{"id":"https://openalex.org/W2996234932","doi":"https://doi.org/10.1109/iecon.2019.8927644","title":"Loss Model for Improved Efficiency Characterization of DC Coupled PV-Battery System Converters","display_name":"Loss Model for Improved Efficiency Characterization of DC Coupled PV-Battery System Converters","publication_year":2019,"publication_date":"2019-10-01","ids":{"openalex":"https://openalex.org/W2996234932","doi":"https://doi.org/10.1109/iecon.2019.8927644","mag":"2996234932"},"language":"en","primary_location":{"id":"doi:10.1109/iecon.2019.8927644","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2019.8927644","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2019 - 45th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5002690487","display_name":"Jolien Despeghel","orcid":"https://orcid.org/0000-0001-9296-0081"},"institutions":[{"id":"https://openalex.org/I99464096","display_name":"KU Leuven","ror":"https://ror.org/05f950310","country_code":"BE","type":"education","lineage":["https://openalex.org/I99464096"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"Jolien Despeghel","raw_affiliation_strings":["Department of Electrical Engineering (ESAT-ELECTA), KU Leuven - EnergyVille, Leuven, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering (ESAT-ELECTA), KU Leuven - EnergyVille, Leuven, Belgium","institution_ids":["https://openalex.org/I99464096"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5105922898","display_name":"Jeroen Tant","orcid":"https://orcid.org/0000-0002-3516-4633"},"institutions":[{"id":"https://openalex.org/I99464096","display_name":"KU Leuven","ror":"https://ror.org/05f950310","country_code":"BE","type":"education","lineage":["https://openalex.org/I99464096"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"Jeroen Tant","raw_affiliation_strings":["Department of Electrical Engineering (ESAT-ELECTA), KU Leuven - EnergyVille, Leuven, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering (ESAT-ELECTA), KU Leuven - EnergyVille, Leuven, Belgium","institution_ids":["https://openalex.org/I99464096"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5027002529","display_name":"Johan Driesen","orcid":"https://orcid.org/0000-0002-1025-0949"},"institutions":[{"id":"https://openalex.org/I99464096","display_name":"KU Leuven","ror":"https://ror.org/05f950310","country_code":"BE","type":"education","lineage":["https://openalex.org/I99464096"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"Johan Driesen","raw_affiliation_strings":["Department of Electrical Engineering (ESAT-ELECTA), KU Leuven - EnergyVille, Leuven, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering (ESAT-ELECTA), KU Leuven - EnergyVille, Leuven, Belgium","institution_ids":["https://openalex.org/I99464096"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I99464096"],"apc_list":null,"apc_paid":null,"fwci":0.2422,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.57716571,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"4740","last_page":"4745"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10663","display_name":"Advanced Battery Technologies Research","score":0.9979000091552734,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/datasheet","display_name":"Datasheet","score":0.9822580814361572},{"id":"https://openalex.org/keywords/photovoltaic-system","display_name":"Photovoltaic system","score":0.7893065214157104},{"id":"https://openalex.org/keywords/battery","display_name":"Battery (electricity)","score":0.6184788942337036},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6034497022628784},{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.5700611472129822},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.5506141781806946},{"id":"https://openalex.org/keywords/energy-storage","display_name":"Energy storage","score":0.43946823477745056},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.4085320830345154},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.3451356589794159},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.31281328201293945},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.2845900058746338},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.24481850862503052}],"concepts":[{"id":"https://openalex.org/C2781384022","wikidata":"https://www.wikidata.org/wiki/Q1172383","display_name":"Datasheet","level":2,"score":0.9822580814361572},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.7893065214157104},{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.6184788942337036},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6034497022628784},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.5700611472129822},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.5506141781806946},{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.43946823477745056},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4085320830345154},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3451356589794159},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.31281328201293945},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.2845900058746338},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.24481850862503052},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon.2019.8927644","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2019.8927644","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2019 - 45th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.8999999761581421,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W96924397","https://openalex.org/W1540107832","https://openalex.org/W1987317203","https://openalex.org/W2025065409","https://openalex.org/W2032345775","https://openalex.org/W2051804398","https://openalex.org/W2055806467","https://openalex.org/W2123424645","https://openalex.org/W2302958356","https://openalex.org/W2342131056","https://openalex.org/W2778720317","https://openalex.org/W6704250516","https://openalex.org/W6910549153","https://openalex.org/W6944911617"],"related_works":["https://openalex.org/W2572450784","https://openalex.org/W2098558496","https://openalex.org/W4245685577","https://openalex.org/W2291072988","https://openalex.org/W3082523300","https://openalex.org/W1496483304","https://openalex.org/W2019790852","https://openalex.org/W2059629300","https://openalex.org/W2790844566","https://openalex.org/W153570363"],"abstract_inverted_index":{"The":[0,32,80,102],"use":[1],"of":[2,18,63,84,110,116],"battery":[3],"energy":[4,30],"storage":[5],"systems":[6],"(BESS)":[7],"is":[8,78,145],"emerging":[9],"in":[10,28,57,69,114],"residential":[11],"settings,":[12],"complementary":[13],"to":[14,94,147],"the":[15,39,43,48,60,64,108,111,124,134,139],"existing":[16],"presence":[17],"photovoltaic":[19],"(PV)":[20],"systems.":[21],"BESS":[22],"can":[23],"play":[24],"a":[25,70,85,96,128,143],"vital":[26],"role":[27],"distributed":[29],"generation.":[31],"latest":[33],"efficiency":[34,49,109],"guidelines":[35],"for":[36,50],"PV-battery":[37,73,90],"systems,":[38],"Effzienzleitfaden":[40],"presented":[41],"by":[42],"German":[44],"BVES":[45],"only":[46],"characterize":[47],"singular":[51,117],"power":[52,66,120,151],"flows,":[53],"which":[54],"falls":[55],"short":[56],"correctly":[58],"representing":[59],"operational":[61],"reality":[62],"combinatory":[65,119,150],"flows":[67],"present":[68],"DC":[71,88],"coupled":[72,89],"system.":[74],"A":[75],"loss":[76,104,130],"model":[77,105,126,131,149],"proposed.":[79],"experimental":[81,100],"case":[82],"study":[83],"commercially":[86],"available":[87,141],"converter":[91,112],"system":[92],"allows":[93],"perform":[95],"least-squares":[97],"fitting":[98],"using":[99],"measurements.":[101],"proposed":[103,125],"accurately":[106,148],"characterizes":[107],"both":[113],"modes":[115],"and":[118,127],"flows.":[121],"Comparison":[122],"between":[123],"quadratic":[129],"based":[132],"on":[133,142],"datasheet":[135,144],"has":[136],"shown":[137],"that":[138],"data":[140],"insufficient":[146],"flow":[152],"losses.":[153]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1}],"updated_date":"2026-06-26T08:34:08.712188","created_date":"2025-10-10T00:00:00"}
