{"id":"https://openalex.org/W4415970002","doi":"https://doi.org/10.1109/iecon58223.2025.11221606","title":"Online Reinforcement Learning Approach for Real-Time Energy Management of Grid-Connected Battery Storage Microgrid System","display_name":"Online Reinforcement Learning Approach for Real-Time Energy Management of Grid-Connected Battery Storage Microgrid System","publication_year":2025,"publication_date":"2025-10-14","ids":{"openalex":"https://openalex.org/W4415970002","doi":"https://doi.org/10.1109/iecon58223.2025.11221606"},"language":null,"primary_location":{"id":"doi:10.1109/iecon58223.2025.11221606","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon58223.2025.11221606","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2025 \u2013 51st Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Xiangru Shi","orcid":null},"institutions":[{"id":"https://openalex.org/I37553959","display_name":"Universit\u00e9 de technologie de belfort-montb\u00e9liard","ror":"https://ror.org/05bn3m307","country_code":"FR","type":"education","lineage":["https://openalex.org/I37553959"]}],"countries":["FR"],"is_corresponding":true,"raw_author_name":"Xiangru Shi","raw_affiliation_strings":["FEMTO-ST Institute, UTBM,Department of Energy,Belfort,France"],"affiliations":[{"raw_affiliation_string":"FEMTO-ST Institute, UTBM,Department of Energy,Belfort,France","institution_ids":["https://openalex.org/I37553959"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5089870423","display_name":"Flavie Didier","orcid":"https://orcid.org/0000-0001-5380-5492"},"institutions":[{"id":"https://openalex.org/I37553959","display_name":"Universit\u00e9 de technologie de belfort-montb\u00e9liard","ror":"https://ror.org/05bn3m307","country_code":"FR","type":"education","lineage":["https://openalex.org/I37553959"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Flavie Didier","raw_affiliation_strings":["FEMTO-ST Institute, UTBM,Department of Energy,Belfort,France"],"affiliations":[{"raw_affiliation_string":"FEMTO-ST Institute, UTBM,Department of Energy,Belfort,France","institution_ids":["https://openalex.org/I37553959"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5024606271","display_name":"Abderrezak Badji","orcid":"https://orcid.org/0000-0002-8623-8065"},"institutions":[{"id":"https://openalex.org/I2800745255","display_name":"Universit\u00e9 de Haute-Alsace","ror":"https://ror.org/04k8k6n84","country_code":"FR","type":"education","lineage":["https://openalex.org/I2800745255"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Abderrezak Badji","raw_affiliation_strings":["Universit&#x00E9; de Haute Alsace,IRIMAS,Mulhouse,France"],"affiliations":[{"raw_affiliation_string":"Universit&#x00E9; de Haute Alsace,IRIMAS,Mulhouse,France","institution_ids":["https://openalex.org/I2800745255"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5061002265","display_name":"Sheikh Izzal Azid","orcid":"https://orcid.org/0000-0003-1151-0973"},"institutions":[{"id":"https://openalex.org/I176790772","display_name":"Murdoch University","ror":"https://ror.org/00r4sry34","country_code":"AU","type":"education","lineage":["https://openalex.org/I176790772"]}],"countries":["AU"],"is_corresponding":false,"raw_author_name":"Sheikh Izzal Azid","raw_affiliation_strings":["Murdoch University,School of Engineering and Energy,Perth,Australia"],"affiliations":[{"raw_affiliation_string":"Murdoch University,School of Engineering and Energy,Perth,Australia","institution_ids":["https://openalex.org/I176790772"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5050796012","display_name":"Maurizio Cirrincione","orcid":"https://orcid.org/0000-0003-1886-1514"},"institutions":[{"id":"https://openalex.org/I29894533","display_name":"Charles Darwin University","ror":"https://ror.org/048zcaj52","country_code":"AU","type":"education","lineage":["https://openalex.org/I29894533"]}],"countries":["AU"],"is_corresponding":false,"raw_author_name":"Maurizio Cirrincione","raw_affiliation_strings":["Charles Darwin University,Energy and Resources Institute,Darwin,Australia"],"affiliations":[{"raw_affiliation_string":"Charles Darwin University,Energy and Resources Institute,Darwin,Australia","institution_ids":["https://openalex.org/I29894533"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5022583193","display_name":"Salah Laghrouche","orcid":"https://orcid.org/0000-0002-1913-4848"},"institutions":[{"id":"https://openalex.org/I37553959","display_name":"Universit\u00e9 de technologie de belfort-montb\u00e9liard","ror":"https://ror.org/05bn3m307","country_code":"FR","type":"education","lineage":["https://openalex.org/I37553959"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Salah Laghrouche","raw_affiliation_strings":["FEMTO-ST Institute, UTBM,Department of Energy,Belfort,France"],"affiliations":[{"raw_affiliation_string":"FEMTO-ST Institute, UTBM,Department of Energy,Belfort,France","institution_ids":["https://openalex.org/I37553959"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":6,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I37553959"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.4005529,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"7"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.8773000240325928,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.8773000240325928,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.04659999907016754,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10663","display_name":"Advanced Battery Technologies Research","score":0.04390000179409981,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/reinforcement-learning","display_name":"Reinforcement learning","score":0.8399999737739563},{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.7476999759674072},{"id":"https://openalex.org/keywords/markov-decision-process","display_name":"Markov decision process","score":0.7164999842643738},{"id":"https://openalex.org/keywords/battery","display_name":"Battery (electricity)","score":0.5949000120162964},{"id":"https://openalex.org/keywords/energy-management","display_name":"Energy management","score":0.5372999906539917},{"id":"https://openalex.org/keywords/flexibility","display_name":"Flexibility (engineering)","score":0.5146999955177307},{"id":"https://openalex.org/keywords/scheduling","display_name":"Scheduling (production processes)","score":0.47540000081062317},{"id":"https://openalex.org/keywords/energy-storage","display_name":"Energy storage","score":0.47269999980926514},{"id":"https://openalex.org/keywords/energy-management-system","display_name":"Energy management system","score":0.42579999566078186}],"concepts":[{"id":"https://openalex.org/C97541855","wikidata":"https://www.wikidata.org/wiki/Q830687","display_name":"Reinforcement learning","level":2,"score":0.8399999737739563},{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.7476999759674072},{"id":"https://openalex.org/C106189395","wikidata":"https://www.wikidata.org/wiki/Q176789","display_name":"Markov decision process","level":3,"score":0.7164999842643738},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6060000061988831},{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.5949000120162964},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.5372999906539917},{"id":"https://openalex.org/C2780598303","wikidata":"https://www.wikidata.org/wiki/Q65921492","display_name":"Flexibility (engineering)","level":2,"score":0.5146999955177307},{"id":"https://openalex.org/C206729178","wikidata":"https://www.wikidata.org/wiki/Q2271896","display_name":"Scheduling (production processes)","level":2,"score":0.47540000081062317},{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.47269999980926514},{"id":"https://openalex.org/C2781260460","wikidata":"https://www.wikidata.org/wiki/Q6139999","display_name":"Energy management system","level":4,"score":0.42579999566078186},{"id":"https://openalex.org/C2779370713","wikidata":"https://www.wikidata.org/wiki/Q357554","display_name":"Load management","level":2,"score":0.392300009727478},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3865000009536743},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.3774000108242035},{"id":"https://openalex.org/C159886148","wikidata":"https://www.wikidata.org/wiki/Q176645","display_name":"Markov process","level":2,"score":0.34549999237060547},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.31360000371932983},{"id":"https://openalex.org/C55416958","wikidata":"https://www.wikidata.org/wiki/Q6206757","display_name":"Job shop scheduling","level":3,"score":0.30809998512268066},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.30250000953674316},{"id":"https://openalex.org/C2779438525","wikidata":"https://www.wikidata.org/wiki/Q5255048","display_name":"Demand response","level":3,"score":0.2854999899864197},{"id":"https://openalex.org/C188116033","wikidata":"https://www.wikidata.org/wiki/Q2664563","display_name":"Q-learning","level":3,"score":0.28540000319480896},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.2766000032424927},{"id":"https://openalex.org/C91575142","wikidata":"https://www.wikidata.org/wiki/Q1971426","display_name":"Optimal control","level":2,"score":0.27300000190734863},{"id":"https://openalex.org/C2777908891","wikidata":"https://www.wikidata.org/wiki/Q1806775","display_name":"Load profile","level":3,"score":0.26809999346733093},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.2671000063419342},{"id":"https://openalex.org/C98763669","wikidata":"https://www.wikidata.org/wiki/Q176645","display_name":"Markov chain","level":2,"score":0.26260000467300415},{"id":"https://openalex.org/C112972136","wikidata":"https://www.wikidata.org/wiki/Q7595718","display_name":"Stability (learning theory)","level":2,"score":0.2605000138282776},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.25949999690055847},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.2567000091075897}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon58223.2025.11221606","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon58223.2025.11221606","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2025 \u2013 51st Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":11,"referenced_works":["https://openalex.org/W2011418219","https://openalex.org/W2168359464","https://openalex.org/W2731839291","https://openalex.org/W3006721701","https://openalex.org/W3119250031","https://openalex.org/W3196905284","https://openalex.org/W4280543637","https://openalex.org/W4294343644","https://openalex.org/W4320495830","https://openalex.org/W4378530152","https://openalex.org/W4407715195"],"related_works":[],"abstract_inverted_index":{"Battery":[0],"storage":[1],"systems":[2],"(BSS)":[3],"are":[4],"critical":[5],"for":[6,23,106],"maintaining":[7],"stability":[8],"and":[9,18,55,67,90],"flexibility":[10],"in":[11,40,84,110],"renewable":[12],"energy":[13,25,88,112],"microgrids.":[14],"However,":[15],"the":[16,77],"generation":[17],"load":[19],"profiles":[20],"introduce":[21],"challenges":[22],"optimal":[24,65],"management.":[26],"This":[27,98],"study":[28,99],"presents":[29],"a":[30,41,50,56],"deep":[31],"reinforcement":[32,103],"learning":[33],"(DRL)":[34],"approach":[35],"to":[36,63,94,101],"real-time":[37,107],"battery":[38,91,108],"scheduling":[39,109],"grid-connected":[42],"microgrid.":[43],"The":[44],"control":[45],"problem":[46],"is":[47,61],"modeled":[48],"as":[49],"Markov":[51],"decision":[52],"process":[53],"(MDP),":[54],"Deep":[57],"Q-Network":[58],"(DQN)":[59],"agent":[60],"trained":[62],"output":[64],"charging":[66],"discharging":[68],"actions":[69],"based":[70],"on":[71],"system":[72],"states.":[73],"Results":[74],"indicate":[75],"that":[76],"proposed":[78],"DQN-based":[79],"EMS":[80],"achieves":[81],"superior":[82],"performance":[83],"balancing":[85],"economic":[86],"cost,":[87],"self-sufficiency,":[89],"health":[92],"compared":[93],"conventional":[95],"rule-based":[96],"strategy.":[97],"contributes":[100],"advancing":[102],"learning-based":[104],"approaches":[105],"microgrid":[111],"systems.":[113]},"counts_by_year":[],"updated_date":"2026-04-21T08:09:41.155169","created_date":"2025-11-06T00:00:00"}
