{"id":"https://openalex.org/W4388726477","doi":"https://doi.org/10.1109/iecon51785.2023.10311893","title":"Design Procedure of a 3-Phase Induction Motor-Based Ceiling Fan for Improved Efficiency","display_name":"Design Procedure of a 3-Phase Induction Motor-Based Ceiling Fan for Improved Efficiency","publication_year":2023,"publication_date":"2023-10-16","ids":{"openalex":"https://openalex.org/W4388726477","doi":"https://doi.org/10.1109/iecon51785.2023.10311893"},"language":"en","primary_location":{"id":"doi:10.1109/iecon51785.2023.10311893","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/iecon51785.2023.10311893","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2023- 49th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5113048062","display_name":"Bitata Sarkar","orcid":null},"institutions":[{"id":"https://openalex.org/I24676775","display_name":"Indian Institute of Technology Madras","ror":"https://ror.org/03v0r5n49","country_code":"IN","type":"education","lineage":["https://openalex.org/I24676775"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Bitata Sarkar","raw_affiliation_strings":["Indian Institute of Technology Madras,Electrical Engineering Dept.,Chennai,Tamil Nadu,India","Electrical Engineering Dept., Indian Institute of Technology Madras, Chennai, Tamil Nadu, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Indian Institute of Technology Madras,Electrical Engineering Dept.,Chennai,Tamil Nadu,India","institution_ids":["https://openalex.org/I24676775"]},{"raw_affiliation_string":"Electrical Engineering Dept., Indian Institute of Technology Madras, Chennai, Tamil Nadu, India","institution_ids":["https://openalex.org/I24676775"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5072597661","display_name":"Shivam Chakraborty","orcid":null},"institutions":[{"id":"https://openalex.org/I24676775","display_name":"Indian Institute of Technology Madras","ror":"https://ror.org/03v0r5n49","country_code":"IN","type":"education","lineage":["https://openalex.org/I24676775"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Shivam Chakraborty","raw_affiliation_strings":["Indian Institute of Technology Madras,Electrical Engineering Dept.,Chennai,Tamil Nadu,India","Electrical Engineering Dept., Indian Institute of Technology Madras, Chennai, Tamil Nadu, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Indian Institute of Technology Madras,Electrical Engineering Dept.,Chennai,Tamil Nadu,India","institution_ids":["https://openalex.org/I24676775"]},{"raw_affiliation_string":"Electrical Engineering Dept., Indian Institute of Technology Madras, Chennai, Tamil Nadu, India","institution_ids":["https://openalex.org/I24676775"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5007622780","display_name":"Kamalesh Hatua","orcid":"https://orcid.org/0000-0003-4871-2149"},"institutions":[{"id":"https://openalex.org/I24676775","display_name":"Indian Institute of Technology Madras","ror":"https://ror.org/03v0r5n49","country_code":"IN","type":"education","lineage":["https://openalex.org/I24676775"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Kamalesh Hatua","raw_affiliation_strings":["Indian Institute of Technology Madras,Electrical Engineering Dept.,Chennai,Tamil Nadu,India","Electrical Engineering Dept., Indian Institute of Technology Madras, Chennai, Tamil Nadu, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Indian Institute of Technology Madras,Electrical Engineering Dept.,Chennai,Tamil Nadu,India","institution_ids":["https://openalex.org/I24676775"]},{"raw_affiliation_string":"Electrical Engineering Dept., Indian Institute of Technology Madras, Chennai, Tamil Nadu, India","institution_ids":["https://openalex.org/I24676775"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5021076730","display_name":"Jitendra Veer Singh","orcid":null},"institutions":[{"id":"https://openalex.org/I4210134763","display_name":"Thrombosis Research Institute","ror":"https://ror.org/04e6jcd64","country_code":"IN","type":"nonprofit","lineage":["https://openalex.org/I4210134763"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Jitendra Veer Singh","raw_affiliation_strings":["TRIBI Systems Pvt. Ltd.,TRIBI R&#x0026;D,Bangalore,Karnataka,India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"TRIBI Systems Pvt. Ltd.,TRIBI R&#x0026;D,Bangalore,Karnataka,India","institution_ids":["https://openalex.org/I4210134763"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.1227,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.45653446,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12898","display_name":"Induction Heating and Inverter Technology","score":0.9896000027656555,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12169","display_name":"Non-Destructive Testing Techniques","score":0.9789000153541565,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ceiling","display_name":"Ceiling (cloud)","score":0.7416261434555054},{"id":"https://openalex.org/keywords/induction-motor","display_name":"Induction motor","score":0.6099777817726135},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.5725783109664917},{"id":"https://openalex.org/keywords/finite-element-method","display_name":"Finite element method","score":0.4873681664466858},{"id":"https://openalex.org/keywords/magnet","display_name":"Magnet","score":0.4749225080013275},{"id":"https://openalex.org/keywords/brushed-dc-electric-motor","display_name":"Brushed DC electric motor","score":0.4504096806049347},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.4353542923927307},{"id":"https://openalex.org/keywords/dc-motor","display_name":"DC motor","score":0.42140161991119385},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.4196704924106598},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.41003262996673584},{"id":"https://openalex.org/keywords/electric-motor","display_name":"Electric motor","score":0.37706610560417175},{"id":"https://openalex.org/keywords/ac-motor","display_name":"AC motor","score":0.3408343493938446},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.32135871052742004},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.10497570037841797},{"id":"https://openalex.org/keywords/structural-engineering","display_name":"Structural engineering","score":0.09202024340629578}],"concepts":[{"id":"https://openalex.org/C2777489069","wikidata":"https://www.wikidata.org/wiki/Q1589822","display_name":"Ceiling (cloud)","level":2,"score":0.7416261434555054},{"id":"https://openalex.org/C80962145","wikidata":"https://www.wikidata.org/wiki/Q207450","display_name":"Induction motor","level":3,"score":0.6099777817726135},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.5725783109664917},{"id":"https://openalex.org/C135628077","wikidata":"https://www.wikidata.org/wiki/Q220184","display_name":"Finite element method","level":2,"score":0.4873681664466858},{"id":"https://openalex.org/C16389437","wikidata":"https://www.wikidata.org/wiki/Q11421","display_name":"Magnet","level":2,"score":0.4749225080013275},{"id":"https://openalex.org/C2949179","wikidata":"https://www.wikidata.org/wiki/Q588523","display_name":"Brushed DC electric motor","level":4,"score":0.4504096806049347},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.4353542923927307},{"id":"https://openalex.org/C76684090","wikidata":"https://www.wikidata.org/wiki/Q3842034","display_name":"DC motor","level":2,"score":0.42140161991119385},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4196704924106598},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.41003262996673584},{"id":"https://openalex.org/C176871988","wikidata":"https://www.wikidata.org/wiki/Q72313","display_name":"Electric motor","level":2,"score":0.37706610560417175},{"id":"https://openalex.org/C173161252","wikidata":"https://www.wikidata.org/wiki/Q1435839","display_name":"AC motor","level":3,"score":0.3408343493938446},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.32135871052742004},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.10497570037841797},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.09202024340629578}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon51785.2023.10311893","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/iecon51785.2023.10311893","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2023- 49th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.8100000023841858}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":7,"referenced_works":["https://openalex.org/W2028436550","https://openalex.org/W2159644830","https://openalex.org/W2498991536","https://openalex.org/W2944578742","https://openalex.org/W3143915571","https://openalex.org/W4206479659","https://openalex.org/W4224927304"],"related_works":["https://openalex.org/W2201810838","https://openalex.org/W2356469784","https://openalex.org/W2912746909","https://openalex.org/W1626739846","https://openalex.org/W3012683504","https://openalex.org/W2082750424","https://openalex.org/W111560823","https://openalex.org/W51549025","https://openalex.org/W2182323609","https://openalex.org/W2541760750"],"abstract_inverted_index":{"Single-Phase":[0],"Induction":[1],"Motors":[2,20],"(SPIMs)":[3],"have":[4],"dominated":[5],"the":[6,23,32,40,75,104,114,118,131,152],"ceiling":[7,65,80,155],"fan":[8,66,81,156],"industry":[9],"for":[10,31],"many":[11],"years.":[12],"Recently":[13],"Permanent":[14],"Magnet":[15],"Brushless":[16],"Direct":[17],"Current":[18],"(PMBLDC)":[19],"took":[21],"over":[22],"market":[24],"owing":[25],"to":[26,73],"their":[27],"low":[28,51],"power":[29,106],"consumption":[30],"same":[33,105],"air":[34],"delivery":[35],"as":[36],"SPIMs,":[37],"complying":[38],"with":[39,103],"Bureau":[41],"of":[42,77,117,127],"Energy":[43],"Efficiency":[44],"(BEE)":[45],"regulations.":[46],"Despite":[47],"having":[48],"simple,":[49],"rugged,":[50],"cost":[52,98],"and":[53,95,124,160],"maintenance-friendly":[54],"properties,":[55],"three-phase":[56],"induction":[57],"motor":[58,157],"(IM)":[59],"has":[60],"never":[61],"been":[62],"used":[63],"in":[64,133],"applications.":[67],"This":[68],"paper":[69,135],"presents":[70],"design":[71],"procedures":[72],"maximise":[74],"efficiency":[76,92,110],"IM":[78,89],"-based":[79],"motors":[82,102],"mostly":[83],"by":[84,113,138],"optimal":[85],"magnetic":[86,119],"material":[87],"usage.":[88],"provides":[90],"better":[91,97],"than":[93,100],"SPIM":[94],"a":[96],"profile":[99],"PMBLDC":[101],"input.":[107],"The":[108],"improved":[109],"is":[111,158],"achieved":[112],"effective":[115],"usage":[116],"circuit,":[120],"proper":[121,125],"copper":[122],"utilisation,":[123],"selection":[126],"pole":[128],"numbers.":[129],"All":[130],"designs":[132],"this":[134],"are":[136],"validated":[137],"Finite":[139],"Element":[140],"Method":[141],"Magnetics":[142],"(FEMM),":[143],"an":[144],"open-source":[145],"finite":[146],"element":[147],"analysis":[148],"(FEA)":[149],"software.":[150],"Also,":[151],"designed":[153],"IM-based":[154],"manufactured":[159],"tested":[161],"successfully.":[162]},"counts_by_year":[{"year":2024,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
