{"id":"https://openalex.org/W4415968908","doi":"https://doi.org/10.1109/iecon58223.2025.11221658","title":"Retrieved Braking Energy in the Tram Way Via Electric Vehicle Chargers","display_name":"Retrieved Braking Energy in the Tram Way Via Electric Vehicle Chargers","publication_year":2025,"publication_date":"2025-10-14","ids":{"openalex":"https://openalex.org/W4415968908","doi":"https://doi.org/10.1109/iecon58223.2025.11221658"},"language":null,"primary_location":{"id":"doi:10.1109/iecon58223.2025.11221658","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon58223.2025.11221658","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2025 \u2013 51st Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5051204290","display_name":"Adnan Ahmad Khan","orcid":"https://orcid.org/0000-0002-3816-3943"},"institutions":[{"id":"https://openalex.org/I177477856","display_name":"Polytechnic University of Turin","ror":"https://ror.org/00bgk9508","country_code":"IT","type":"education","lineage":["https://openalex.org/I177477856"]}],"countries":["IT"],"is_corresponding":true,"raw_author_name":"Adnan Khan","raw_affiliation_strings":["Politecnico di Torino,Department of Energy,Torino,Italy"],"affiliations":[{"raw_affiliation_string":"Politecnico di Torino,Department of Energy,Torino,Italy","institution_ids":["https://openalex.org/I177477856"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5028689934","display_name":"Paolo Guglielmi","orcid":"https://orcid.org/0000-0002-5452-8869"},"institutions":[{"id":"https://openalex.org/I177477856","display_name":"Polytechnic University of Turin","ror":"https://ror.org/00bgk9508","country_code":"IT","type":"education","lineage":["https://openalex.org/I177477856"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Paolo Guglielmi","raw_affiliation_strings":["Politecnico di Torino,Department of Energy,Torino,Italy"],"affiliations":[{"raw_affiliation_string":"Politecnico di Torino,Department of Energy,Torino,Italy","institution_ids":["https://openalex.org/I177477856"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5017372932","display_name":"Enrico Pons","orcid":"https://orcid.org/0000-0001-9391-4108"},"institutions":[{"id":"https://openalex.org/I177477856","display_name":"Polytechnic University of Turin","ror":"https://ror.org/00bgk9508","country_code":"IT","type":"education","lineage":["https://openalex.org/I177477856"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Enrico Pons","raw_affiliation_strings":["Politecnico di Torino,Department of Energy,Torino,Italy"],"affiliations":[{"raw_affiliation_string":"Politecnico di Torino,Department of Energy,Torino,Italy","institution_ids":["https://openalex.org/I177477856"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5076682493","display_name":"Roberto Re","orcid":"https://orcid.org/0000-0002-6196-7843"},"institutions":[{"id":"https://openalex.org/I177477856","display_name":"Polytechnic University of Turin","ror":"https://ror.org/00bgk9508","country_code":"IT","type":"education","lineage":["https://openalex.org/I177477856"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Roberto Re","raw_affiliation_strings":["Politecnico di Torino,Department of Energy,Torino,Italy"],"affiliations":[{"raw_affiliation_string":"Politecnico di Torino,Department of Energy,Torino,Italy","institution_ids":["https://openalex.org/I177477856"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5093969802","display_name":"Alfredo Felix Cota","orcid":null},"institutions":[{"id":"https://openalex.org/I177477856","display_name":"Polytechnic University of Turin","ror":"https://ror.org/00bgk9508","country_code":"IT","type":"education","lineage":["https://openalex.org/I177477856"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Alfredo Felix Cota","raw_affiliation_strings":["Politecnico di Torino,Department of Energy,Torino,Italy"],"affiliations":[{"raw_affiliation_string":"Politecnico di Torino,Department of Energy,Torino,Italy","institution_ids":["https://openalex.org/I177477856"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5051204290"],"corresponding_institution_ids":["https://openalex.org/I177477856"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.47901475,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11568","display_name":"Railway Systems and Energy Efficiency","score":0.9901000261306763,"subfield":{"id":"https://openalex.org/subfields/2209","display_name":"Industrial and Manufacturing Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11568","display_name":"Railway Systems and Energy Efficiency","score":0.9901000261306763,"subfield":{"id":"https://openalex.org/subfields/2209","display_name":"Industrial and Manufacturing Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10768","display_name":"Electric Vehicles and Infrastructure","score":0.0017999999690800905,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10808","display_name":"Electric and Hybrid Vehicle Technologies","score":0.0017999999690800905,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/regenerative-brake","display_name":"Regenerative brake","score":0.8120999932289124},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.4950000047683716},{"id":"https://openalex.org/keywords/energy-storage","display_name":"Energy storage","score":0.4867999851703644},{"id":"https://openalex.org/keywords/electric-vehicle","display_name":"Electric vehicle","score":0.48510000109672546},{"id":"https://openalex.org/keywords/train","display_name":"Train","score":0.4390000104904175},{"id":"https://openalex.org/keywords/rectifier","display_name":"Rectifier (neural networks)","score":0.43050000071525574},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.41040000319480896},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.4065999984741211},{"id":"https://openalex.org/keywords/energy-recovery","display_name":"Energy recovery","score":0.38519999384880066},{"id":"https://openalex.org/keywords/energy-flow","display_name":"Energy flow","score":0.3666999936103821}],"concepts":[{"id":"https://openalex.org/C162380856","wikidata":"https://www.wikidata.org/wiki/Q580078","display_name":"Regenerative brake","level":3,"score":0.8120999932289124},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.6664999723434448},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.4950000047683716},{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.4867999851703644},{"id":"https://openalex.org/C2776422217","wikidata":"https://www.wikidata.org/wiki/Q13629441","display_name":"Electric vehicle","level":3,"score":0.48510000109672546},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.477400004863739},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4560000002384186},{"id":"https://openalex.org/C190839683","wikidata":"https://www.wikidata.org/wiki/Q2448197","display_name":"Train","level":2,"score":0.4390000104904175},{"id":"https://openalex.org/C50100734","wikidata":"https://www.wikidata.org/wiki/Q7303176","display_name":"Rectifier (neural networks)","level":5,"score":0.43050000071525574},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.41040000319480896},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.4065999984741211},{"id":"https://openalex.org/C141675481","wikidata":"https://www.wikidata.org/wiki/Q3588981","display_name":"Energy recovery","level":3,"score":0.38519999384880066},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3763999938964844},{"id":"https://openalex.org/C206815995","wikidata":"https://www.wikidata.org/wiki/Q1341307","display_name":"Energy flow","level":3,"score":0.3666999936103821},{"id":"https://openalex.org/C117896860","wikidata":"https://www.wikidata.org/wiki/Q11376","display_name":"Acceleration","level":2,"score":0.34860000014305115},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.3384000062942505},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.3239000141620636},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.311599999666214},{"id":"https://openalex.org/C67172668","wikidata":"https://www.wikidata.org/wiki/Q622756","display_name":"Electricity meter","level":3,"score":0.30559998750686646},{"id":"https://openalex.org/C158549904","wikidata":"https://www.wikidata.org/wiki/Q1155327","display_name":"Dynamic braking","level":3,"score":0.29829999804496765},{"id":"https://openalex.org/C520301825","wikidata":"https://www.wikidata.org/wiki/Q380170","display_name":"Energy conservation","level":2,"score":0.28619998693466187},{"id":"https://openalex.org/C30905978","wikidata":"https://www.wikidata.org/wiki/Q815598","display_name":"Metering mode","level":2,"score":0.28610000014305115},{"id":"https://openalex.org/C98576551","wikidata":"https://www.wikidata.org/wiki/Q841798","display_name":"Electric potential energy","level":3,"score":0.2840000092983246},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.2838999927043915},{"id":"https://openalex.org/C110069716","wikidata":"https://www.wikidata.org/wiki/Q1076882","display_name":"Battery electric vehicle","level":4,"score":0.2822999954223633},{"id":"https://openalex.org/C2779960059","wikidata":"https://www.wikidata.org/wiki/Q7113681","display_name":"Overhead (engineering)","level":2,"score":0.2809000015258789},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.2736000120639801},{"id":"https://openalex.org/C2779607880","wikidata":"https://www.wikidata.org/wiki/Q2140665","display_name":"Charging station","level":4,"score":0.271699994802475},{"id":"https://openalex.org/C22762622","wikidata":"https://www.wikidata.org/wiki/Q628904","display_name":"Operating point","level":2,"score":0.26179999113082886},{"id":"https://openalex.org/C198352243","wikidata":"https://www.wikidata.org/wiki/Q37105","display_name":"Line (geometry)","level":2,"score":0.25999999046325684},{"id":"https://openalex.org/C2781260460","wikidata":"https://www.wikidata.org/wiki/Q6139999","display_name":"Energy management system","level":4,"score":0.25940001010894775},{"id":"https://openalex.org/C125209513","wikidata":"https://www.wikidata.org/wiki/Q4037520","display_name":"Doors","level":2,"score":0.2565000057220459},{"id":"https://openalex.org/C423512","wikidata":"https://www.wikidata.org/wiki/Q383973","display_name":"Electricity generation","level":3,"score":0.25609999895095825},{"id":"https://openalex.org/C28719098","wikidata":"https://www.wikidata.org/wiki/Q44946","display_name":"Point (geometry)","level":2,"score":0.25049999356269836}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon58223.2025.11221658","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon58223.2025.11221658","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2025 \u2013 51st Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W1579147082","https://openalex.org/W1964895553","https://openalex.org/W1981582118","https://openalex.org/W2022951168","https://openalex.org/W2043342849","https://openalex.org/W2094590413","https://openalex.org/W2140426998","https://openalex.org/W2386204094","https://openalex.org/W2514997675","https://openalex.org/W2562112749","https://openalex.org/W2573655116","https://openalex.org/W2789282845","https://openalex.org/W2950489071","https://openalex.org/W4211164111"],"related_works":[],"abstract_inverted_index":{"Regenerative":[0],"braking":[1,82,168],"of":[2,8,16,124,142,197,221,249,254],"trains":[3],"is":[4,121],"a":[5,47,68,72,102,189,239,278],"crucial":[6],"method":[7],"harnessing":[9],"energy,":[10],"significantly":[11],"improving":[12],"the":[13,28,59,80,89,125,129,139,143,165,174,184,193,198,207,211,215,222,250,258,262],"overall":[14,194],"efficiency":[15,253],"DC":[17,126,136,147,263],"networks":[18],"by":[19,85,230],"repurposing":[20],"energy":[21,43,57,83,162,195,208,223,255,274],"during":[22,167],"acceleration":[23],"or":[24,180],"returning":[25],"it":[26],"to":[27,35,55,58,78,137,153,183,205,277],"grid.":[29],"Various":[30],"strategies":[31],"have":[32],"been":[33],"developed":[34],"optimize":[36],"this":[37],"process,":[38],"including":[39],"on-board":[40],"and":[41,214,225,257,281],"off-board":[42],"storage":[44],"systems":[45,53,187],"using":[46,71,236],"third":[48],"rail,":[49],"as":[50,52,101],"well":[51],"designed":[54],"return":[56],"overhead":[60],"line":[61],"via":[62],"pantographs.":[63],"This":[64,146,242],"paper":[65],"focuses":[66],"on":[67,261,271],"detailed":[69,219],"analysis":[70],"40kWh":[73],"Electric":[74],"Vehicle":[75],"(EV)":[76],"charger":[77,176],"evaluate":[79],"regenerative":[81,273],"produced":[84],"trams":[86,112,166],"operating":[87],"at":[88,114],"Caio":[90],"Mario":[91],"Park":[92],"Tram":[93],"Station":[94],"in":[95],"Torino,":[96],"Italy.":[97],"The":[98,161,227,266],"station":[99],"serves":[100],"vital":[103],"connection":[104],"point":[105],"for":[106,177,238,245],"two":[107,212],"primary":[108],"zones,":[109,155],"where":[110],"multiple":[111],"operate":[113],"varying":[115],"intervals.":[116],"An":[117],"AC-DC":[118],"12-pulse":[119],"rectifier":[120],"installed":[122,204],"upstream":[123],"bus-bar,":[127],"converting":[128],"22kV":[130],"three-phase":[131],"AC":[132],"power":[133,152],"into":[134,173],"600V":[135],"match":[138],"operational":[140],"voltage":[141],"tram":[144,283],"system.":[145],"bus-bar":[148],"not":[149],"only":[150],"supplies":[151],"both":[154],"but":[156],"also":[157],"supports":[158],"EV":[159,175,216],"chargers.":[160],"recovered":[163],"from":[164],"can":[169],"be":[170],"channeled":[171],"directly":[172],"vehicle":[178],"recharging":[179],"routed":[181],"back":[182],"grid\u2019s":[185,264],"auxiliary":[186],"through":[188],"DC-AC":[190],"converter,":[191],"enhancing":[192],"management":[196],"network.":[199,284],"Current":[200],"probes":[201,232],"are":[202,233],"strategically":[203],"monitor":[206],"flow":[209],"between":[210],"regions":[213],"charger,":[217],"providing":[218],"measurements":[220],"delivered":[224],"reclaimed.":[226],"data":[228],"collected":[229],"these":[231],"subsequently":[234],"processed":[235],"Matlab/Simulink":[237],"comprehensive":[240],"analysis.":[241],"approach":[243],"allows":[244],"an":[246],"in-depth":[247],"examination":[248],"energy-transfer":[251],"dynamics,":[252],"recovery,":[256],"potential":[259],"impact":[260],"performance.":[265],"findings":[267],"offer":[268],"valuable":[269],"information":[270],"optimizing":[272],"utilization,":[275],"contributing":[276],"more":[279],"sustainable":[280],"efficient":[282]},"counts_by_year":[],"updated_date":"2026-03-07T16:01:11.037858","created_date":"2025-11-06T00:00:00"}
