{"id":"https://openalex.org/W4415968717","doi":"https://doi.org/10.1109/iecon58223.2025.11221381","title":"A Devlopment of Cascade Cooling System Using Two Vapor Compression Refrigeration Systems for Thermal Energy Management of Electric Vehicle","display_name":"A Devlopment of Cascade Cooling System Using Two Vapor Compression Refrigeration Systems for Thermal Energy Management of Electric Vehicle","publication_year":2025,"publication_date":"2025-10-14","ids":{"openalex":"https://openalex.org/W4415968717","doi":"https://doi.org/10.1109/iecon58223.2025.11221381"},"language":null,"primary_location":{"id":"doi:10.1109/iecon58223.2025.11221381","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon58223.2025.11221381","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2025 \u2013 51st Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"JaeHyun Song","orcid":null},"institutions":[{"id":"https://openalex.org/I49946491","display_name":"Hyundai Motors (South Korea)","ror":"https://ror.org/016kvft77","country_code":"KR","type":"company","lineage":["https://openalex.org/I197312522","https://openalex.org/I49946491"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"JaeHyun Song","raw_affiliation_strings":["Hyundai Motor Company,Thermal Energy Test Team2,Hwaseong-Si,Korea,150"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Hyundai Motor Company,Thermal Energy Test Team2,Hwaseong-Si,Korea,150","institution_ids":["https://openalex.org/I49946491"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101747209","display_name":"Tae-Han Kim","orcid":"https://orcid.org/0000-0002-6963-6483"},"institutions":[{"id":"https://openalex.org/I49946491","display_name":"Hyundai Motors (South Korea)","ror":"https://ror.org/016kvft77","country_code":"KR","type":"company","lineage":["https://openalex.org/I197312522","https://openalex.org/I49946491"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Taehan Kim","raw_affiliation_strings":["Hyundai Motor Company,Thermal Energy Test Team2,Hwaseong-Si,Korea,150"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Hyundai Motor Company,Thermal Energy Test Team2,Hwaseong-Si,Korea,150","institution_ids":["https://openalex.org/I49946491"]}]},{"author_position":"middle","author":{"id":null,"display_name":"HwanYeui Hong","orcid":null},"institutions":[{"id":"https://openalex.org/I49946491","display_name":"Hyundai Motors (South Korea)","ror":"https://ror.org/016kvft77","country_code":"KR","type":"company","lineage":["https://openalex.org/I197312522","https://openalex.org/I49946491"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"HwanYeui Hong","raw_affiliation_strings":["Hyundai Motor Company,Thermal Energy Test Team2,Hwaseong-Si,Korea,150"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Hyundai Motor Company,Thermal Energy Test Team2,Hwaseong-Si,Korea,150","institution_ids":["https://openalex.org/I49946491"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101753987","display_name":"Sung-Hyun Moon","orcid":"https://orcid.org/0000-0002-6757-379X"},"institutions":[{"id":"https://openalex.org/I49946491","display_name":"Hyundai Motors (South Korea)","ror":"https://ror.org/016kvft77","country_code":"KR","type":"company","lineage":["https://openalex.org/I197312522","https://openalex.org/I49946491"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"SungHyun Moon","raw_affiliation_strings":["Hyundai Motor Company,Thermal Energy Test Team2,Hwaseong-Si,Korea,150"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Hyundai Motor Company,Thermal Energy Test Team2,Hwaseong-Si,Korea,150","institution_ids":["https://openalex.org/I49946491"]}]},{"author_position":"last","author":{"id":null,"display_name":"Chul-Min Kim","orcid":null},"institutions":[{"id":"https://openalex.org/I4210166862","display_name":"Advanced Engineering (Czechia)","ror":"https://ror.org/05w67p097","country_code":"CZ","type":"company","lineage":["https://openalex.org/I4210166862"]}],"countries":["CZ"],"is_corresponding":false,"raw_author_name":"Chul-Min Kim","raw_affiliation_strings":["Doowon Climate Control Co., Ltd.,Advanced Research Department,Asan-si,43"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Doowon Climate Control Co., Ltd.,Advanced Research Department,Asan-si,43","institution_ids":["https://openalex.org/I4210166862"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.29100072,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.7634999752044678,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.7634999752044678,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14250","display_name":"Energy and Environmental Systems","score":0.036400001496076584,"subfield":{"id":"https://openalex.org/subfields/3313","display_name":"Transportation"},"field":{"id":"https://openalex.org/fields/33","display_name":"Social Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}},{"id":"https://openalex.org/T12081","display_name":"Aerodynamics and Fluid Dynamics Research","score":0.03400000184774399,"subfield":{"id":"https://openalex.org/subfields/2202","display_name":"Aerospace Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/vapor-compression-refrigeration","display_name":"Vapor-compression refrigeration","score":0.7939000129699707},{"id":"https://openalex.org/keywords/refrigeration","display_name":"Refrigeration","score":0.7064999938011169},{"id":"https://openalex.org/keywords/cascade","display_name":"Cascade","score":0.6417999863624573},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"Air conditioning","score":0.6392999887466431},{"id":"https://openalex.org/keywords/battery","display_name":"Battery (electricity)","score":0.6050999760627747},{"id":"https://openalex.org/keywords/water-cooling","display_name":"Water cooling","score":0.5805000066757202},{"id":"https://openalex.org/keywords/electric-vehicle-battery","display_name":"Electric-vehicle battery","score":0.5335999727249146},{"id":"https://openalex.org/keywords/cooling-load","display_name":"Cooling load","score":0.5314000248908997}],"concepts":[{"id":"https://openalex.org/C36570524","wikidata":"https://www.wikidata.org/wiki/Q615475","display_name":"Vapor-compression refrigeration","level":4,"score":0.7939000129699707},{"id":"https://openalex.org/C69907114","wikidata":"https://www.wikidata.org/wiki/Q747713","display_name":"Refrigeration","level":2,"score":0.7064999938011169},{"id":"https://openalex.org/C34146451","wikidata":"https://www.wikidata.org/wiki/Q5048094","display_name":"Cascade","level":2,"score":0.6417999863624573},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.6392999887466431},{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.6050999760627747},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.6000000238418579},{"id":"https://openalex.org/C7694927","wikidata":"https://www.wikidata.org/wiki/Q7667810","display_name":"Water cooling","level":2,"score":0.5805000066757202},{"id":"https://openalex.org/C2779136927","wikidata":"https://www.wikidata.org/wiki/Q900762","display_name":"Electric-vehicle battery","level":4,"score":0.5335999727249146},{"id":"https://openalex.org/C2781099182","wikidata":"https://www.wikidata.org/wiki/Q24963825","display_name":"Cooling load","level":3,"score":0.5314000248908997},{"id":"https://openalex.org/C2776422217","wikidata":"https://www.wikidata.org/wiki/Q13629441","display_name":"Electric vehicle","level":3,"score":0.5059000253677368},{"id":"https://openalex.org/C105873366","wikidata":"https://www.wikidata.org/wiki/Q1208873","display_name":"Air cooling","level":2,"score":0.47760000824928284},{"id":"https://openalex.org/C164915370","wikidata":"https://www.wikidata.org/wiki/Q5167494","display_name":"Cooling capacity","level":2,"score":0.42260000109672546},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.39480000734329224},{"id":"https://openalex.org/C156820238","wikidata":"https://www.wikidata.org/wiki/Q422876","display_name":"Active cooling","level":3,"score":0.3790999948978424},{"id":"https://openalex.org/C2778508592","wikidata":"https://www.wikidata.org/wiki/Q420116","display_name":"Battery pack","level":4,"score":0.34950000047683716},{"id":"https://openalex.org/C199499590","wikidata":"https://www.wikidata.org/wiki/Q266790","display_name":"Refrigerant","level":3,"score":0.3206000030040741},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.3183000087738037},{"id":"https://openalex.org/C116915560","wikidata":"https://www.wikidata.org/wiki/Q83504","display_name":"Nuclear engineering","level":1,"score":0.31459999084472656},{"id":"https://openalex.org/C180016635","wikidata":"https://www.wikidata.org/wiki/Q2712821","display_name":"Compression (physics)","level":2,"score":0.3125},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.30219998955726624},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.2978000044822693},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.2922999858856201},{"id":"https://openalex.org/C2983288566","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Central air conditioning","level":3,"score":0.2791999876499176},{"id":"https://openalex.org/C173991790","wikidata":"https://www.wikidata.org/wiki/Q1896787","display_name":"Evaporative cooler","level":2,"score":0.258899986743927},{"id":"https://openalex.org/C13119800","wikidata":"https://www.wikidata.org/wiki/Q902090","display_name":"Coefficient of performance","level":4,"score":0.2522999942302704}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon58223.2025.11221381","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon58223.2025.11221381","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2025 \u2013 51st Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320310381","display_name":"Hyundai Motor Group","ror":"https://ror.org/05kxbz959"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W2805508446","https://openalex.org/W4304188355","https://openalex.org/W4322505063","https://openalex.org/W4389818766"],"related_works":[],"abstract_inverted_index":{"The":[0],"next-generation":[1],"electric":[2],"vehicle":[3,39],"will":[4],"be":[5],"applied":[6],"with":[7,34],"a":[8,35,67],"next":[9],"generation":[10],"battery":[11,54,113],"and":[12,53,93],"autonomous":[13],"driving":[14],"system":[15,46,70,92,96],"that":[16,107],"generates":[17],"high":[18],"heat.":[19],"However,":[20,42],"since":[21],"the":[22,43,57,81,85,90,94,101,108,112,117,121,126],"proper":[23],"operating":[24],"temperature":[25],"is":[26,29,47],"low,":[27],"it":[28,33,104],"essential":[30],"to":[31,49,61,100],"combine":[32],"refrigeration":[36,75],"cycle":[37],"for":[38,80],"air":[40,51,122],"conditioning.":[41],"existing":[44,91,102],"cooling":[45,69,109,118],"difficult":[48],"satisfy":[50],"conditioning":[52,123],"load":[55],"at":[56,125],"same":[58,127],"time,":[59],"so":[60],"solve":[62],"this":[63,88],"problem,":[64],"we":[65],"developed":[66],"cascade":[68,95],"using":[71],"two":[72],"vapor":[73],"compression":[74],"systems":[76],"connected":[77],"by":[78],"PIHX":[79],"first":[82],"time":[83],"in":[84],"world.":[86],"In":[87],"paper,":[89],"were":[97],"compared.":[98],"Compared":[99],"system,":[103],"was":[105,114,124],"found":[106],"performance":[110,119],"of":[111,120],"improved":[115],"while":[116],"level.":[128]},"counts_by_year":[],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-11-06T00:00:00"}
