/I20089843"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Yuejie Chi","raw_affiliation_strings":["Department of Electrical Engineering, Princeton University, Princeton, NJ, USA","Department of Electrical Engineering Princeton University, Princeton, NJ 08540"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Princeton University, Princeton, NJ, USA","institution_ids":["https://openalex.org/I20089843"]},{"raw_affiliation_string":"Department of Electrical Engineering Princeton University, Princeton, NJ 08540","institution_ids":["https://openalex.org/I20089843"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5086155409","display_name":"Steve Baker","orcid":null},"institutions":[{"id":"https://openalex.org/I152058377","display_name":"Welch Allyn (United States)","ror":"https://ror.org/04dr1y470","country_code":"US","type":"company","lineage":["https://openalex.org/I152058377"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Steve Baker","raw_affiliation_strings":["Welch Allyn, Beaverton, OR, USA","Welch Allyn, 8500 SW Creekside Pl, Beaverton, OR, USA, 97008"],"affiliations":[{"raw_affiliation_string":"Welch Allyn, Beaverton, OR, USA","institution_ids":["https://openalex.org/I152058377"]},{"raw_affiliation_string":"Welch Allyn, 8500 SW Creekside Pl, Beaverton, OR, USA, 97008","institution_ids":["https://openalex.org/I152058377"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5070857594","display_name":"Somdeb Majumdar","orcid":null},"institutions":[{"id":"https://openalex.org/I4210087596","display_name":"Qualcomm (United States)","ror":"https://ror.org/002zrf773","country_code":"US","type":"company","lineage":["https://openalex.org/I4210087596"]},{"id":"https://openalex.org/I19268510","display_name":"Qualcomm (United Kingdom)","ror":"https://ror.org/04d3djg48","country_code":"GB","type":"company","lineage":["https://openalex.org/I19268510","https://openalex.org/I4210087596"]}],"countries":["GB","US"],"is_corresponding":false,"raw_author_name":"Somdeb Majumdar","raw_affiliation_strings":["Qualcomm Research Center, San Diego, CA, USA","Qualcomm Research Center, 5775 Morehouse Dr., San Diego, CA, USA 92121"],"affiliations":[{"raw_affiliation_string":"Qualcomm Research Center, San Diego, CA, USA","institution_ids":["https://openalex.org/I4210087596"]},{"raw_affiliation_string":"Qualcomm Research Center, 5775 Morehouse Dr., San Diego, CA, USA 92121","institution_ids":["https://openalex.org/I19268510"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5078248762","display_name":"Pawan K. Baheti","orcid":null},"institutions":[{"id":"https://openalex.org/I4210087596","display_name":"Qualcomm (United States)","ror":"https://ror.org/002zrf773","country_code":"US","type":"company","lineage":["https://openalex.org/I4210087596"]},{"id":"https://openalex.org/I19268510","display_name":"Qualcomm (United Kingdom)","ror":"https://ror.org/04d3djg48","country_code":"GB","type":"company","lineage":["https://openalex.org/I19268510","https://openalex.org/I4210087596"]}],"countries":["GB","US"],"is_corresponding":false,"raw_author_name":"Pawan K. Baheti","raw_affiliation_strings":["Qualcomm Research Center, San Diego, CA, USA","Qualcomm Research Center, 5775 Morehouse Dr., San Diego, CA, USA 92121"],"affiliations":[{"raw_affiliation_string":"Qualcomm Research Center, San Diego, CA, USA","institution_ids":["https://openalex.org/I4210087596"]},{"raw_affiliation_string":"Qualcomm Research Center, 5775 Morehouse Dr., San Diego, CA, USA 92121","institution_ids":["https://openalex.org/I19268510"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5040252577","display_name":"D. Ballard","orcid":null},"institutions":[{"id":"https://openalex.org/I152058377","display_name":"Welch Allyn (United States)","ror":"https://ror.org/04dr1y470","country_code":"US","type":"company","lineage":["https://openalex.org/I152058377"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Dan Ballard","raw_affiliation_strings":["Welch Allyn, Beaverton, OR, USA","Welch Allyn, 8500 SW Creekside Pl, Beaverton, OR, USA, 97008"],"affiliations":[{"raw_affiliation_string":"Welch Allyn, Beaverton, OR, USA","institution_ids":["https://openalex.org/I152058377"]},{"raw_affiliation_string":"Welch Allyn, 8500 SW Creekside Pl, Beaverton, OR, USA, 97008","institution_ids":["https://openalex.org/I152058377"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":6,"corresponding_author_ids":["https://openalex.org/A5077524190"],"corresponding_institution_ids":["https://openalex.org/I19268510","https://openalex.org/I4210087596"],"apc_list":null,"apc_paid":null,"fwci":0.3445,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.5969351,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"25","issue":null,"first_page":"850","last_page":"855"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10500","display_name":"Sparse and Compressive Sensing Techniques","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2206","display_name":"Computational Mechanics"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10500","display_name":"Sparse and Compressive Sensing Techniques","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2206","display_name":"Computational Mechanics"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10323","display_name":"Analog and Mixed-Signal Circuit Design","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11158","display_name":"Wireless Networks and Protocols","score":0.9979000091552734,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7482317686080933},{"id":"https://openalex.org/keywords/network-packet","display_name":"Network packet","score":0.5522977709770203},{"id":"https://openalex.org/keywords/wearable-computer","display_name":"Wearable computer","score":0.5129682421684265},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.5042327642440796},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.47487470507621765},{"id":"https://openalex.org/keywords/compressed-sensing","display_name":"Compressed sensing","score":0.4387246072292328},{"id":"https://openalex.org/keywords/wireless-sensor-network","display_name":"Wireless sensor network","score":0.4319372773170471},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.36829254031181335},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.21262788772583008},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.1308070421218872}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7482317686080933},{"id":"https://openalex.org/C158379750","wikidata":"https://www.wikidata.org/wiki/Q214111","display_name":"Network packet","level":2,"score":0.5522977709770203},{"id":"https://openalex.org/C150594956","wikidata":"https://www.wikidata.org/wiki/Q1334829","display_name":"Wearable computer","level":2,"score":0.5129682421684265},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.5042327642440796},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.47487470507621765},{"id":"https://openalex.org/C124851039","wikidata":"https://www.wikidata.org/wiki/Q2665459","display_name":"Compressed sensing","level":2,"score":0.4387246072292328},{"id":"https://openalex.org/C24590314","wikidata":"https://www.wikidata.org/wiki/Q336038","display_name":"Wireless sensor network","level":2,"score":0.4319372773170471},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.36829254031181335},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.21262788772583008},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.1308070421218872},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D001145","descriptor_name":"Arrhythmias, Cardiac","qualifier_ui":"Q000175","qualifier_name":"diagnosis","is_major_topic":false},{"descriptor_ui":"D001145","descriptor_name":"Arrhythmias, Cardiac","qualifier_ui":"Q000175","qualifier_name":"diagnosis","is_major_topic":false},{"descriptor_ui":"D001145","descriptor_name":"Arrhythmias, Cardiac","qualifier_ui":"Q000175","qualifier_name":"diagnosis","is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D013686","descriptor_name":"Telemetry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D013686","descriptor_name":"Telemetry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D013686","descriptor_name":"Telemetry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015716","descriptor_name":"Electrocardiography, Ambulatory","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D015716","descriptor_name":"Electrocardiography, Ambulatory","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D015716","descriptor_name":"Electrocardiography, Ambulatory","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D016477","descriptor_name":"Artifacts","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D016477","descriptor_name":"Artifacts","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D016477","descriptor_name":"Artifacts","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D017216","descriptor_name":"Telemedicine","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D017216","descriptor_name":"Telemedicine","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D017216","descriptor_name":"Telemedicine","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1109/iembs.2011.6090194","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iembs.2011.6090194","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","raw_type":"proceedings-article"},{"id":"pmid:22254444","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/22254444","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.4000000059604645,"display_name":"Good health and well-being","id":"https://metadata.un.org/sdg/3"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":17,"referenced_works":["https://openalex.org/W1654257729","https://openalex.org/W2001199719","https://openalex.org/W2005186928","https://openalex.org/W2041651212","https://openalex.org/W2109357213","https://openalex.org/W2109449402","https://openalex.org/W2115549875","https://openalex.org/W2124878593","https://openalex.org/W2128659236","https://openalex.org/W2160172035","https://openalex.org/W2164452299","https://openalex.org/W2170883315","https://openalex.org/W2296616510","https://openalex.org/W4250955649","https://openalex.org/W4320406025","https://openalex.org/W6661043511","https://openalex.org/W6677446445"],"related_works":["https://openalex.org/W2158224665","https://openalex.org/W2379589510","https://openalex.org/W4300044672","https://openalex.org/W2810730439","https://openalex.org/W1881631164","https://openalex.org/W2358292267","https://openalex.org/W2378166785","https://openalex.org/W2383801459","https://openalex.org/W2545256787","https://openalex.org/W4233785208"],"abstract_inverted_index":{"In":[0,76,204],"remote":[1,72],"monitoring":[2,73],"of":[3,16,52,74,122,134,177,213],"Electrocardiogram":[4],"(ECG),":[5],"it":[6],"is":[7,18,28,183],"very":[8],"important":[9,30],"to":[10,34,39,84,88,95],"ensure":[11],"that":[12,172],"the":[13,32,62,126,131,135,164,206,211],"diagnostic":[14,70,132],"integrity":[15,133],"signals":[17],"not":[19],"compromised":[20],"by":[21,91,163],"sensing":[22],"artifacts":[23],"and":[24,44,99,148,156,166,174,195],"channel":[25],"errors.":[26],"It":[27],"also":[29],"for":[31,65,192,219],"sensors":[33,68],"be":[35],"extremely":[36],"power":[37],"efficient":[38,119],"enable":[40],"wearable":[41],"form":[42],"factors":[43],"long":[45],"battery":[46],"life.":[47],"We":[48,142,170],"present":[49,117],"an":[50,57,82,118],"application":[51,63],"Compressive":[53],"Sensing":[54],"(CS)":[55],"as":[56,223],"error":[58,215],"mitigation":[59,191,216],"scheme":[60],"at":[61,125,199],"layer":[64],"wearable,":[66],"wireless":[67],"in":[69,110,210],"grade":[71],"ECG.":[75],"our":[77,144],"previous":[78],"work,":[79],"we":[80,116,129],"described":[81],"approach":[83,145],"mitigate":[85],"errors":[86],"due":[87],"packet":[89,139,189,201],"losses":[90],"projecting":[92],"ECG":[93,137,180],"data":[94],"a":[96,101,178],"random":[97,123],"space":[98],"recovering":[100],"faithful":[102],"representation":[103],"using":[104,159],"sparse":[105],"reconstruction":[106],"methods.":[107],"Our":[108],"contributions":[109],"this":[111],"work":[112],"are":[113],"twofold.":[114],"First,":[115],"hardware":[120],"implementation":[121],"projection":[124],"sensor.":[127],"Second,":[128],"validate":[130,143],"reconstructed":[136],"after":[138],"loss":[140,190,202],"mitigation.":[141],"on":[146],"MIT":[147],"AHA":[149],"databases":[150],"comprising":[151],"more":[152],"than":[153],"250,000":[154],"normal":[155,194],"abnormal":[157,196,220],"beats":[158,197,221],"EC57":[160],"protocols":[161],"adopted":[162],"Food":[165],"Drug":[167],"Administration":[168],"(FDA).":[169],"show":[171],"sensitivity":[173],"positive":[175],"predictivity":[176],"state-of-the-art":[179],"arrhythmia":[181],"classifier":[182],"essentially":[184],"invariant":[185],"under":[186],"CS":[187],"based":[188],"both":[193],"even":[198],"high":[200],"rates.":[203],"contrast,":[205],"performance":[207],"degrades":[208],"significantly":[209],"absence":[212],"any":[214],"scheme,":[217],"particularly":[218],"such":[222],"Ventricular":[224],"Ectopic":[225],"Beats":[226],"(VEB).":[227]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2014,"cited_by_count":1}],"updated_date":"2026-01-13T01:12:25.745995","created_date":"2025-10-10T00:00:00"}
