{"id":"https://openalex.org/W4415969016","doi":"https://doi.org/10.1109/iecon58223.2025.11221158","title":"Design of an Integrated Fault Limiting and Isolating DCPFC for HVDC Mesh Grids","display_name":"Design of an Integrated Fault Limiting and Isolating DCPFC for HVDC Mesh Grids","publication_year":2025,"publication_date":"2025-10-14","ids":{"openalex":"https://openalex.org/W4415969016","doi":"https://doi.org/10.1109/iecon58223.2025.11221158"},"language":null,"primary_location":{"id":"doi:10.1109/iecon58223.2025.11221158","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon58223.2025.11221158","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2025 \u2013 51st Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5040115705","display_name":"Yu Gao","orcid":"https://orcid.org/0009-0008-2830-8150"},"institutions":[{"id":"https://openalex.org/I204983213","display_name":"Harbin Institute of Technology","ror":"https://ror.org/01yqg2h08","country_code":"CN","type":"education","lineage":["https://openalex.org/I204983213"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yu Gao","raw_affiliation_strings":["Harbin Institute of Technology, Shenzhen,Department of Electrical Engineering,Shenzhen,China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Harbin Institute of Technology, Shenzhen,Department of Electrical Engineering,Shenzhen,China","institution_ids":["https://openalex.org/I204983213"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5073071581","display_name":"Xuan Wang","orcid":"https://orcid.org/0000-0003-0639-2044"},"institutions":[{"id":"https://openalex.org/I204983213","display_name":"Harbin Institute of Technology","ror":"https://ror.org/01yqg2h08","country_code":"CN","type":"education","lineage":["https://openalex.org/I204983213"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xuan Wang","raw_affiliation_strings":["Harbin Institute of Technology, Shenzhen,Department of Electrical Engineering,Shenzhen,China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Harbin Institute of Technology, Shenzhen,Department of Electrical Engineering,Shenzhen,China","institution_ids":["https://openalex.org/I204983213"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100428578","display_name":"Can Wang","orcid":"https://orcid.org/0000-0002-4596-4298"},"institutions":[{"id":"https://openalex.org/I204983213","display_name":"Harbin Institute of Technology","ror":"https://ror.org/01yqg2h08","country_code":"CN","type":"education","lineage":["https://openalex.org/I204983213"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Can Wang","raw_affiliation_strings":["Harbin Institute of Technology, Shenzhen,Department of Electrical Engineering,Shenzhen,China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Harbin Institute of Technology, Shenzhen,Department of Electrical Engineering,Shenzhen,China","institution_ids":["https://openalex.org/I204983213"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I204983213"],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"7"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9952999949455261,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9952999949455261,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.002199999988079071,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.0003000000142492354,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.595300018787384},{"id":"https://openalex.org/keywords/fault-current-limiter","display_name":"Fault current limiter","score":0.5537999868392944},{"id":"https://openalex.org/keywords/circuit-breaker","display_name":"Circuit breaker","score":0.5063999891281128},{"id":"https://openalex.org/keywords/capacitor","display_name":"Capacitor","score":0.4767000079154968},{"id":"https://openalex.org/keywords/thyristor","display_name":"Thyristor","score":0.46720001101493835},{"id":"https://openalex.org/keywords/electric-power-transmission","display_name":"Electric power transmission","score":0.42640000581741333},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.41679999232292175},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.41350001096725464},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.39089998602867126},{"id":"https://openalex.org/keywords/maximum-power-transfer-theorem","display_name":"Maximum power transfer theorem","score":0.39010000228881836}],"concepts":[{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.595300018787384},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5672000050544739},{"id":"https://openalex.org/C129187525","wikidata":"https://www.wikidata.org/wiki/Q10858078","display_name":"Fault current limiter","level":4,"score":0.5537999868392944},{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.5063999891281128},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.4767000079154968},{"id":"https://openalex.org/C121922863","wikidata":"https://www.wikidata.org/wiki/Q180805","display_name":"Thyristor","level":3,"score":0.46720001101493835},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.42640000581741333},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.41679999232292175},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.41350001096725464},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4131999909877777},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.40709999203681946},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.39089998602867126},{"id":"https://openalex.org/C67186554","wikidata":"https://www.wikidata.org/wiki/Q17103352","display_name":"Maximum power transfer theorem","level":3,"score":0.39010000228881836},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.3855000138282776},{"id":"https://openalex.org/C38361682","wikidata":"https://www.wikidata.org/wiki/Q1756067","display_name":"Power-system protection","level":4,"score":0.38449999690055847},{"id":"https://openalex.org/C92018576","wikidata":"https://www.wikidata.org/wiki/Q3242194","display_name":"Power transmission","level":3,"score":0.37529999017715454},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.3650999963283539},{"id":"https://openalex.org/C21267803","wikidata":"https://www.wikidata.org/wiki/Q5438159","display_name":"Fault indicator","level":4,"score":0.35989999771118164},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.35749998688697815},{"id":"https://openalex.org/C199845137","wikidata":"https://www.wikidata.org/wiki/Q145490","display_name":"Network topology","level":2,"score":0.3467999994754791},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.3337000012397766},{"id":"https://openalex.org/C47949032","wikidata":"https://www.wikidata.org/wiki/Q663542","display_name":"Overcurrent","level":3,"score":0.3312999904155731},{"id":"https://openalex.org/C2776352172","wikidata":"https://www.wikidata.org/wiki/Q2494266","display_name":"Unified power flow controller","level":5,"score":0.3215000033378601},{"id":"https://openalex.org/C168993435","wikidata":"https://www.wikidata.org/wiki/Q6501125","display_name":"Ground","level":2,"score":0.3165999948978424},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.2937999963760376},{"id":"https://openalex.org/C15703209","wikidata":"https://www.wikidata.org/wiki/Q333883","display_name":"Overvoltage","level":3,"score":0.29010000824928284},{"id":"https://openalex.org/C2781163877","wikidata":"https://www.wikidata.org/wiki/Q370607","display_name":"High-voltage direct current","level":4,"score":0.28130000829696655},{"id":"https://openalex.org/C113608303","wikidata":"https://www.wikidata.org/wiki/Q1056835","display_name":"Transmission system","level":3,"score":0.27570000290870667},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.27300000190734863},{"id":"https://openalex.org/C204106720","wikidata":"https://www.wikidata.org/wiki/Q15856134","display_name":"Current limiting","level":3,"score":0.26669999957084656},{"id":"https://openalex.org/C63540848","wikidata":"https://www.wikidata.org/wiki/Q3140932","display_name":"Fault tolerance","level":2,"score":0.26339998841285706},{"id":"https://openalex.org/C119701452","wikidata":"https://www.wikidata.org/wiki/Q5165881","display_name":"Control reconfiguration","level":2,"score":0.26170000433921814},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.250900000333786}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon58223.2025.11221158","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon58223.2025.11221158","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2025 \u2013 51st Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":18,"referenced_works":["https://openalex.org/W1977233074","https://openalex.org/W2004036372","https://openalex.org/W2019129263","https://openalex.org/W2021836804","https://openalex.org/W2316964482","https://openalex.org/W2320744961","https://openalex.org/W2344518897","https://openalex.org/W2741257184","https://openalex.org/W2768157684","https://openalex.org/W2770722989","https://openalex.org/W2774416629","https://openalex.org/W2969424952","https://openalex.org/W2971758057","https://openalex.org/W3018327636","https://openalex.org/W3077869344","https://openalex.org/W4394862846","https://openalex.org/W4403676218","https://openalex.org/W4409561463"],"related_works":[],"abstract_inverted_index":{"Direct":[0],"current":[1,32,65,113],"(DC)":[2],"power":[3,25,61,165],"grids":[4],"are":[5],"well-suited":[6],"for":[7,109,160],"long-distance,":[8],"high-capacity":[9],"transmission":[10],"due":[11],"to":[12,139],"their":[13,110],"high":[14],"reliability":[15],"and":[16,28,67,85,132,136,144,154],"system":[17],"redundancy.":[18],"However,":[19],"technical":[20],"challenges":[21],"such":[22],"as":[23],"limited":[24],"flow":[26,62],"control":[27,58],"difficulty":[29],"in":[30,163],"fault":[31,64,68,103,117,142],"limitation":[33],"remain.":[34],"This":[35],"paper":[36],"proposes":[37],"a":[38,51,73,100],"compact":[39],"integrated":[40],"topology":[41,71],"combining":[42],"an":[43],"Interline":[44],"DC":[45,52,74,164],"Power":[46],"Flow":[47],"Controller":[48],"(IDCPFC)":[49],"with":[50,77,105],"Circuit":[53],"Breaker":[54],"(DCCB).":[55],"Coordinated":[56],"switching":[57],"enables":[59],"simultaneous":[60],"regulation,":[63],"limitation,":[66],"isolation.":[69],"The":[70,116,148],"adopts":[72],"circulating-current-coupled":[75],"structure":[76],"full-bridge":[78],"submodules,":[79],"achieving":[80],"efficient":[81],"regulation":[82],"under":[83],"high-voltage":[84],"large-capacity":[86],"conditions":[87],"while":[88],"mitigating":[89],"drawbacks":[90],"of":[91,120,129],"AC-coupled":[92],"designs.":[93],"Fault":[94],"analysis":[95],"is":[96,122],"conducted":[97],"based":[98],"on":[99,112],"single-pole":[101],"grounding":[102],"model,":[104],"key":[106],"parameters":[107],"evaluated":[108],"impact":[111],"limitating":[114],"capability.":[115],"isolation":[118],"function":[119],"DCCB":[121],"achieved":[123],"by":[124],"reusing":[125],"the":[126,130,141],"existing":[127],"capacitors":[128],"IDCPFC":[131],"adding":[133],"only":[134],"thyristors":[135],"surge":[137],"arresters":[138],"form":[140],"transfer":[143],"capacitor":[145],"charge/discharge":[146],"circuits.":[147],"proposed":[149],"scheme":[150],"reduces":[151],"equipment":[152],"footprint":[153],"improves":[155],"cost-effectiveness,":[156],"offering":[157],"strong":[158],"potential":[159],"practical":[161],"application":[162],"systems.":[166]},"counts_by_year":[],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-11-06T00:00:00"}
