{"id":"https://openalex.org/W4388726639","doi":"https://doi.org/10.1109/iecon51785.2023.10312074","title":"Enhanced Model-Based Design and Optimization Method for Coupled Z-Source Circuit Breakers","display_name":"Enhanced Model-Based Design and Optimization Method for Coupled Z-Source Circuit Breakers","publication_year":2023,"publication_date":"2023-10-16","ids":{"openalex":"https://openalex.org/W4388726639","doi":"https://doi.org/10.1109/iecon51785.2023.10312074"},"language":"en","primary_location":{"id":"doi:10.1109/iecon51785.2023.10312074","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/iecon51785.2023.10312074","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2023- 49th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5076595125","display_name":"Zhi Liang","orcid":"https://orcid.org/0000-0002-4002-9719"},"institutions":[{"id":"https://openalex.org/I17145004","display_name":"Northwestern Polytechnical University","ror":"https://ror.org/01y0j0j86","country_code":"CN","type":"education","lineage":["https://openalex.org/I17145004"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Zhi Liang","raw_affiliation_strings":["Northwestern Polytechnical University,Dept.of Automation,Xi&#x0027;an,China"],"affiliations":[{"raw_affiliation_string":"Northwestern Polytechnical University,Dept.of Automation,Xi&#x0027;an,China","institution_ids":["https://openalex.org/I17145004"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5064770886","display_name":"Zhongzheng Zhou","orcid":"https://orcid.org/0000-0002-4462-7839"},"institutions":[{"id":"https://openalex.org/I17145004","display_name":"Northwestern Polytechnical University","ror":"https://ror.org/01y0j0j86","country_code":"CN","type":"education","lineage":["https://openalex.org/I17145004"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhongzheng Zhou","raw_affiliation_strings":["Northwestern Polytechnical University,Dept.of Automation,Xi&#x0027;an,China"],"affiliations":[{"raw_affiliation_string":"Northwestern Polytechnical University,Dept.of Automation,Xi&#x0027;an,China","institution_ids":["https://openalex.org/I17145004"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5000548028","display_name":"Yuqing Fei","orcid":null},"institutions":[{"id":"https://openalex.org/I17145004","display_name":"Northwestern Polytechnical University","ror":"https://ror.org/01y0j0j86","country_code":"CN","type":"education","lineage":["https://openalex.org/I17145004"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yuqing Fei","raw_affiliation_strings":["Northwestern Polytechnical University,Dept.of Automation,Xi&#x0027;an,China"],"affiliations":[{"raw_affiliation_string":"Northwestern Polytechnical University,Dept.of Automation,Xi&#x0027;an,China","institution_ids":["https://openalex.org/I17145004"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5114100206","display_name":"Yixi Yang","orcid":null},"institutions":[{"id":"https://openalex.org/I17145004","display_name":"Northwestern Polytechnical University","ror":"https://ror.org/01y0j0j86","country_code":"CN","type":"education","lineage":["https://openalex.org/I17145004"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yixi Yang","raw_affiliation_strings":["Northwestern Polytechnical University,Dept.of Automation,Xi&#x0027;an,China"],"affiliations":[{"raw_affiliation_string":"Northwestern Polytechnical University,Dept.of Automation,Xi&#x0027;an,China","institution_ids":["https://openalex.org/I17145004"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100690565","display_name":"Weilin Li","orcid":"https://orcid.org/0000-0002-7319-3611"},"institutions":[{"id":"https://openalex.org/I17145004","display_name":"Northwestern Polytechnical University","ror":"https://ror.org/01y0j0j86","country_code":"CN","type":"education","lineage":["https://openalex.org/I17145004"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Weilin Li","raw_affiliation_strings":["Northwestern Polytechnical University,Dept.of Automation,Xi&#x0027;an,China"],"affiliations":[{"raw_affiliation_string":"Northwestern Polytechnical University,Dept.of Automation,Xi&#x0027;an,China","institution_ids":["https://openalex.org/I17145004"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5076595125"],"corresponding_institution_ids":["https://openalex.org/I17145004"],"apc_list":null,"apc_paid":null,"fwci":0.3752,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.606762,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"7"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9966999888420105,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9966999888420105,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9941999912261963,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9933000206947327,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/circuit-breaker","display_name":"Circuit breaker","score":0.9061044454574585},{"id":"https://openalex.org/keywords/matlab","display_name":"MATLAB","score":0.5829374194145203},{"id":"https://openalex.org/keywords/equivalent-circuit","display_name":"Equivalent circuit","score":0.5705002546310425},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5374719500541687},{"id":"https://openalex.org/keywords/parametric-statistics","display_name":"Parametric statistics","score":0.5118786096572876},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.49108028411865234},{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.4635986387729645},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.44611456990242004},{"id":"https://openalex.org/keywords/circuit-extraction","display_name":"Circuit extraction","score":0.44227373600006104},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.293212354183197},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.27778416872024536},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.13416162133216858},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.08896595239639282}],"concepts":[{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.9061044454574585},{"id":"https://openalex.org/C2780365114","wikidata":"https://www.wikidata.org/wiki/Q169478","display_name":"MATLAB","level":2,"score":0.5829374194145203},{"id":"https://openalex.org/C23572009","wikidata":"https://www.wikidata.org/wiki/Q964981","display_name":"Equivalent circuit","level":3,"score":0.5705002546310425},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5374719500541687},{"id":"https://openalex.org/C117251300","wikidata":"https://www.wikidata.org/wiki/Q1849855","display_name":"Parametric statistics","level":2,"score":0.5118786096572876},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.49108028411865234},{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.4635986387729645},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.44611456990242004},{"id":"https://openalex.org/C26490066","wikidata":"https://www.wikidata.org/wiki/Q17006835","display_name":"Circuit extraction","level":4,"score":0.44227373600006104},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.293212354183197},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.27778416872024536},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.13416162133216858},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.08896595239639282},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon51785.2023.10312074","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/iecon51785.2023.10312074","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2023- 49th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.6700000166893005}],"awards":[{"id":"https://openalex.org/G2370639986","display_name":null,"funder_award_id":"52272403","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W2038149860","https://openalex.org/W2160345097","https://openalex.org/W2884891942","https://openalex.org/W2954966231","https://openalex.org/W3005712307","https://openalex.org/W3039078345","https://openalex.org/W3100867363","https://openalex.org/W3194443782","https://openalex.org/W4206427257","https://openalex.org/W4214569849","https://openalex.org/W4229976411","https://openalex.org/W4312991303","https://openalex.org/W4313203681","https://openalex.org/W4383220214"],"related_works":["https://openalex.org/W2181172762","https://openalex.org/W2147177175","https://openalex.org/W2129446522","https://openalex.org/W2119867448","https://openalex.org/W3128753656","https://openalex.org/W1578989561","https://openalex.org/W2098957495","https://openalex.org/W3011853359","https://openalex.org/W4249132264","https://openalex.org/W2235825637"],"abstract_inverted_index":{"DC":[0,27],"microgrid":[1],"has":[2],"been":[3],"applied":[4],"in":[5,86],"various":[6],"fields":[7],"due":[8],"to":[9,22,61,108,124],"its":[10],"high":[11],"efficiency.":[12],"The":[13,29,68],"short-circuit":[14,88],"fault":[15,89],"protection":[16],"of":[17,25,65,99,114,128],"circuit":[18,36,57,72,101,116],"breakers":[19],"is":[20,38,59,106],"significant":[21],"the":[23,26,34,55,63,66,87,96,100,110,115,126,129,133],"development":[24],"microgrid.":[28],"existing":[30],"modeling":[31,52,130],"method":[32,53,94,131],"for":[33,42,54,95],"Q-Z-Source":[35,56],"breaker":[37,58,102],"not":[39],"accurate":[40],"enough":[41],"guiding":[43],"a":[44],"model-based":[45],"design.":[46,135],"In":[47],"this":[48],"paper,":[49],"an":[50,92],"enhanced":[51],"proposed":[60,107],"improve":[62],"accuracy":[64],"modeling.":[67],"operational":[69],"principle":[70],"and":[71,112,132],"analysis":[73],"are":[74,122],"elaborated":[75],"with":[76],"mathematical":[77],"models,":[78],"which":[79],"can":[80],"provide":[81],"detailed":[82],"parametric":[83],"design":[84],"methods":[85],"transient.":[90],"Meanwhile,":[91],"optimization":[93],"total":[97],"inductance":[98],"implemented":[103],"by":[104],"MATLAB":[105],"reduce":[109],"weight":[111],"volume":[113],"breaker.":[117],"Finally,":[118],"Saber-based":[119],"simulation":[120],"results":[121],"utilized":[123],"verify":[125],"effectiveness":[127],"parameters":[134]},"counts_by_year":[{"year":2024,"cited_by_count":2}],"updated_date":"2025-12-19T19:40:27.379048","created_date":"2025-10-10T00:00:00"}
