{"id":"https://openalex.org/W3211713784","doi":"https://doi.org/10.1109/iecon48115.2021.9589202","title":"A new time scale based energy management strategy for a hybrid energy storage system in electrical microgrids","display_name":"A new time scale based energy management strategy for a hybrid energy storage system in electrical microgrids","publication_year":2021,"publication_date":"2021-10-13","ids":{"openalex":"https://openalex.org/W3211713784","doi":"https://doi.org/10.1109/iecon48115.2021.9589202","mag":"3211713784"},"language":"en","primary_location":{"id":"doi:10.1109/iecon48115.2021.9589202","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon48115.2021.9589202","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2021 \u2013 47th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5112752036","display_name":"Mohamed Mroueh","orcid":"https://orcid.org/0009-0003-1463-045X"},"institutions":[{"id":"https://openalex.org/I4392021119","display_name":"Institut de Recherche en Energie Electrique de Nantes Atlantique","ror":"https://ror.org/00z2bca79","country_code":"FR","type":"facility","lineage":["https://openalex.org/I4392021119","https://openalex.org/I97188460"]},{"id":"https://openalex.org/I49451733","display_name":"Universit\u00e9 d'Angers","ror":"https://ror.org/04yrqp957","country_code":"FR","type":"education","lineage":["https://openalex.org/I49451733"]},{"id":"https://openalex.org/I97188460","display_name":"Nantes Universit\u00e9","ror":"https://ror.org/03gnr7b55","country_code":"FR","type":"education","lineage":["https://openalex.org/I97188460"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Mohamed Mroueh","raw_affiliation_strings":["ESEO Tech - IREENA Lab EA 4642, Universit\u00e9 d\u2019Angers, Angers, France","ESEO Tech - IREENA Lab EA 4642, Universit\u00e9 d'Angers, Angers, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"ESEO Tech - IREENA Lab EA 4642, Universit\u00e9 d\u2019Angers, Angers, France","institution_ids":["https://openalex.org/I4392021119","https://openalex.org/I49451733","https://openalex.org/I97188460"]},{"raw_affiliation_string":"ESEO Tech - IREENA Lab EA 4642, Universit\u00e9 d'Angers, Angers, France","institution_ids":["https://openalex.org/I4392021119","https://openalex.org/I49451733","https://openalex.org/I97188460"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5016281678","display_name":"Sarah Kassir","orcid":null},"institutions":[{"id":"https://openalex.org/I4392021119","display_name":"Institut de Recherche en Energie Electrique de Nantes Atlantique","ror":"https://ror.org/00z2bca79","country_code":"FR","type":"facility","lineage":["https://openalex.org/I4392021119","https://openalex.org/I97188460"]},{"id":"https://openalex.org/I49451733","display_name":"Universit\u00e9 d'Angers","ror":"https://ror.org/04yrqp957","country_code":"FR","type":"education","lineage":["https://openalex.org/I49451733"]},{"id":"https://openalex.org/I97188460","display_name":"Nantes Universit\u00e9","ror":"https://ror.org/03gnr7b55","country_code":"FR","type":"education","lineage":["https://openalex.org/I97188460"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Sarah Kassir","raw_affiliation_strings":["ESEO Tech - IREENA Lab EA 4642, Universit\u00e9 d\u2019Angers, Angers, France","ESEO Tech - IREENA Lab EA 4642, Universit\u00e9 d'Angers, Angers, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"ESEO Tech - IREENA Lab EA 4642, Universit\u00e9 d\u2019Angers, Angers, France","institution_ids":["https://openalex.org/I4392021119","https://openalex.org/I49451733","https://openalex.org/I97188460"]},{"raw_affiliation_string":"ESEO Tech - IREENA Lab EA 4642, Universit\u00e9 d'Angers, Angers, France","institution_ids":["https://openalex.org/I4392021119","https://openalex.org/I49451733","https://openalex.org/I97188460"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5045722164","display_name":"Moustapha Doumiati","orcid":"https://orcid.org/0000-0001-7145-9693"},"institutions":[{"id":"https://openalex.org/I4210149659","display_name":"\u00c9cole Sup\u00e9rieure d'\u00c9lectronique de l'Ouest","ror":"https://ror.org/04nx9ps90","country_code":"FR","type":"education","lineage":["https://openalex.org/I4210149659"]},{"id":"https://openalex.org/I4392021119","display_name":"Institut de Recherche en Energie Electrique de Nantes Atlantique","ror":"https://ror.org/00z2bca79","country_code":"FR","type":"facility","lineage":["https://openalex.org/I4392021119","https://openalex.org/I97188460"]},{"id":"https://openalex.org/I97188460","display_name":"Nantes Universit\u00e9","ror":"https://ror.org/03gnr7b55","country_code":"FR","type":"education","lineage":["https://openalex.org/I97188460"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Moustapha Doumiati","raw_affiliation_strings":["ESEO Tech - IREENA Lab EA 4642, Ecole Sup\u00e9rieure d\u2019Electronique de l\u2019Ouest, Angers, France","ESEO Tech - IREENA Lab EA 4642, Ecole Sup\u00e9rieure d'Electronique de l'Ouest, Angers, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"ESEO Tech - IREENA Lab EA 4642, Ecole Sup\u00e9rieure d\u2019Electronique de l\u2019Ouest, Angers, France","institution_ids":["https://openalex.org/I4210149659","https://openalex.org/I4392021119","https://openalex.org/I97188460"]},{"raw_affiliation_string":"ESEO Tech - IREENA Lab EA 4642, Ecole Sup\u00e9rieure d'Electronique de l'Ouest, Angers, France","institution_ids":["https://openalex.org/I4210149659","https://openalex.org/I4392021119","https://openalex.org/I97188460"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5112144379","display_name":"Clovis Francis","orcid":null},"institutions":[{"id":"https://openalex.org/I160368002","display_name":"Lebanese University","ror":"https://ror.org/05x6qnc69","country_code":"LB","type":"education","lineage":["https://openalex.org/I160368002"]}],"countries":["LB"],"is_corresponding":false,"raw_author_name":"Clovis Francis","raw_affiliation_strings":["Faculty of engineering - Branch I, Lebanese University, Lebanon"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Faculty of engineering - Branch I, Lebanese University, Lebanon","institution_ids":["https://openalex.org/I160368002"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5016823513","display_name":"Mohamed Machmoum","orcid":"https://orcid.org/0000-0002-0996-0417"},"institutions":[{"id":"https://openalex.org/I4392021119","display_name":"Institut de Recherche en Energie Electrique de Nantes Atlantique","ror":"https://ror.org/00z2bca79","country_code":"FR","type":"facility","lineage":["https://openalex.org/I4392021119","https://openalex.org/I97188460"]},{"id":"https://openalex.org/I97188460","display_name":"Nantes Universit\u00e9","ror":"https://ror.org/03gnr7b55","country_code":"FR","type":"education","lineage":["https://openalex.org/I97188460"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Mohamed Machmoum","raw_affiliation_strings":["IREENA Lab EA 4642, Universit\u00e9 de Nantes, Saint Nazaire, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"IREENA Lab EA 4642, Universit\u00e9 de Nantes, Saint Nazaire, France","institution_ids":["https://openalex.org/I4392021119","https://openalex.org/I97188460"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.35,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.78661664,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11392","display_name":"Energy Harvesting in Wireless Networks","score":0.998199999332428,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.7939664125442505},{"id":"https://openalex.org/keywords/component","display_name":"Component (thermodynamics)","score":0.7277038097381592},{"id":"https://openalex.org/keywords/energy-storage","display_name":"Energy storage","score":0.6754410266876221},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6302269697189331},{"id":"https://openalex.org/keywords/energy-management","display_name":"Energy management","score":0.5669452548027039},{"id":"https://openalex.org/keywords/energy-management-system","display_name":"Energy management system","score":0.5393739342689514},{"id":"https://openalex.org/keywords/limiter","display_name":"Limiter","score":0.5314978957176208},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.49539124965667725},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.4901605546474457},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4526313841342926},{"id":"https://openalex.org/keywords/reduction","display_name":"Reduction (mathematics)","score":0.4429033398628235},{"id":"https://openalex.org/keywords/computer-data-storage","display_name":"Computer data storage","score":0.43550243973731995},{"id":"https://openalex.org/keywords/scale","display_name":"Scale (ratio)","score":0.42924314737319946},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.4129529595375061},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.3589034676551819},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.35797619819641113},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.1763562560081482},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.09969022870063782},{"id":"https://openalex.org/keywords/computer-hardware","display_name":"Computer hardware","score":0.08958664536476135},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.07340875267982483}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.7939664125442505},{"id":"https://openalex.org/C168167062","wikidata":"https://www.wikidata.org/wiki/Q1117970","display_name":"Component (thermodynamics)","level":2,"score":0.7277038097381592},{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.6754410266876221},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6302269697189331},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.5669452548027039},{"id":"https://openalex.org/C2781260460","wikidata":"https://www.wikidata.org/wiki/Q6139999","display_name":"Energy management system","level":4,"score":0.5393739342689514},{"id":"https://openalex.org/C45011657","wikidata":"https://www.wikidata.org/wiki/Q1613840","display_name":"Limiter","level":2,"score":0.5314978957176208},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.49539124965667725},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4901605546474457},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4526313841342926},{"id":"https://openalex.org/C111335779","wikidata":"https://www.wikidata.org/wiki/Q3454686","display_name":"Reduction (mathematics)","level":2,"score":0.4429033398628235},{"id":"https://openalex.org/C194739806","wikidata":"https://www.wikidata.org/wiki/Q66221","display_name":"Computer data storage","level":2,"score":0.43550243973731995},{"id":"https://openalex.org/C2778755073","wikidata":"https://www.wikidata.org/wiki/Q10858537","display_name":"Scale (ratio)","level":2,"score":0.42924314737319946},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.4129529595375061},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3589034676551819},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.35797619819641113},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.1763562560081482},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.09969022870063782},{"id":"https://openalex.org/C9390403","wikidata":"https://www.wikidata.org/wiki/Q3966","display_name":"Computer hardware","level":1,"score":0.08958664536476135},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.07340875267982483},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/iecon48115.2021.9589202","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon48115.2021.9589202","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2021 \u2013 47th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},{"id":"pmh:oai:HAL:hal-05028306v1","is_oa":false,"landing_page_url":"https://hal.science/hal-05028306","pdf_url":null,"source":{"id":"https://openalex.org/S4306402512","display_name":"HAL (Le Centre pour la Communication Scientifique Directe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1294671590","host_organization_name":"Centre National de la Recherche Scientifique","host_organization_lineage":["https://openalex.org/I1294671590"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IECON 2021 - 47th Annual Conference of the IEEE Industrial Electronics Society, Oct 2021, Toronto, Canada. pp.1-6, &#x27E8;10.1109/IECON48115.2021.9589202&#x27E9;","raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.8999999761581421}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":22,"referenced_works":["https://openalex.org/W1535593359","https://openalex.org/W1699476055","https://openalex.org/W1829950752","https://openalex.org/W1857647639","https://openalex.org/W1985969841","https://openalex.org/W2013065953","https://openalex.org/W2019681626","https://openalex.org/W2035463670","https://openalex.org/W2071871395","https://openalex.org/W2072778096","https://openalex.org/W2082291889","https://openalex.org/W2116449881","https://openalex.org/W2300835437","https://openalex.org/W2342888439","https://openalex.org/W2476840567","https://openalex.org/W2507165301","https://openalex.org/W2525247567","https://openalex.org/W2616085178","https://openalex.org/W2796445275","https://openalex.org/W2889629837","https://openalex.org/W2999275926","https://openalex.org/W3005574788"],"related_works":["https://openalex.org/W2333017163","https://openalex.org/W2964937504","https://openalex.org/W2169268775","https://openalex.org/W2749199243","https://openalex.org/W4366813529","https://openalex.org/W4220876800","https://openalex.org/W2333530803","https://openalex.org/W2133545517","https://openalex.org/W2347673489","https://openalex.org/W2371966636"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"a":[3,17,63,75],"new":[4],"Energy":[5,12],"Management":[6],"System":[7,14],"(EMS)":[8],"strategy":[9],"for":[10,105,117],"the":[11,22,40,94,109],"Storage":[13],"(ESS)":[15],"of":[16,26,39,103,111,113],"Microgrid":[18],"(MG)":[19],"based":[20],"on":[21,50,66],"proper":[23],"time":[24],"scale":[25],"each":[27],"ESS":[28,42],"component.":[29,119],"The":[30,80],"theoretical":[31],"framework":[32],"allows":[33],"to":[34,55,93],"achieve":[35,56],"more":[36],"efficient":[37],"use":[38],"different":[41],"components\u2019.":[43],"While":[44],"almost":[45],"all":[46],"existing":[47],"methods":[48],"rely":[49],"filtering":[51],"load":[52],"profile":[53],"signals":[54],"power":[57],"separation,":[58],"our":[59],"proposed":[60,81],"approach":[61],"achieves":[62],"better":[64],"performance":[65],"components\u2019":[67],"ageing":[68,100,114],"rate":[69,101,115],"with":[70],"less":[71],"processing":[72],"complexity":[73],"using":[74],"simple":[76],"limiter":[77],"in":[78],"algorithm.":[79],"method":[82],"is":[83],"first":[84],"evaluated":[85],"as":[86],"an":[87,99],"EMS":[88],"only":[89],"and":[90],"then":[91],"extended":[92],"whole":[95],"MG.":[96],"Results":[97],"show":[98],"reduction":[102],"93%":[104],"fast":[106],"component":[107],"at":[108],"price":[110],"24%":[112],"increase":[116],"slow":[118]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":1}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}