{"id":"https://openalex.org/W4415969047","doi":"https://doi.org/10.1109/iecon58223.2025.11221532","title":"Modular DC/DC Converters for Fuel Cell Multi-Stack Systems in Heavy-Duty Applications","display_name":"Modular DC/DC Converters for Fuel Cell Multi-Stack Systems in Heavy-Duty Applications","publication_year":2025,"publication_date":"2025-10-14","ids":{"openalex":"https://openalex.org/W4415969047","doi":"https://doi.org/10.1109/iecon58223.2025.11221532"},"language":null,"primary_location":{"id":"doi:10.1109/iecon58223.2025.11221532","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon58223.2025.11221532","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2025 \u2013 51st Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5115798718","display_name":"Ines Siad","orcid":null},"institutions":[{"id":"https://openalex.org/I265217849","display_name":"IFP \u00c9nergies nouvelles","ror":"https://ror.org/03gcbhc33","country_code":"FR","type":"facility","lineage":["https://openalex.org/I265217849"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Ines Siad","raw_affiliation_strings":["Institut Carnot IFPEN Transports Energie,IFP Energies Nouvelles,France,92852"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institut Carnot IFPEN Transports Energie,IFP Energies Nouvelles,France,92852","institution_ids":["https://openalex.org/I265217849"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5069817052","display_name":"Alexandre Battiston","orcid":"https://orcid.org/0000-0001-9566-5563"},"institutions":[{"id":"https://openalex.org/I265217849","display_name":"IFP \u00c9nergies nouvelles","ror":"https://ror.org/03gcbhc33","country_code":"FR","type":"facility","lineage":["https://openalex.org/I265217849"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Alexandre Battiston","raw_affiliation_strings":["Institut Carnot IFPEN Transports Energie,IFP Energies Nouvelles,France,92852"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institut Carnot IFPEN Transports Energie,IFP Energies Nouvelles,France,92852","institution_ids":["https://openalex.org/I265217849"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5025341744","display_name":"Thomas Leroy","orcid":"https://orcid.org/0000-0001-7327-9258"},"institutions":[{"id":"https://openalex.org/I265217849","display_name":"IFP \u00c9nergies nouvelles","ror":"https://ror.org/03gcbhc33","country_code":"FR","type":"facility","lineage":["https://openalex.org/I265217849"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Thomas Leroy","raw_affiliation_strings":["Institut Carnot IFPEN Transports Energie,IFP Energies Nouvelles,France,92852"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institut Carnot IFPEN Transports Energie,IFP Energies Nouvelles,France,92852","institution_ids":["https://openalex.org/I265217849"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5067132528","display_name":"Serge Pierfederici","orcid":"https://orcid.org/0000-0003-3682-6317"},"institutions":[{"id":"https://openalex.org/I1294671590","display_name":"Centre National de la Recherche Scientifique","ror":"https://ror.org/02feahw73","country_code":"FR","type":"government","lineage":["https://openalex.org/I1294671590"]},{"id":"https://openalex.org/I4210110956","display_name":"Laboratoire \u00c9nergies et M\u00e9canique Th\u00e9orique et Appliqu\u00e9e","ror":"https://ror.org/01pfter31","country_code":"FR","type":"facility","lineage":["https://openalex.org/I1294671590","https://openalex.org/I1294671590","https://openalex.org/I4210095849","https://openalex.org/I4210110956","https://openalex.org/I90183372"]},{"id":"https://openalex.org/I90183372","display_name":"Universit\u00e9 de Lorraine","ror":"https://ror.org/04vfs2w97","country_code":"FR","type":"education","lineage":["https://openalex.org/I90183372"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Serge Pierfederici","raw_affiliation_strings":["Universit&#x00E9; de Lorraine,LEMTA, CNRS,Vand&#x0153;uvre-l&#x00E8;s-Nancy,France,54500"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universit&#x00E9; de Lorraine,LEMTA, CNRS,Vand&#x0153;uvre-l&#x00E8;s-Nancy,France,54500","institution_ids":["https://openalex.org/I90183372","https://openalex.org/I1294671590","https://openalex.org/I4210110956"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.27165766,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10409","display_name":"Fuel Cells and Related Materials","score":0.2700999975204468,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10409","display_name":"Fuel Cells and Related Materials","score":0.2700999975204468,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.20360000431537628,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10808","display_name":"Electric and Hybrid Vehicle Technologies","score":0.17190000414848328,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/modular-design","display_name":"Modular design","score":0.7106000185012817},{"id":"https://openalex.org/keywords/modularity","display_name":"Modularity (biology)","score":0.6534000039100647},{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.6449999809265137},{"id":"https://openalex.org/keywords/control-reconfiguration","display_name":"Control reconfiguration","score":0.6269000172615051},{"id":"https://openalex.org/keywords/scalability","display_name":"Scalability","score":0.5848000049591064},{"id":"https://openalex.org/keywords/fuel-cells","display_name":"Fuel cells","score":0.4814000129699707},{"id":"https://openalex.org/keywords/key","display_name":"Key (lock)","score":0.39320001006126404},{"id":"https://openalex.org/keywords/power-electronics","display_name":"Power electronics","score":0.38749998807907104},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.38440001010894775}],"concepts":[{"id":"https://openalex.org/C101468663","wikidata":"https://www.wikidata.org/wiki/Q1620158","display_name":"Modular design","level":2,"score":0.7106000185012817},{"id":"https://openalex.org/C2779478453","wikidata":"https://www.wikidata.org/wiki/Q6889748","display_name":"Modularity (biology)","level":2,"score":0.6534000039100647},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.6449999809265137},{"id":"https://openalex.org/C119701452","wikidata":"https://www.wikidata.org/wiki/Q5165881","display_name":"Control reconfiguration","level":2,"score":0.6269000172615051},{"id":"https://openalex.org/C48044578","wikidata":"https://www.wikidata.org/wiki/Q727490","display_name":"Scalability","level":2,"score":0.5848000049591064},{"id":"https://openalex.org/C2987658370","wikidata":"https://www.wikidata.org/wiki/Q180253","display_name":"Fuel cells","level":2,"score":0.4814000129699707},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.47620001435279846},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4246000051498413},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.39320001006126404},{"id":"https://openalex.org/C178911571","wikidata":"https://www.wikidata.org/wiki/Q593143","display_name":"Power electronics","level":3,"score":0.38749998807907104},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.38440001010894775},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3774000108242035},{"id":"https://openalex.org/C68189081","wikidata":"https://www.wikidata.org/wiki/Q12748","display_name":"Fossil fuel","level":2,"score":0.31850001215934753},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.31189998984336853},{"id":"https://openalex.org/C138331895","wikidata":"https://www.wikidata.org/wiki/Q11650","display_name":"Electronics","level":2,"score":0.3003999888896942},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.2948000133037567},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.2935999929904938},{"id":"https://openalex.org/C2780598303","wikidata":"https://www.wikidata.org/wiki/Q65921492","display_name":"Flexibility (engineering)","level":2,"score":0.27970001101493835},{"id":"https://openalex.org/C201995342","wikidata":"https://www.wikidata.org/wiki/Q682496","display_name":"Systems engineering","level":1,"score":0.27810001373291016},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.2754000127315521},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.27250000834465027},{"id":"https://openalex.org/C423512","wikidata":"https://www.wikidata.org/wiki/Q383973","display_name":"Electricity generation","level":3,"score":0.2700999975204468},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.2685000002384186},{"id":"https://openalex.org/C2776190866","wikidata":"https://www.wikidata.org/wiki/Q1341477","display_name":"Energy supply","level":3,"score":0.26809999346733093},{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.26440000534057617},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.2614000141620636},{"id":"https://openalex.org/C40293303","wikidata":"https://www.wikidata.org/wiki/Q27137","display_name":"Electric power","level":3,"score":0.25859999656677246},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.25099998712539673},{"id":"https://openalex.org/C84462506","wikidata":"https://www.wikidata.org/wiki/Q173142","display_name":"Digital signal processing","level":2,"score":0.25029999017715454}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon58223.2025.11221532","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon58223.2025.11221532","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2025 \u2013 51st Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G5348275422","display_name":"Optimization of HYbrid energy SyStem with multi-stack PEM fuel cells for heavy duty transportation applications","funder_award_id":"ANR-22-PEHY-0018","funder_id":"https://openalex.org/F4320320883","funder_display_name":"Agence Nationale de la Recherche"}],"funders":[{"id":"https://openalex.org/F4320320883","display_name":"Agence Nationale de la Recherche","ror":"https://ror.org/00rbzpz17"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":8,"referenced_works":["https://openalex.org/W1989327071","https://openalex.org/W2031423679","https://openalex.org/W2064340576","https://openalex.org/W2203095370","https://openalex.org/W2595160156","https://openalex.org/W3095660295","https://openalex.org/W4210799239","https://openalex.org/W4317620462"],"related_works":[],"abstract_inverted_index":{"The":[0,71],"growing":[1],"need":[2],"to":[3,15,52,77],"decarbonize":[4],"the":[5,10,54,58,110,114],"transport":[6],"sector":[7],"has":[8],"accelerated":[9],"development":[11],"of":[12,39,63,113],"sustainable":[13],"alternatives":[14],"fossil":[16],"fuels":[17],"such":[18,85],"as":[19,53,86],"hydrogen-powered":[20],"electric":[21],"vehicles.":[22],"In":[23],"this":[24],"context,":[25],"power":[26,36,87],"electronics":[27],"converters":[28],"are":[29,100,124],"essential":[30],"for":[31],"efficient":[32],"energy":[33],"transfer":[34],"and":[35,60,94,105,120],"flow":[37],"management":[38],"Fuel":[40,65],"Cell":[41,66],"systems.":[42],"This":[43],"paper":[44],"presents":[45],"an":[46],"innovative":[47],"DC/DC":[48],"converter":[49,73],"architecture,":[50],"referred":[51],"\"Parallel-Cascade\",":[55],"that":[56],"addresses":[57],"modularity":[59],"scalability":[61],"demands":[62],"Multi-Stack":[64,79],"systems":[67],"in":[68],"Heavy-Duty":[69],"applications.":[70],"proposed":[72,115],"architecture":[74],"is":[75],"compared":[76],"conventional":[78],"configurations,":[80],"using":[81],"key":[82],"performance":[83],"indicators":[84],"losses,":[88],"components":[89],"stress":[90],"factors,":[91],"stored":[92],"energy,":[93],"relevant":[95],"qualitative":[96],"criteria.":[97],"Simulation":[98],"results":[99],"provided":[101],"under":[102],"both":[103],"normal":[104],"faulty":[106],"operating":[107],"conditions,":[108],"highlighting":[109],"reconfiguration":[111],"capability":[112],"control":[116],"scheme.":[117],"Prototype":[118],"design":[119],"preliminary":[121],"experimental":[122],"validation":[123],"also":[125],"presented.":[126]},"counts_by_year":[],"updated_date":"2025-11-07T23:20:04.922697","created_date":"2025-11-06T00:00:00"}
