{"id":"https://openalex.org/W4388726463","doi":"https://doi.org/10.1109/iecon51785.2023.10312374","title":"Active-Power Voltage-Support for a Microgrid Under Short-Circuits, Modelled in Complex Valued Domain","display_name":"Active-Power Voltage-Support for a Microgrid Under Short-Circuits, Modelled in Complex Valued Domain","publication_year":2023,"publication_date":"2023-10-16","ids":{"openalex":"https://openalex.org/W4388726463","doi":"https://doi.org/10.1109/iecon51785.2023.10312374"},"language":"en","primary_location":{"id":"doi:10.1109/iecon51785.2023.10312374","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon51785.2023.10312374","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2023- 49th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://hdl.handle.net/2117/407765","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5093273923","display_name":"Jos\u00e9-Ignacio I\u00f1iguez-Amigot","orcid":null},"institutions":[{"id":"https://openalex.org/I9617848","display_name":"Universitat Polit\u00e8cnica de Catalunya","ror":"https://ror.org/03mb6wj31","country_code":"ES","type":"education","lineage":["https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":true,"raw_author_name":"Jos\u00e9-Ignacio I\u00f1iguez-Amigot","raw_affiliation_strings":["Universitat Polit&#x00E8;cnica de Catalunya,Department of Electronic Engineering,Vilanova i la Geltr&#x00FA;,Spain,08800"],"affiliations":[{"raw_affiliation_string":"Universitat Polit&#x00E8;cnica de Catalunya,Department of Electronic Engineering,Vilanova i la Geltr&#x00FA;,Spain,08800","institution_ids":["https://openalex.org/I9617848"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5043251354","display_name":"Jaume Miret","orcid":"https://orcid.org/0000-0003-1175-4900"},"institutions":[{"id":"https://openalex.org/I9617848","display_name":"Universitat Polit\u00e8cnica de Catalunya","ror":"https://ror.org/03mb6wj31","country_code":"ES","type":"education","lineage":["https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Jaume Miret","raw_affiliation_strings":["Universitat Polit&#x00E8;cnica de Catalunya,Department of Electronic Engineering,Vilanova i la Geltr&#x00FA;,Spain,08800"],"affiliations":[{"raw_affiliation_string":"Universitat Polit&#x00E8;cnica de Catalunya,Department of Electronic Engineering,Vilanova i la Geltr&#x00FA;,Spain,08800","institution_ids":["https://openalex.org/I9617848"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5061814615","display_name":"Antonio Camacho","orcid":"https://orcid.org/0000-0002-0673-6452"},"institutions":[{"id":"https://openalex.org/I9617848","display_name":"Universitat Polit\u00e8cnica de Catalunya","ror":"https://ror.org/03mb6wj31","country_code":"ES","type":"education","lineage":["https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Antonio Camacho","raw_affiliation_strings":["Universitat Polit&#x00E8;cnica de Catalunya,Department of Electronic Engineering,Vilanova i la Geltr&#x00FA;,Spain,08800"],"affiliations":[{"raw_affiliation_string":"Universitat Polit&#x00E8;cnica de Catalunya,Department of Electronic Engineering,Vilanova i la Geltr&#x00FA;,Spain,08800","institution_ids":["https://openalex.org/I9617848"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5093276143","display_name":"Jos\u00e9-Pascual Chico-Villegas","orcid":"https://orcid.org/0009-0006-4453-5121"},"institutions":[{"id":"https://openalex.org/I9617848","display_name":"Universitat Polit\u00e8cnica de Catalunya","ror":"https://ror.org/03mb6wj31","country_code":"ES","type":"education","lineage":["https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Jos\u00e9-Pascual Chico-Villegas","raw_affiliation_strings":["Universitat Polit&#x00E8;cnica de Catalunya,Department of Electronic Engineering,Vilanova i la Geltr&#x00FA;,Spain,08800"],"affiliations":[{"raw_affiliation_string":"Universitat Polit&#x00E8;cnica de Catalunya,Department of Electronic Engineering,Vilanova i la Geltr&#x00FA;,Spain,08800","institution_ids":["https://openalex.org/I9617848"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5093273923"],"corresponding_institution_ids":["https://openalex.org/I9617848"],"apc_list":null,"apc_paid":null,"fwci":0.5543,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.67290816,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"7"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10768","display_name":"Electric Vehicles and Infrastructure","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9962999820709229,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.7985472679138184},{"id":"https://openalex.org/keywords/overcurrent","display_name":"Overcurrent","score":0.7170846462249756},{"id":"https://openalex.org/keywords/dispatchable-generation","display_name":"Dispatchable generation","score":0.7016034722328186},{"id":"https://openalex.org/keywords/low-voltage-ride-through","display_name":"Low voltage ride through","score":0.597592294216156},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.5711488723754883},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.5471826791763306},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5371734499931335},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.47404050827026367},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.47103267908096313},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.44946956634521484},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.44896769523620605},{"id":"https://openalex.org/keywords/overvoltage","display_name":"Overvoltage","score":0.43167123198509216},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.3921142816543579},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.38219571113586426},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3704795837402344},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.35222917795181274},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.1699180006980896}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.7985472679138184},{"id":"https://openalex.org/C47949032","wikidata":"https://www.wikidata.org/wiki/Q663542","display_name":"Overcurrent","level":3,"score":0.7170846462249756},{"id":"https://openalex.org/C85924503","wikidata":"https://www.wikidata.org/wiki/Q5282546","display_name":"Dispatchable generation","level":4,"score":0.7016034722328186},{"id":"https://openalex.org/C2780438294","wikidata":"https://www.wikidata.org/wiki/Q6693052","display_name":"Low voltage ride through","level":4,"score":0.597592294216156},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5711488723754883},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.5471826791763306},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5371734499931335},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.47404050827026367},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.47103267908096313},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.44946956634521484},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.44896769523620605},{"id":"https://openalex.org/C15703209","wikidata":"https://www.wikidata.org/wiki/Q333883","display_name":"Overvoltage","level":3,"score":0.43167123198509216},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3921142816543579},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.38219571113586426},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3704795837402344},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.35222917795181274},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.1699180006980896},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/iecon51785.2023.10312374","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon51785.2023.10312374","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2023- 49th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},{"id":"pmh:oai:upcommons.upc.edu:2117/407765","is_oa":true,"landing_page_url":"https://hdl.handle.net/2117/407765","pdf_url":null,"source":{"id":"https://openalex.org/S4210207057","display_name":"QRU Quaderns de Recerca en Urbanisme","issn_l":"2014-9689","issn":["2014-9689","2385-6777"],"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/P4310322448","host_organization_name":"Q71272178","host_organization_lineage":["https://openalex.org/P4310322448"],"host_organization_lineage_names":["Q71272178"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":{"id":"pmh:oai:upcommons.upc.edu:2117/407765","is_oa":true,"landing_page_url":"https://hdl.handle.net/2117/407765","pdf_url":null,"source":{"id":"https://openalex.org/S4210207057","display_name":"QRU Quaderns de Recerca en Urbanisme","issn_l":"2014-9689","issn":["2014-9689","2385-6777"],"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/P4310322448","host_organization_name":"Q71272178","host_organization_lineage":["https://openalex.org/P4310322448"],"host_organization_lineage_names":["Q71272178"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/conferenceObject"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.8199999928474426}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":23,"referenced_works":["https://openalex.org/W628349452","https://openalex.org/W812191155","https://openalex.org/W1970676140","https://openalex.org/W1971054096","https://openalex.org/W1977619868","https://openalex.org/W1994959046","https://openalex.org/W2095114068","https://openalex.org/W2130055347","https://openalex.org/W2477223685","https://openalex.org/W2526705526","https://openalex.org/W2549493714","https://openalex.org/W2910715377","https://openalex.org/W2967352744","https://openalex.org/W2982892789","https://openalex.org/W2998219635","https://openalex.org/W3004656966","https://openalex.org/W3022198667","https://openalex.org/W3152382171","https://openalex.org/W3196829564","https://openalex.org/W4248090748","https://openalex.org/W4312939821","https://openalex.org/W4316661317","https://openalex.org/W6632389158"],"related_works":["https://openalex.org/W2368502324","https://openalex.org/W2081710852","https://openalex.org/W3024497073","https://openalex.org/W2620926675","https://openalex.org/W2896710163","https://openalex.org/W3034608034","https://openalex.org/W3094463948","https://openalex.org/W1973117816","https://openalex.org/W1980297247","https://openalex.org/W4386857783"],"abstract_inverted_index":{"The":[0,85,103,138],"growing":[1],"number":[2],"of":[3,49,92,100,131,141,164],"electric":[4,55],"vehicles":[5,31,56],"(EVs)":[6],"connected":[7,80],"to":[8,15,24,42,64,76,81,126],"the":[9,17,43,47,66,82,119,128,154,162,165],"grid":[10,25,28],"are":[11,74],"a":[12,53,111,149],"promising":[13],"potential":[14],"support":[16,127],"overall":[18],"system":[19,44,151],"stability,":[20],"known":[21],"as":[22,35,135],"vehicle":[23],"concept.":[26],"During":[27],"faults":[29],"these":[30],"can":[32,40,57],"be":[33,146],"seen":[34],"distributed":[36,77],"dispatchable":[37],"sources":[38,95],"that":[39,73],"collaborate":[41],"restoration.":[45],"In":[46],"case":[48],"islanded":[50,86],"microgrids":[51],"under":[52],"fault,":[54],"provide":[58],"its":[59],"stored":[60],"energy":[61],"in":[62,105,118,153],"order":[63],"imitate":[65],"low":[67],"voltage":[68,94,112],"ride":[69],"through":[70],"protocols":[71],"(LVRT)":[72],"required":[75],"generation":[78],"systems":[79],"main":[83],"grid.":[84],"microgrid":[87],"tested":[88],"here":[89],"is":[90,108],"composed":[91],"grid-forming":[93],"supplying":[96,132],"different":[97],"loads,":[98],"some":[99],"them":[101],"EVs.":[102],"proposal":[104],"this":[106,142],"work":[107],"that,":[109],"during":[110],"sag":[113],"caused":[114],"by":[115,148],"an":[116],"overcurrent":[117],"system,":[120],"EVs":[121],"must":[122],"inject":[123],"active":[124],"power":[125,134],"voltage,":[129],"instead":[130],"reactive":[133],"LVRT":[136],"require.":[137],"theoretical":[139],"reasoning":[140],"new":[143],"approach":[144],"will":[145],"supported":[147],"complete":[150],"modelling":[152],"complex":[155],"valued":[156],"domain.":[157],"Selected":[158],"experimental":[159],"results":[160],"demonstrate":[161],"effectiveness":[163],"control":[166],"proposal.":[167]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":1}],"updated_date":"2026-03-20T23:20:44.827607","created_date":"2025-10-10T00:00:00"}