{"id":"https://openalex.org/W1994402112","doi":"https://doi.org/10.1109/iembs.2011.6089889","title":"Analysis of integrated optofluidic lab-on-a-chip fluorescence biosensor based on transmittance of light through a fluidic gap","display_name":"Analysis of integrated optofluidic lab-on-a-chip fluorescence biosensor based on transmittance of light through a fluidic gap","publication_year":2011,"publication_date":"2011-08-01","ids":{"openalex":"https://openalex.org/W1994402112","doi":"https://doi.org/10.1109/iembs.2011.6089889","mag":"1994402112","pmid":"https://pubmed.ncbi.nlm.nih.gov/22254243"},"language":"en","primary_location":{"id":"doi:10.1109/iembs.2011.6089889","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iembs.2011.6089889","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Narayan Krishnaswamy","orcid":null},"institutions":[{"id":"https://openalex.org/I288496929","display_name":"Narayana Health","ror":"https://ror.org/05kx1ke03","country_code":"IN","type":"healthcare","lineage":["https://openalex.org/I288496929"]},{"id":"https://openalex.org/I59270414","display_name":"Indian Institute of Science Bangalore","ror":"https://ror.org/04dese585","country_code":"IN","type":"education","lineage":["https://openalex.org/I59270414"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"Narayan Krishnaswamy","raw_affiliation_strings":["Department of Instrumentation and Applied Physics, Institute of Science, Bangalore 560012, India. narayank@airtelmail.in","Department of Instrumentation and Applied physics, Indian Institute of Science, Bangalore-560012, India"],"affiliations":[{"raw_affiliation_string":"Department of Instrumentation and Applied Physics, Institute of Science, Bangalore 560012, India. narayank@airtelmail.in","institution_ids":["https://openalex.org/I288496929"]},{"raw_affiliation_string":"Department of Instrumentation and Applied physics, Indian Institute of Science, Bangalore-560012, India","institution_ids":["https://openalex.org/I59270414"]}]},{"author_position":"middle","author":{"id":null,"display_name":"T. Srinivas","orcid":null},"institutions":[{"id":"https://openalex.org/I59270414","display_name":"Indian Institute of Science Bangalore","ror":"https://ror.org/04dese585","country_code":"IN","type":"education","lineage":["https://openalex.org/I59270414"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"T. Srinivas","raw_affiliation_strings":["Department of Electrical and Communication Engineering, Indian Institute of Science, Bangalore, India","Department of Electrical and Communication Engineering, Indian Institute of Science, Bangalore, 560012, India"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Communication Engineering, Indian Institute of Science, Bangalore, India","institution_ids":["https://openalex.org/I59270414"]},{"raw_affiliation_string":"Department of Electrical and Communication Engineering, Indian Institute of Science, Bangalore, 560012, India","institution_ids":["https://openalex.org/I59270414"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5111483140","display_name":"G. Mohan Rao","orcid":null},"institutions":[{"id":"https://openalex.org/I59270414","display_name":"Indian Institute of Science Bangalore","ror":"https://ror.org/04dese585","country_code":"IN","type":"education","lineage":["https://openalex.org/I59270414"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"G. Mohan Rao","raw_affiliation_strings":["Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore, India","Department of Instrumentation and Applied physics, Indian Institute of Science, Bangalore-560012, India"],"affiliations":[{"raw_affiliation_string":"Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore, India","institution_ids":["https://openalex.org/I59270414"]},{"raw_affiliation_string":"Department of Instrumentation and Applied physics, Indian Institute of Science, Bangalore-560012, India","institution_ids":["https://openalex.org/I59270414"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I288496929","https://openalex.org/I59270414"],"apc_list":null,"apc_paid":null,"fwci":0.8105,"has_fulltext":false,"cited_by_count":6,"citation_normalized_percentile":{"value":0.75090831,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":95},"biblio":{"volume":"2011","issue":null,"first_page":"30","last_page":"34"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12452","display_name":"Electrowetting and Microfluidic Technologies","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12452","display_name":"Electrowetting and Microfluidic Technologies","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10412","display_name":"Microfluidic and Capillary Electrophoresis Applications","score":0.9983999729156494,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11472","display_name":"Analytical Chemistry and Sensors","score":0.9977999925613403,"subfield":{"id":"https://openalex.org/subfields/1502","display_name":"Bioengineering"},"field":{"id":"https://openalex.org/fields/15","display_name":"Chemical Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fluidics","display_name":"Fluidics","score":0.9276095628738403},{"id":"https://openalex.org/keywords/biosensor","display_name":"Biosensor","score":0.8568905591964722},{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.7059588432312012},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.6572544574737549},{"id":"https://openalex.org/keywords/refractive-index","display_name":"Refractive index","score":0.6109806299209595},{"id":"https://openalex.org/keywords/chip","display_name":"Chip","score":0.5863611698150635},{"id":"https://openalex.org/keywords/fluorescence","display_name":"Fluorescence","score":0.556159496307373},{"id":"https://openalex.org/keywords/lab-on-a-chip","display_name":"Lab-on-a-chip","score":0.5229942798614502},{"id":"https://openalex.org/keywords/optoelectronics","display_name":"Optoelectronics","score":0.5108282566070557},{"id":"https://openalex.org/keywords/transmittance","display_name":"Transmittance","score":0.4911806285381317},{"id":"https://openalex.org/keywords/microfluidics","display_name":"Microfluidics","score":0.4650600552558899},{"id":"https://openalex.org/keywords/coupling","display_name":"Coupling (piping)","score":0.45307138562202454},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.38148823380470276},{"id":"https://openalex.org/keywords/nanotechnology","display_name":"Nanotechnology","score":0.3295358419418335},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.15561842918395996},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.113366037607193},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.0987713634967804},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.06367996335029602},{"id":"https://openalex.org/keywords/composite-material","display_name":"Composite material","score":0.05439820885658264}],"concepts":[{"id":"https://openalex.org/C132651336","wikidata":"https://www.wikidata.org/wiki/Q185571","display_name":"Fluidics","level":2,"score":0.9276095628738403},{"id":"https://openalex.org/C160756335","wikidata":"https://www.wikidata.org/wiki/Q669391","display_name":"Biosensor","level":2,"score":0.8568905591964722},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.7059588432312012},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.6572544574737549},{"id":"https://openalex.org/C42067758","wikidata":"https://www.wikidata.org/wiki/Q174102","display_name":"Refractive index","level":2,"score":0.6109806299209595},{"id":"https://openalex.org/C165005293","wikidata":"https://www.wikidata.org/wiki/Q1074500","display_name":"Chip","level":2,"score":0.5863611698150635},{"id":"https://openalex.org/C91881484","wikidata":"https://www.wikidata.org/wiki/Q191807","display_name":"Fluorescence","level":2,"score":0.556159496307373},{"id":"https://openalex.org/C138942068","wikidata":"https://www.wikidata.org/wiki/Q633261","display_name":"Lab-on-a-chip","level":3,"score":0.5229942798614502},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.5108282566070557},{"id":"https://openalex.org/C150493377","wikidata":"https://www.wikidata.org/wiki/Q1427863","display_name":"Transmittance","level":2,"score":0.4911806285381317},{"id":"https://openalex.org/C8673954","wikidata":"https://www.wikidata.org/wiki/Q138845","display_name":"Microfluidics","level":2,"score":0.4650600552558899},{"id":"https://openalex.org/C131584629","wikidata":"https://www.wikidata.org/wiki/Q4308705","display_name":"Coupling (piping)","level":2,"score":0.45307138562202454},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.38148823380470276},{"id":"https://openalex.org/C171250308","wikidata":"https://www.wikidata.org/wiki/Q11468","display_name":"Nanotechnology","level":1,"score":0.3295358419418335},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.15561842918395996},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.113366037607193},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0987713634967804},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.06367996335029602},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.05439820885658264}],"mesh":[{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008027","descriptor_name":"Light","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008027","descriptor_name":"Light","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008027","descriptor_name":"Light","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012542","descriptor_name":"Scattering, Radiation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012542","descriptor_name":"Scattering, Radiation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012542","descriptor_name":"Scattering, Radiation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013050","descriptor_name":"Spectrometry, Fluorescence","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D013050","descriptor_name":"Spectrometry, Fluorescence","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D013050","descriptor_name":"Spectrometry, Fluorescence","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015374","descriptor_name":"Biosensing Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D015374","descriptor_name":"Biosensing Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D015374","descriptor_name":"Biosensing Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D017076","descriptor_name":"Computer-Aided Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017076","descriptor_name":"Computer-Aided Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017076","descriptor_name":"Computer-Aided Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D018511","descriptor_name":"Systems Integration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D018511","descriptor_name":"Systems Integration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D018511","descriptor_name":"Systems Integration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D046210","descriptor_name":"Microfluidic Analytical Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D046210","descriptor_name":"Microfluidic Analytical Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D046210","descriptor_name":"Microfluidic Analytical Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D055096","descriptor_name":"Optical Devices","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D055096","descriptor_name":"Optical Devices","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D055096","descriptor_name":"Optical Devices","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true}],"locations_count":3,"locations":[{"id":"doi:10.1109/iembs.2011.6089889","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iembs.2011.6089889","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","raw_type":"proceedings-article"},{"id":"pmid:22254243","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/22254243","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","raw_type":null},{"id":"pmh:oai:eprints.iisc.ac.in:42875","is_oa":false,"landing_page_url":null,"pdf_url":null,"source":{"id":"https://openalex.org/S4377196309","display_name":"NOT FOUND REPOSITORY (Indian Institute of Science Bangalore)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I59270414","host_organization_name":"Indian Institute of Science Bangalore","host_organization_lineage":["https://openalex.org/I59270414"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"acceptedVersion","is_accepted":true,"is_published":false,"raw_source_name":"","raw_type":"Conference Paper"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.6800000071525574}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W151505382","https://openalex.org/W634550604","https://openalex.org/W1994865849","https://openalex.org/W2026242786","https://openalex.org/W2039423915","https://openalex.org/W2054660699","https://openalex.org/W2056141407","https://openalex.org/W2059393086","https://openalex.org/W2081657728","https://openalex.org/W2102153609","https://openalex.org/W2121988986","https://openalex.org/W4237307182"],"related_works":["https://openalex.org/W2046430340","https://openalex.org/W4385923988","https://openalex.org/W130619353","https://openalex.org/W2808489040","https://openalex.org/W2055686434","https://openalex.org/W2939039077","https://openalex.org/W2021085378","https://openalex.org/W4298071810","https://openalex.org/W2733260917","https://openalex.org/W2185392992"],"abstract_inverted_index":{"Sensitivity":[0],"analysis":[1],"is":[2,32,59,67],"an":[3,35],"important":[4],"aspect":[5],"to":[6,42],"be":[7,19,50],"looked":[8],"into":[9],"while":[10],"designing":[11],"lab-on-a-chip":[12],"systems.":[13],"In":[14],"this":[15],"paper":[16],"we":[17],"will":[18,49],"showing":[20,52],"with":[21],"appropriate":[22],"design":[23],"that":[24,53],"the":[25,29,54,57,72,80],"best":[26],"sensitivity":[27,55],"of":[28,38,56,63,74,79],"fluorescence":[30],"biosensor":[31,58],"achieved":[33],"for":[34],"optimal":[36],"width":[37,73],"fluidic":[39,75],"gap,":[40,76],"corresponding":[41],"a":[43],"particular":[44],"mode":[45],"spot":[46],"size.":[47],"We":[48],"also":[51],"affected":[60],"by":[61,69],"efficiency":[62],"light":[64],"coupling,":[65],"which":[66],"influenced":[68],"changes":[70],"in":[71],"refractive":[77],"index":[78],"fluid":[81],"and":[82],"higher":[83],"order":[84],"modes.":[85]},"counts_by_year":[{"year":2021,"cited_by_count":2},{"year":2019,"cited_by_count":1},{"year":2014,"cited_by_count":1},{"year":2013,"cited_by_count":1},{"year":2012,"cited_by_count":1}],"updated_date":"2026-04-16T08:26:57.006410","created_date":"2025-10-10T00:00:00"}
