{"id":"https://openalex.org/W4415968715","doi":"https://doi.org/10.1109/iecon58223.2025.11221533","title":"Lifecycle co-optimization of microgrid sizing and operation considering battery degradation and flexible supplementation","display_name":"Lifecycle co-optimization of microgrid sizing and operation considering battery degradation and flexible supplementation","publication_year":2025,"publication_date":"2025-10-14","ids":{"openalex":"https://openalex.org/W4415968715","doi":"https://doi.org/10.1109/iecon58223.2025.11221533"},"language":null,"primary_location":{"id":"doi:10.1109/iecon58223.2025.11221533","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon58223.2025.11221533","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2025 \u2013 51st Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5067142463","display_name":"Qi Chen","orcid":"https://orcid.org/0000-0002-2536-763X"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Qi Chen","raw_affiliation_strings":["Tsinghua University,School of Architecture,Beijing,China"],"affiliations":[{"raw_affiliation_string":"Tsinghua University,School of Architecture,Beijing,China","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101663428","display_name":"Yingying Cheng","orcid":"https://orcid.org/0000-0001-7610-9078"},"institutions":[{"id":"https://openalex.org/I2250955327","display_name":"Huawei Technologies (China)","ror":"https://ror.org/00cmhce21","country_code":"CN","type":"company","lineage":["https://openalex.org/I2250955327"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yingying Cheng","raw_affiliation_strings":["Huawei Technologies Co., Ltd,Theory Lab, 2012 Labs,Beijing,China"],"affiliations":[{"raw_affiliation_string":"Huawei Technologies Co., Ltd,Theory Lab, 2012 Labs,Beijing,China","institution_ids":["https://openalex.org/I2250955327"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100403486","display_name":"Fan Zhang","orcid":"https://orcid.org/0000-0002-6257-8911"},"institutions":[{"id":"https://openalex.org/I2250955327","display_name":"Huawei Technologies (China)","ror":"https://ror.org/00cmhce21","country_code":"CN","type":"company","lineage":["https://openalex.org/I2250955327"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Fan Zhang","raw_affiliation_strings":["Huawei Technologies Co., Ltd,Theory Lab, 2012 Labs,Hong Kong,China"],"affiliations":[{"raw_affiliation_string":"Huawei Technologies Co., Ltd,Theory Lab, 2012 Labs,Hong Kong,China","institution_ids":["https://openalex.org/I2250955327"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5110484941","display_name":"J. Zhang","orcid":"https://orcid.org/0000-0003-2177-7284"},"institutions":[{"id":"https://openalex.org/I2250955327","display_name":"Huawei Technologies (China)","ror":"https://ror.org/00cmhce21","country_code":"CN","type":"company","lineage":["https://openalex.org/I2250955327"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jiyuan Zhang","raw_affiliation_strings":["Huawei Technologies Co., Ltd,Digital Energy BU,Shanghai,China"],"affiliations":[{"raw_affiliation_string":"Huawei Technologies Co., Ltd,Digital Energy BU,Shanghai,China","institution_ids":["https://openalex.org/I2250955327"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5007944987","display_name":"Miao Jiang","orcid":"https://orcid.org/0000-0002-7963-6022"},"institutions":[{"id":"https://openalex.org/I2250955327","display_name":"Huawei Technologies (China)","ror":"https://ror.org/00cmhce21","country_code":"CN","type":"company","lineage":["https://openalex.org/I2250955327"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Miao Jiang","raw_affiliation_strings":["Huawei Technologies Co., Ltd,Digital Energy BU,Shanghai,China"],"affiliations":[{"raw_affiliation_string":"Huawei Technologies Co., Ltd,Digital Energy BU,Shanghai,China","institution_ids":["https://openalex.org/I2250955327"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5079534532","display_name":"Yanbai Shen","orcid":"https://orcid.org/0000-0002-9855-3644"},"institutions":[{"id":"https://openalex.org/I2250955327","display_name":"Huawei Technologies (China)","ror":"https://ror.org/00cmhce21","country_code":"CN","type":"company","lineage":["https://openalex.org/I2250955327"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yanbai Shen","raw_affiliation_strings":["Huawei Technologies Co., Ltd,Digital Energy BU,Shanghai,China"],"affiliations":[{"raw_affiliation_string":"Huawei Technologies Co., Ltd,Digital Energy BU,Shanghai,China","institution_ids":["https://openalex.org/I2250955327"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":6,"corresponding_author_ids":["https://openalex.org/A5067142463"],"corresponding_institution_ids":["https://openalex.org/I99065089"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.37971305,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11007","display_name":"Hybrid Renewable Energy Systems","score":0.8815000057220459,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11007","display_name":"Hybrid Renewable Energy Systems","score":0.8815000057220459,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10663","display_name":"Advanced Battery Technologies Research","score":0.05889999866485596,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.025200000032782555,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.7554000020027161},{"id":"https://openalex.org/keywords/battery","display_name":"Battery (electricity)","score":0.7019000053405762},{"id":"https://openalex.org/keywords/sizing","display_name":"Sizing","score":0.6753000020980835},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.5769000053405762},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.5622000098228455},{"id":"https://openalex.org/keywords/heuristic","display_name":"Heuristic","score":0.49900001287460327},{"id":"https://openalex.org/keywords/photovoltaic-system","display_name":"Photovoltaic system","score":0.46050000190734863},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.3968999981880188},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.36489999294281006}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.7554000020027161},{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.7019000053405762},{"id":"https://openalex.org/C2777767291","wikidata":"https://www.wikidata.org/wiki/Q1080291","display_name":"Sizing","level":2,"score":0.6753000020980835},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.6662999987602234},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.5769000053405762},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5699999928474426},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.5622000098228455},{"id":"https://openalex.org/C173801870","wikidata":"https://www.wikidata.org/wiki/Q201413","display_name":"Heuristic","level":2,"score":0.49900001287460327},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.46050000190734863},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.4562999904155731},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3968999981880188},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.36489999294281006},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3596999943256378},{"id":"https://openalex.org/C2779679103","wikidata":"https://www.wikidata.org/wiki/Q5251805","display_name":"Degradation (telecommunications)","level":2,"score":0.358599990606308},{"id":"https://openalex.org/C137836250","wikidata":"https://www.wikidata.org/wiki/Q984063","display_name":"Optimization problem","level":2,"score":0.3546999990940094},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3522999882698059},{"id":"https://openalex.org/C111030470","wikidata":"https://www.wikidata.org/wiki/Q1430460","display_name":"Curse of dimensionality","level":2,"score":0.35010001063346863},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.3197999894618988},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.31850001215934753},{"id":"https://openalex.org/C50897621","wikidata":"https://www.wikidata.org/wiki/Q2665508","display_name":"Hybrid system","level":2,"score":0.3091999888420105},{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.3073999881744385},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.30730000138282776},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.27880001068115234},{"id":"https://openalex.org/C2780106510","wikidata":"https://www.wikidata.org/wiki/Q4822597","display_name":"Depth of discharge","level":4,"score":0.27810001373291016},{"id":"https://openalex.org/C182365436","wikidata":"https://www.wikidata.org/wiki/Q50701","display_name":"Variable (mathematics)","level":2,"score":0.2680000066757202},{"id":"https://openalex.org/C12725497","wikidata":"https://www.wikidata.org/wiki/Q810247","display_name":"Baseline (sea)","level":2,"score":0.2621999979019165},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.26010000705718994}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon58223.2025.11221533","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon58223.2025.11221533","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2025 \u2013 51st Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":11,"referenced_works":["https://openalex.org/W2971305022","https://openalex.org/W3042713179","https://openalex.org/W4220777713","https://openalex.org/W4285725515","https://openalex.org/W4384436086","https://openalex.org/W4387163154","https://openalex.org/W4388285396","https://openalex.org/W4392053659","https://openalex.org/W4399850133","https://openalex.org/W4403670072","https://openalex.org/W4408281021"],"related_works":[],"abstract_inverted_index":{"With":[0],"the":[1,81,92,133,156,160,172,175],"increasing":[2,168],"integration":[3],"of":[4,13,48,141,159,177],"renewable":[5,192],"energy":[6,15,186],"into":[7],"power":[8],"systems,":[9],"effective":[10],"long-term":[11],"planning":[12,31,87],"hybrid":[14,34],"resources\u2014particularly":[16],"those":[17],"involving":[18],"storage\u2014is":[19],"becoming":[20],"essential":[21],"to":[22,62,124],"ensure":[23],"reliability":[24],"and":[25,42,52,69,89,103,121,145,184],"cost-efficiency.":[26],"This":[27],"paper":[28],"presents":[29],"a":[30],"framework":[32,93],"for":[33,74,181],"systems":[35],"that":[36,127],"incorporate":[37],"wind,":[38],"solar,":[39],"diesel":[40],"generation,":[41],"battery":[43,49,65,98,130],"storage,":[44],"with":[45,194],"explicit":[46],"consideration":[47],"state-of-health":[50],"degradation":[51,75,150],"automated":[53],"supplementation":[54],"strategies.":[55],"A":[56],"lifecycle":[57],"optimization":[58,110,180],"model":[59,135,162],"is":[60,154],"developed":[61],"jointly":[63],"determine":[64],"installation":[66],"timing,":[67],"sizing,":[68],"technology":[70],"selection,":[71],"while":[72],"accounting":[73],"dynamics":[76],"over":[77],"time.":[78],"To":[79],"manage":[80],"high":[82],"dimensionality":[83],"introduced":[84],"by":[85,143],"long":[86],"horizons":[88],"hourly":[90],"resolution,":[91],"employs":[94],"techniques":[95],"such":[96],"as":[97],"variable":[99],"aggregation,":[100],"bounds":[101],"tightening,":[102],"hyperparameter":[104],"optimization.":[105],"These":[106],"methods":[107],"enable":[108],"full-system":[109],"within":[111],"1,000\u20132,000":[112],"seconds.":[113],"The":[114],"study":[115],"examines":[116],"two":[117],"system":[118,187],"configurations:":[119],"wind-solar-battery":[120],"wind-solar-diesel-battery.":[122],"Compared":[123],"baseline":[125],"models":[126],"use":[128],"heuristic":[129],"replacement":[131],"strategies,":[132],"proposed":[134,161],"achieves":[136],"reductions":[137],"in":[138,190],"Levelized":[139],"Cost":[140],"Energy":[142],"5.1%":[144],"4.3%,":[146],"respectively.":[147],"When":[148],"photovoltaic":[149],"(0.1%\u20130.2%":[151],"per":[152],"year)":[153],"incorporated,":[155],"cost-saving":[157],"benefits":[158],"become":[163],"even":[164],"more":[165],"significant,":[166],"without":[167],"computational":[169],"complexity.":[170],"Overall,":[171],"results":[173],"underscore":[174],"importance":[176],"degradation-aware,":[178],"full-horizon":[179],"achieving":[182],"cost-effective":[183],"realistic":[185],"planning,":[188],"especially":[189],"large-scale":[191],"deployments":[193],"integrated":[195],"storage.":[196]},"counts_by_year":[],"updated_date":"2026-03-07T16:01:11.037858","created_date":"2025-11-06T00:00:00"}
