{"id":"https://openalex.org/W4415968672","doi":"https://doi.org/10.1109/iecon58223.2025.11220994","title":"Enhancing Hydrogen Energy Management with a TSN-Driven Scalable Smart Grid Architecture","display_name":"Enhancing Hydrogen Energy Management with a TSN-Driven Scalable Smart Grid Architecture","publication_year":2025,"publication_date":"2025-10-14","ids":{"openalex":"https://openalex.org/W4415968672","doi":"https://doi.org/10.1109/iecon58223.2025.11220994"},"language":null,"primary_location":{"id":"doi:10.1109/iecon58223.2025.11220994","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon58223.2025.11220994","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2025 \u2013 51st Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5052529197","display_name":"Veit Wiese","orcid":null},"institutions":[{"id":"https://openalex.org/I206895457","display_name":"University of Siegen","ror":"https://ror.org/02azyry73","country_code":"DE","type":"education","lineage":["https://openalex.org/I206895457"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Veit Wiese","raw_affiliation_strings":["University of Siegen,Institute for Embedded Systems,Siegen,Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Siegen,Institute for Embedded Systems,Siegen,Germany","institution_ids":["https://openalex.org/I206895457"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5061008457","display_name":"Rashed Al Amin","orcid":"https://orcid.org/0000-0001-7237-6240"},"institutions":[{"id":"https://openalex.org/I206895457","display_name":"University of Siegen","ror":"https://ror.org/02azyry73","country_code":"DE","type":"education","lineage":["https://openalex.org/I206895457"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Rashed Al Amin","raw_affiliation_strings":["University of Siegen,Institute for Embedded Systems,Siegen,Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Siegen,Institute for Embedded Systems,Siegen,Germany","institution_ids":["https://openalex.org/I206895457"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5084195691","display_name":"Roman Obermaisser","orcid":null},"institutions":[{"id":"https://openalex.org/I206895457","display_name":"University of Siegen","ror":"https://ror.org/02azyry73","country_code":"DE","type":"education","lineage":["https://openalex.org/I206895457"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Roman Obermaisser","raw_affiliation_strings":["University of Siegen,Institute for Embedded Systems,Siegen,Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Siegen,Institute for Embedded Systems,Siegen,Germany","institution_ids":["https://openalex.org/I206895457"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.33868915,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"7"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12216","display_name":"Network Time Synchronization Technologies","score":0.49950000643730164,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12216","display_name":"Network Time Synchronization Technologies","score":0.49950000643730164,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.3653999865055084,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11185","display_name":"Integrated Energy Systems Optimization","score":0.019600000232458115,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.7789000272750854},{"id":"https://openalex.org/keywords/scalability","display_name":"Scalability","score":0.6258000135421753},{"id":"https://openalex.org/keywords/interoperability","display_name":"Interoperability","score":0.6194000244140625},{"id":"https://openalex.org/keywords/energy-management","display_name":"Energy management","score":0.45089998841285706},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.4505999982357025},{"id":"https://openalex.org/keywords/energy-management-system","display_name":"Energy management system","score":0.4196999967098236},{"id":"https://openalex.org/keywords/key","display_name":"Key (lock)","score":0.41350001096725464},{"id":"https://openalex.org/keywords/industry-4.0","display_name":"Industry 4.0","score":0.37940001487731934}],"concepts":[{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.7789000272750854},{"id":"https://openalex.org/C48044578","wikidata":"https://www.wikidata.org/wiki/Q727490","display_name":"Scalability","level":2,"score":0.6258000135421753},{"id":"https://openalex.org/C20136886","wikidata":"https://www.wikidata.org/wiki/Q749647","display_name":"Interoperability","level":2,"score":0.6194000244140625},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5246000289916992},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.45089998841285706},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.4505999982357025},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.4345000088214874},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.4325000047683716},{"id":"https://openalex.org/C2781260460","wikidata":"https://www.wikidata.org/wiki/Q6139999","display_name":"Energy management system","level":4,"score":0.4196999967098236},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.41350001096725464},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.38989999890327454},{"id":"https://openalex.org/C2777986313","wikidata":"https://www.wikidata.org/wiki/Q1661989","display_name":"Industry 4.0","level":2,"score":0.37940001487731934},{"id":"https://openalex.org/C15845906","wikidata":"https://www.wikidata.org/wiki/Q1172338","display_name":"Data exchange","level":2,"score":0.36880001425743103},{"id":"https://openalex.org/C123657996","wikidata":"https://www.wikidata.org/wiki/Q12271","display_name":"Architecture","level":2,"score":0.3662000000476837},{"id":"https://openalex.org/C201995342","wikidata":"https://www.wikidata.org/wiki/Q682496","display_name":"Systems engineering","level":1,"score":0.3587999939918518},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.3328000009059906},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.311599999666214},{"id":"https://openalex.org/C98025372","wikidata":"https://www.wikidata.org/wiki/Q477538","display_name":"Systems architecture","level":3,"score":0.3091999888420105},{"id":"https://openalex.org/C193415008","wikidata":"https://www.wikidata.org/wiki/Q639681","display_name":"Network architecture","level":2,"score":0.30480000376701355},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.2953999936580658},{"id":"https://openalex.org/C106527866","wikidata":"https://www.wikidata.org/wiki/Q1489497","display_name":"Building management system","level":3,"score":0.27559998631477356},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.267300009727478},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.25609999895095825}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon58223.2025.11220994","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon58223.2025.11220994","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2025 \u2013 51st Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320335322","display_name":"European Regional Development Fund","ror":"https://ror.org/00k4n6c32"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":7,"referenced_works":["https://openalex.org/W3141194630","https://openalex.org/W3206973060","https://openalex.org/W4316659786","https://openalex.org/W4352981548","https://openalex.org/W4385192390","https://openalex.org/W4402370051","https://openalex.org/W4403758650"],"related_works":[],"abstract_inverted_index":{"The":[0,43,125],"integration":[1],"of":[2,77],"renewable":[3],"energy":[4,37,70,106,145],"and":[5,14,31,41,59,84,101,121,132],"hydrogen-based":[6],"systems":[7],"into":[8],"smart":[9,25,135],"grids":[10],"requires":[11],"a":[12,21,130],"robust":[13],"determonistic":[15],"communication":[16],"infrastructure.":[17],"This":[18,72],"study":[19],"presents":[20],"Time-Sensitive":[22],"Network":[23],"(TSN)-based":[24],"grid":[26,136],"architecture":[27,80,137],"to":[28,64,128,142],"facilitate":[29],"secure":[30],"real-time":[32],"data":[33],"exchange":[34],"between":[35],"decentralized":[36],"producers,":[38],"storage":[39],"units,":[40],"consumers.":[42],"proposed":[44,79],"framework":[45],"incorporates":[46],"key":[47],"TSN":[48],"mechanisms,":[49],"including":[50],"IEEE":[51,55,60],"802.1AS":[52],"(time":[53],"synchronization),":[54],"802.1Qbv":[56],"(traffic":[57],"shaping),":[58],"802.1CB":[61],"(fault":[62],"tolerance),":[63],"ensure":[65],"reliable":[66],"operation":[67],"in":[68],"dynamic":[69],"environments.":[71],"work":[73],"evaluates":[74],"the":[75,78,140],"feasibility":[76],"through":[81,117],"theoretical":[82],"analysis":[83],"system":[85],"modeling":[86],"as":[87,94],"an":[88],"initial":[89],"step.":[90],"Key":[91],"challenges":[92],"such":[93],"network":[95],"resilience,":[96],"compliance":[97],"with":[98,103],"IEC":[99],"61508,":[100],"interoperability":[102],"existing":[104],"industrial":[105,144],"infrastructures":[107],"are":[108],"examined.":[109],"Future":[110],"research":[111],"will":[112],"focus":[113],"on":[114],"practical":[115],"validation":[116],"fault":[118],"injection":[119],"experiments":[120],"Hardware-in-the-Loop":[122],"(HIL)":[123],"testing.":[124],"results":[126],"contribute":[127],"developing":[129],"scalable":[131],"standardized":[133],"TSN-based":[134],"that":[138],"supports":[139],"transition":[141],"hydrogen-powered":[143],"systems.":[146]},"counts_by_year":[],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-11-06T00:00:00"}
