{"id":"https://openalex.org/W4388720926","doi":"https://doi.org/10.1109/iecon51785.2023.10312179","title":"Research on Mixed Ventilation Strategy of Qingdao Liyuan in Transition Season Based on BIM Technology","display_name":"Research on Mixed Ventilation Strategy of Qingdao Liyuan in Transition Season Based on BIM Technology","publication_year":2023,"publication_date":"2023-10-16","ids":{"openalex":"https://openalex.org/W4388720926","doi":"https://doi.org/10.1109/iecon51785.2023.10312179"},"language":"en","primary_location":{"id":"doi:10.1109/iecon51785.2023.10312179","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/iecon51785.2023.10312179","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2023- 49th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5063470939","display_name":"Xiaodan Ren","orcid":"https://orcid.org/0000-0002-0357-4515"},"institutions":[{"id":"https://openalex.org/I80143920","display_name":"Shandong University of Science and Technology","ror":"https://ror.org/04gtjhw98","country_code":"CN","type":"education","lineage":["https://openalex.org/I80143920"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xiaodan Ren","raw_affiliation_strings":["College of Civil Engineering and Architecture, Shandong University of Science and Technology,Qingdao,China","College of Civil Engineering and Architecture, Shandong University of Science and Technology, Qingdao, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"College of Civil Engineering and Architecture, Shandong University of Science and Technology,Qingdao,China","institution_ids":["https://openalex.org/I80143920"]},{"raw_affiliation_string":"College of Civil Engineering and Architecture, Shandong University of Science and Technology, Qingdao, China","institution_ids":["https://openalex.org/I80143920"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5075969408","display_name":"Hanqi Zhang","orcid":"https://orcid.org/0000-0003-4041-3021"},"institutions":[{"id":"https://openalex.org/I191208505","display_name":"Xiamen University","ror":"https://ror.org/00mcjh785","country_code":"CN","type":"education","lineage":["https://openalex.org/I191208505"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Hanqi Zhang","raw_affiliation_strings":["School of Architecture and Civil Engineering, Xiamen University,Xiamen,China","School of Architecture and Civil Engineering, Xiamen University, Xiamen, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Architecture and Civil Engineering, Xiamen University,Xiamen,China","institution_ids":["https://openalex.org/I191208505"]},{"raw_affiliation_string":"School of Architecture and Civil Engineering, Xiamen University, Xiamen, China","institution_ids":["https://openalex.org/I191208505"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5072179407","display_name":"Guannan Fu","orcid":null},"institutions":[{"id":"https://openalex.org/I80143920","display_name":"Shandong University of Science and Technology","ror":"https://ror.org/04gtjhw98","country_code":"CN","type":"education","lineage":["https://openalex.org/I80143920"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Guannan Fu","raw_affiliation_strings":["College of Civil Engineering and Architecture, Shandong University of Science and Technology,Qingdao,China","College of Civil Engineering and Architecture, Shandong University of Science and Technology, Qingdao, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"College of Civil Engineering and Architecture, Shandong University of Science and Technology,Qingdao,China","institution_ids":["https://openalex.org/I80143920"]},{"raw_affiliation_string":"College of Civil Engineering and Architecture, Shandong University of Science and Technology, Qingdao, China","institution_ids":["https://openalex.org/I80143920"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.30222854,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"33","issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9973000288009644,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9973000288009644,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11371","display_name":"Wind and Air Flow Studies","score":0.9768000245094299,"subfield":{"id":"https://openalex.org/subfields/2305","display_name":"Environmental Engineering"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10766","display_name":"Urban Heat Island Mitigation","score":0.9552000164985657,"subfield":{"id":"https://openalex.org/subfields/2305","display_name":"Environmental Engineering"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ventilation","display_name":"Ventilation (architecture)","score":0.8243420720100403},{"id":"https://openalex.org/keywords/natural-ventilation","display_name":"Natural ventilation","score":0.8081710338592529},{"id":"https://openalex.org/keywords/architectural-engineering","display_name":"Architectural engineering","score":0.6553351283073425},{"id":"https://openalex.org/keywords/hvac","display_name":"HVAC","score":0.6379566192626953},{"id":"https://openalex.org/keywords/environmental-science","display_name":"Environmental science","score":0.44919371604919434},{"id":"https://openalex.org/keywords/energy-conservation","display_name":"Energy conservation","score":0.4262147843837738},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.4167846143245697},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4089849591255188},{"id":"https://openalex.org/keywords/civil-engineering","display_name":"Civil engineering","score":0.3693157434463501},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3025158643722534},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"Air conditioning","score":0.16258209943771362},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.1321607232093811},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.09681138396263123}],"concepts":[{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.8243420720100403},{"id":"https://openalex.org/C206018219","wikidata":"https://www.wikidata.org/wiki/Q1427418","display_name":"Natural ventilation","level":3,"score":0.8081710338592529},{"id":"https://openalex.org/C170154142","wikidata":"https://www.wikidata.org/wiki/Q150737","display_name":"Architectural engineering","level":1,"score":0.6553351283073425},{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.6379566192626953},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.44919371604919434},{"id":"https://openalex.org/C520301825","wikidata":"https://www.wikidata.org/wiki/Q380170","display_name":"Energy conservation","level":2,"score":0.4262147843837738},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.4167846143245697},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4089849591255188},{"id":"https://openalex.org/C147176958","wikidata":"https://www.wikidata.org/wiki/Q77590","display_name":"Civil engineering","level":1,"score":0.3693157434463501},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3025158643722534},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.16258209943771362},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.1321607232093811},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.09681138396263123}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon51785.2023.10312179","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/iecon51785.2023.10312179","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2023- 49th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.7099999785423279}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W1999922888","https://openalex.org/W2508881121","https://openalex.org/W2599568691","https://openalex.org/W4283014771"],"related_works":["https://openalex.org/W2734612603","https://openalex.org/W2479405427","https://openalex.org/W2189319196","https://openalex.org/W4206457116","https://openalex.org/W3162842470","https://openalex.org/W2766664260","https://openalex.org/W2503901587","https://openalex.org/W2181830208","https://openalex.org/W2594715601","https://openalex.org/W2762091588"],"abstract_inverted_index":{"The":[0,109],"Liyuan":[1],"building":[2],"is":[3,92,168],"a":[4],"typical":[5],"example":[6],"of":[7,33,36,50,65,75,99,102,135,149],"the":[8,17,31,40,57,61,73,76,88,100,107,114,127,132,139,141,146,155],"modern":[9],"traditional":[10],"residential":[11],"buildings":[12],"in":[13,60,106,118,126,138],"Qingdao.":[14],"It":[15],"has":[16],"enclosed":[18],"architectural":[19,28],"form":[20,29],"and":[21,25,43,46,72,80,122,145,154,164],"unique":[22,27],"historical":[23],"style,":[24],"its":[26],"causes":[30],"contradiction":[32],"natural":[34,58,120],"ventilation":[35,59,82,97,104,116,121,143,150,157],"buildings.":[37],"Based":[38],"on":[39],"climate":[41],"characteristics":[42],"energy":[44,162,166],"conservation":[45],"emission":[47],"reduction":[48],"targets":[49],"Qingdao,":[51],"taking":[52],"Jieshuli":[53,66],"as":[54],"an":[55],"example,":[56],"current":[62],"transitional":[63],"season":[64],"was":[67,78,84],"simulated":[68],"by":[69],"VENT":[70],"software,":[71],"crux":[74],"problem":[77],"analyzed":[79],"passive":[81,103],"design":[83,105],"carried":[85],"out":[86],"for":[87],"building.":[89],"However,":[90],"it":[91],"necessary":[93],"to":[94],"add":[95],"mechanical":[96],"because":[98],"limitations":[101],"courtyard.":[108],"following":[110],"paper":[111],"will":[112],"explore":[113],"mixed":[115,156],"mode":[117],"which":[119],"HAVC":[123],"act":[124],"together":[125],"transition":[128],"season.":[129],"By":[130],"calculating":[131],"HVAC":[133],"load":[134],"each":[136],"space":[137],"building,":[140],"optimal":[142],"demand":[144],"theoretical":[147],"value":[148],"times":[151],"are":[152],"obtained,":[153],"strategy":[158],"with":[159],"relatively":[160],"low":[161],"consumption":[163],"high":[165],"efficiency":[167],"obtained.":[169]},"counts_by_year":[],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
