{"id":"https://openalex.org/W4310929529","doi":"https://doi.org/10.1109/iecon49645.2022.9969037","title":"A Stator Flux Linkage DC Offset Based Stator Fault Detection For PMSM Drive Systems","display_name":"A Stator Flux Linkage DC Offset Based Stator Fault Detection For PMSM Drive Systems","publication_year":2022,"publication_date":"2022-10-17","ids":{"openalex":"https://openalex.org/W4310929529","doi":"https://doi.org/10.1109/iecon49645.2022.9969037"},"language":"en","primary_location":{"id":"doi:10.1109/iecon49645.2022.9969037","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon49645.2022.9969037","pdf_url":null,"source":{"id":"https://openalex.org/S4363607717","display_name":"IECON 2022 \u2013 48th Annual Conference of the IEEE Industrial Electronics Society","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2022 \u2013 48th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5085981860","display_name":"Akanksha Upadhyay","orcid":null},"institutions":[{"id":"https://openalex.org/I187531555","display_name":"Lund University","ror":"https://ror.org/012a77v79","country_code":"SE","type":"education","lineage":["https://openalex.org/I187531555"]}],"countries":["SE"],"is_corresponding":true,"raw_author_name":"Akanksha Upadhyay","raw_affiliation_strings":["Lund University,Div. of Industrial Electrical Engineering and Automation,Lund,Sweden,22100"],"affiliations":[{"raw_affiliation_string":"Lund University,Div. of Industrial Electrical Engineering and Automation,Lund,Sweden,22100","institution_ids":["https://openalex.org/I187531555"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5023964770","display_name":"Mats Alak\u00fcla","orcid":"https://orcid.org/0000-0002-3227-2954"},"institutions":[{"id":"https://openalex.org/I187531555","display_name":"Lund University","ror":"https://ror.org/012a77v79","country_code":"SE","type":"education","lineage":["https://openalex.org/I187531555"]}],"countries":["SE"],"is_corresponding":false,"raw_author_name":"Mats Alakula","raw_affiliation_strings":["Lund University,Div. of Industrial Electrical Engineering and Automation,Lund,Sweden,22100","Swedish Electromobility Centre, Gothenburg, Sweden"],"affiliations":[{"raw_affiliation_string":"Lund University,Div. of Industrial Electrical Engineering and Automation,Lund,Sweden,22100","institution_ids":["https://openalex.org/I187531555"]},{"raw_affiliation_string":"Swedish Electromobility Centre, Gothenburg, Sweden","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5085981860"],"corresponding_institution_ids":["https://openalex.org/I187531555"],"apc_list":null,"apc_paid":null,"fwci":0.3538,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.46137513,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"7"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.9973000288009644,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9939000010490417,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/stator","display_name":"Stator","score":0.9488059282302856},{"id":"https://openalex.org/keywords/flux-linkage","display_name":"Flux linkage","score":0.8216872215270996},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.7291967272758484},{"id":"https://openalex.org/keywords/offset","display_name":"Offset (computer science)","score":0.7111896276473999},{"id":"https://openalex.org/keywords/electromagnetic-coil","display_name":"Electromagnetic coil","score":0.608925461769104},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.5192223191261292},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4514722228050232},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.4245555102825165},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.41514521837234497},{"id":"https://openalex.org/keywords/induction-motor","display_name":"Induction motor","score":0.2350497543811798},{"id":"https://openalex.org/keywords/direct-torque-control","display_name":"Direct torque control","score":0.18773722648620605},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.09130895137786865},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.07437261939048767},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.05852392315864563},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.0561787486076355}],"concepts":[{"id":"https://openalex.org/C2776529397","wikidata":"https://www.wikidata.org/wiki/Q190312","display_name":"Stator","level":2,"score":0.9488059282302856},{"id":"https://openalex.org/C155343825","wikidata":"https://www.wikidata.org/wiki/Q4374882","display_name":"Flux linkage","level":5,"score":0.8216872215270996},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.7291967272758484},{"id":"https://openalex.org/C175291020","wikidata":"https://www.wikidata.org/wiki/Q1156822","display_name":"Offset (computer science)","level":2,"score":0.7111896276473999},{"id":"https://openalex.org/C30403606","wikidata":"https://www.wikidata.org/wiki/Q2981904","display_name":"Electromagnetic coil","level":2,"score":0.608925461769104},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.5192223191261292},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4514722228050232},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4245555102825165},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.41514521837234497},{"id":"https://openalex.org/C80962145","wikidata":"https://www.wikidata.org/wiki/Q207450","display_name":"Induction motor","level":3,"score":0.2350497543811798},{"id":"https://openalex.org/C109871850","wikidata":"https://www.wikidata.org/wiki/Q1227571","display_name":"Direct torque control","level":4,"score":0.18773722648620605},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.09130895137786865},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.07437261939048767},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.05852392315864563},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.0561787486076355},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon49645.2022.9969037","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon49645.2022.9969037","pdf_url":null,"source":{"id":"https://openalex.org/S4363607717","display_name":"IECON 2022 \u2013 48th Annual Conference of the IEEE Industrial Electronics Society","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2022 \u2013 48th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":9,"referenced_works":["https://openalex.org/W1977202657","https://openalex.org/W1990221908","https://openalex.org/W2142632891","https://openalex.org/W2158499370","https://openalex.org/W2171874489","https://openalex.org/W2180731300","https://openalex.org/W2519918482","https://openalex.org/W2783299598","https://openalex.org/W2995661796"],"related_works":["https://openalex.org/W2562427298","https://openalex.org/W623794290","https://openalex.org/W4285792754","https://openalex.org/W2372255233","https://openalex.org/W2361693169","https://openalex.org/W2130828945","https://openalex.org/W3016722916","https://openalex.org/W2135587218","https://openalex.org/W2362940978","https://openalex.org/W4310929529"],"abstract_inverted_index":{"The":[0,62,92,142,159],"main":[1],"focus":[2],"of":[3,10,13,17,50,65,110,161,169],"this":[4,28],"paper":[5],"is":[6,34,44,71,102,118,140,146,165],"to":[7,84,120,150],"establish":[8],"diagnostics":[9],"stator":[11,15,41,79,96,111,123,136],"faults":[12],"the":[14,37,40,47,51,57,66,69,75,78,105,132,162],"windings":[16],"a":[18,30,135],"Permanent":[19],"Magnet":[20],"Synchronous":[21],"Machine":[22],"(PMSM)":[23],"drive":[24],"system.":[25],"To":[26],"accomplish":[27],"objective,":[29],"simplified":[31],"diagnostic":[32,93,144],"method":[33],"proposed.":[35],"In":[36],"proposed":[38,133,143,163],"method,":[39,134],"fault":[42,124,137,153],"detection":[43],"based":[45],"on":[46],"dc":[48],"offset":[49,64,100],"Stator":[52],"Flux":[53],"Linkage":[54],"(SFL)":[55],"in":[56,68,77],"antisynchronous":[58],"reference":[59,80],"frame":[60],"(ASRF).":[61],"DC":[63,99],"SFL":[67,76],"ASRF":[70,86],"calculated":[72],"by":[73,167],"estimating":[74],"frame,":[81],"transforming":[82],"it":[83,117],"an":[85],"and":[87,108,128,148,172],"low":[88],"pass":[89],"filtering":[90],"it.":[91],"parameter":[94],"namely":[95],"flux":[97],"linkage":[98],"(SFDO)":[101],"robust":[103],"against":[104],"operating":[106,157],"conditions":[107],"type":[109],"connection":[112],"(star":[113],"or":[114],"delta).":[115],"Additionally,":[116],"able":[119],"diagnose":[121],"both":[122,170],"existence,":[125],"its":[126],"location":[127],"related":[129],"phase.":[130],"With":[131],"monitoring":[138],"system":[139],"realised.":[141],"model":[145],"simulated":[147,171],"tested":[149],"study":[151],"PMSM":[152],"behavior":[154],"under":[155],"different":[156],"conditions.":[158],"validity":[160],"approach":[164],"verified":[166],"means":[168],"experimental":[173],"results.":[174]},"counts_by_year":[{"year":2023,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
