{"id":"https://openalex.org/W4410204661","doi":"https://doi.org/10.1109/iecon55916.2024.10984332","title":"Analysis and Control of Three-Level Bidirectional DC-DC Converter for Battery Charging Application","display_name":"Analysis and Control of Three-Level Bidirectional DC-DC Converter for Battery Charging Application","publication_year":2024,"publication_date":"2024-11-03","ids":{"openalex":"https://openalex.org/W4410204661","doi":"https://doi.org/10.1109/iecon55916.2024.10984332"},"language":"en","primary_location":{"id":"doi:10.1109/iecon55916.2024.10984332","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon55916.2024.10984332","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2024 - 50th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Siripuram Yamini","orcid":null},"institutions":[{"id":"https://openalex.org/I94234084","display_name":"Indian Institute of Technology Kanpur","ror":"https://ror.org/05pjsgx75","country_code":"IN","type":"education","lineage":["https://openalex.org/I94234084"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Siripuram Yamini","raw_affiliation_strings":["Indian Institute of Technology,Department of Electrical Engineering,Kanpur,India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Indian Institute of Technology,Department of Electrical Engineering,Kanpur,India","institution_ids":["https://openalex.org/I94234084"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100508459","display_name":"Dhiraj Kumar","orcid":null},"institutions":[{"id":"https://openalex.org/I94234084","display_name":"Indian Institute of Technology Kanpur","ror":"https://ror.org/05pjsgx75","country_code":"IN","type":"education","lineage":["https://openalex.org/I94234084"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Dhiraj Kumar","raw_affiliation_strings":["Indian Institute of Technology,Department of Electrical Engineering,Kanpur,India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Indian Institute of Technology,Department of Electrical Engineering,Kanpur,India","institution_ids":["https://openalex.org/I94234084"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5102891068","display_name":"Aakash Singh","orcid":"https://orcid.org/0000-0002-6213-718X"},"institutions":[{"id":"https://openalex.org/I94234084","display_name":"Indian Institute of Technology Kanpur","ror":"https://ror.org/05pjsgx75","country_code":"IN","type":"education","lineage":["https://openalex.org/I94234084"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Aakash Singh","raw_affiliation_strings":["Indian Institute of Technology,Department of Electrical Engineering,Kanpur,India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Indian Institute of Technology,Department of Electrical Engineering,Kanpur,India","institution_ids":["https://openalex.org/I94234084"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5069333689","display_name":"Suvendu Samanta","orcid":"https://orcid.org/0000-0002-6857-0910"},"institutions":[{"id":"https://openalex.org/I94234084","display_name":"Indian Institute of Technology Kanpur","ror":"https://ror.org/05pjsgx75","country_code":"IN","type":"education","lineage":["https://openalex.org/I94234084"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Suvendu Samanta","raw_affiliation_strings":["Indian Institute of Technology,Department of Electrical Engineering,Kanpur,India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Indian Institute of Technology,Department of Electrical Engineering,Kanpur,India","institution_ids":["https://openalex.org/I94234084"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.1856,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.55258979,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.972100019454956,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.972100019454956,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9465000033378601,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.9433000087738037,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/battery","display_name":"Battery (electricity)","score":0.5931644439697266},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.5020170211791992},{"id":"https://openalex.org/keywords/forward-converter","display_name":"Forward converter","score":0.48143669962882996},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4725092351436615},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.43301936984062195},{"id":"https://openalex.org/keywords/boost-converter","display_name":"Boost converter","score":0.43155914545059204},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.337566614151001},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.33335572481155396},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.3204587996006012},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.2046372890472412},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.18925172090530396},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.17963942885398865},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.14450570940971375}],"concepts":[{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.5931644439697266},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5020170211791992},{"id":"https://openalex.org/C55118286","wikidata":"https://www.wikidata.org/wiki/Q634739","display_name":"Forward converter","level":4,"score":0.48143669962882996},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4725092351436615},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.43301936984062195},{"id":"https://openalex.org/C78336795","wikidata":"https://www.wikidata.org/wiki/Q760134","display_name":"Boost converter","level":3,"score":0.43155914545059204},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.337566614151001},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.33335572481155396},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.3204587996006012},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.2046372890472412},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.18925172090530396},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.17963942885398865},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.14450570940971375},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon55916.2024.10984332","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon55916.2024.10984332","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2024 - 50th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.6000000238418579}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W2048799881","https://openalex.org/W2102691070","https://openalex.org/W2113761147","https://openalex.org/W2124249873","https://openalex.org/W2129348065","https://openalex.org/W2134945310","https://openalex.org/W2135620883","https://openalex.org/W2137169620","https://openalex.org/W2143058961","https://openalex.org/W2144165861","https://openalex.org/W2146152751","https://openalex.org/W2901703465","https://openalex.org/W3176153855","https://openalex.org/W4211040635","https://openalex.org/W4224293844","https://openalex.org/W4362647516"],"related_works":["https://openalex.org/W2283247349","https://openalex.org/W2808568537","https://openalex.org/W3115065686","https://openalex.org/W2096121481","https://openalex.org/W4310353322","https://openalex.org/W2212320229","https://openalex.org/W2534811423","https://openalex.org/W2349214957","https://openalex.org/W4390045340","https://openalex.org/W2380177640"],"abstract_inverted_index":{"This":[0,37],"paper":[1],"focuses":[2],"on":[3,60],"the":[4,50,53,62,77,84,99,107,113],"closed-loop":[5],"control":[6,74,115],"of":[7,52,64,87,112],"a":[8,40],"three-level":[9],"bidirectional":[10],"DC-DC":[11],"converter":[12],"(TL-BDC),":[13],"specifically":[14],"designed":[15],"for":[16,83],"charging":[17],"and":[18,32,109],"discharging":[19],"batteries":[20],"in":[21],"various":[22],"applications":[23],"involving":[24],"electric":[25],"vehicles":[26],"(EVs),":[27],"renewable":[28],"energy":[29],"systems":[30],"(RES),":[31],"uninterruptible":[33],"power":[34],"supplies":[35],"(UPS).":[36],"research":[38],"shows":[39],"comprehensive":[41],"study,":[42],"commencing":[43],"with":[44],"state":[45],"space":[46],"analysis":[47],"to":[48,61,105],"grasp":[49],"details":[51],"system":[54],"dynamics.":[55],"Subsequently,":[56],"The":[57],"study":[58],"moves":[59],"simulations":[63,95],"TL-BDC":[65,88],"using":[66,98],"MATLAB":[67],"Simulink.":[68],"In":[69],"this":[70],"phase,":[71],"proportional-integral":[72],"(PI)":[73],"mechanisms":[75],"manage":[76],"converter\u2019s":[78],"operations.":[79],"Also,":[80],"simulation":[81],"results":[82],"parallel":[85],"operation":[86],"are":[89,96],"presented.":[90],"Moreover,":[91],"controller":[92],"hardware-in-loop":[93],"(C-HIL)":[94],"performed":[97],"advanced":[100],"Typhoon":[101],"HIL":[102],"402":[103],"platform":[104],"validate":[106],"efficacy":[108],"real-world":[110],"applicability":[111],"proposed":[114],"strategies.":[116]},"counts_by_year":[{"year":2025,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
