{"id":"https://openalex.org/W2996554912","doi":"https://doi.org/10.1109/iecon.2019.8927519","title":"Optimal Power Setting based on Voltage Angle Controller for VSC-HVDC in Hybrid AC and DC Power Systems","display_name":"Optimal Power Setting based on Voltage Angle Controller for VSC-HVDC in Hybrid AC and DC Power Systems","publication_year":2019,"publication_date":"2019-10-01","ids":{"openalex":"https://openalex.org/W2996554912","doi":"https://doi.org/10.1109/iecon.2019.8927519","mag":"2996554912"},"language":"en","primary_location":{"id":"doi:10.1109/iecon.2019.8927519","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2019.8927519","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2019 - 45th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5011924633","display_name":"Yang Zhou","orcid":"https://orcid.org/0000-0002-1443-0672"},"institutions":[{"id":"https://openalex.org/I200332995","display_name":"TU Dortmund University","ror":"https://ror.org/01k97gp34","country_code":"DE","type":"education","lineage":["https://openalex.org/I200332995"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Yang Zhou","raw_affiliation_strings":["Energy Efficiency and Energy Economics (ie3), Institute of Energy Systems, TU Dortmund University, Dortmund, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Energy Efficiency and Energy Economics (ie3), Institute of Energy Systems, TU Dortmund University, Dortmund, Germany","institution_ids":["https://openalex.org/I200332995"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5079392631","display_name":"Stefan Dalhues","orcid":"https://orcid.org/0000-0002-2473-2201"},"institutions":[{"id":"https://openalex.org/I200332995","display_name":"TU Dortmund University","ror":"https://ror.org/01k97gp34","country_code":"DE","type":"education","lineage":["https://openalex.org/I200332995"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Stefan Dalhues","raw_affiliation_strings":["Energy Efficiency and Energy Economics (ie3), Institute of Energy Systems, TU Dortmund University, Dortmund, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Energy Efficiency and Energy Economics (ie3), Institute of Energy Systems, TU Dortmund University, Dortmund, Germany","institution_ids":["https://openalex.org/I200332995"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5049645907","display_name":"Jiayan Liu","orcid":"https://orcid.org/0000-0003-2798-8795"},"institutions":[{"id":"https://openalex.org/I200332995","display_name":"TU Dortmund University","ror":"https://ror.org/01k97gp34","country_code":"DE","type":"education","lineage":["https://openalex.org/I200332995"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Jiayan Liu","raw_affiliation_strings":["Energy Efficiency and Energy Economics (ie3), Institute of Energy Systems, TU Dortmund University, Dortmund, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Energy Efficiency and Energy Economics (ie3), Institute of Energy Systems, TU Dortmund University, Dortmund, Germany","institution_ids":["https://openalex.org/I200332995"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5028841407","display_name":"Christian Rehtanz","orcid":"https://orcid.org/0000-0002-8134-6841"},"institutions":[{"id":"https://openalex.org/I200332995","display_name":"TU Dortmund University","ror":"https://ror.org/01k97gp34","country_code":"DE","type":"education","lineage":["https://openalex.org/I200332995"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Christian Rehtanz","raw_affiliation_strings":["Energy Efficiency and Energy Economics (ie3), Institute of Energy Systems, TU Dortmund University, Dortmund, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Energy Efficiency and Energy Economics (ie3), Institute of Energy Systems, TU Dortmund University, Dortmund, Germany","institution_ids":["https://openalex.org/I200332995"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I200332995"],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":"3","issue":null,"first_page":"2203","last_page":"2208"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9925000071525574,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.6700700521469116},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.6420397758483887},{"id":"https://openalex.org/keywords/voltage-source","display_name":"Voltage source","score":0.6246761679649353},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.5691282749176025},{"id":"https://openalex.org/keywords/high-voltage-direct-current","display_name":"High-voltage direct current","score":0.5429264903068542},{"id":"https://openalex.org/keywords/matlab","display_name":"MATLAB","score":0.49900269508361816},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.49746301770210266},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4829546809196472},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4732939600944519},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.4638184905052185},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3474047780036926},{"id":"https://openalex.org/keywords/direct-current","display_name":"Direct current","score":0.34282395243644714},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.18925359845161438},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.16213038563728333}],"concepts":[{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6700700521469116},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.6420397758483887},{"id":"https://openalex.org/C144655898","wikidata":"https://www.wikidata.org/wiki/Q1161128","display_name":"Voltage source","level":3,"score":0.6246761679649353},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5691282749176025},{"id":"https://openalex.org/C2781163877","wikidata":"https://www.wikidata.org/wiki/Q370607","display_name":"High-voltage direct current","level":4,"score":0.5429264903068542},{"id":"https://openalex.org/C2780365114","wikidata":"https://www.wikidata.org/wiki/Q169478","display_name":"MATLAB","level":2,"score":0.49900269508361816},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.49746301770210266},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4829546809196472},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4732939600944519},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.4638184905052185},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3474047780036926},{"id":"https://openalex.org/C2776620479","wikidata":"https://www.wikidata.org/wiki/Q159241","display_name":"Direct current","level":3,"score":0.34282395243644714},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.18925359845161438},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.16213038563728333},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon.2019.8927519","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2019.8927519","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2019 - 45th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.7200000286102295,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W269896242","https://openalex.org/W1571403844","https://openalex.org/W1944055092","https://openalex.org/W2019173942","https://openalex.org/W2021061580","https://openalex.org/W2049620886","https://openalex.org/W2060132056","https://openalex.org/W2106424475","https://openalex.org/W2191912174","https://openalex.org/W2265248459","https://openalex.org/W2498616961","https://openalex.org/W2554675575","https://openalex.org/W6609879538","https://openalex.org/W6687509953"],"related_works":["https://openalex.org/W2357541103","https://openalex.org/W2392523380","https://openalex.org/W4231416742","https://openalex.org/W1998367034","https://openalex.org/W3097649839","https://openalex.org/W2350392996","https://openalex.org/W4363675847","https://openalex.org/W2525907476","https://openalex.org/W2645006444","https://openalex.org/W2549149355"],"abstract_inverted_index":{"This":[0],"paper":[1],"proposes":[2],"an":[3],"optimal":[4,28],"power":[5,30,83],"setting":[6,78],"method":[7,148],"for":[8,67],"voltage-source":[9],"converter":[10],"(VSC)":[11],"based":[12],"high":[13],"voltage":[14,44],"direct":[15],"current":[16],"(HVDC)":[17],"system,":[18,125],"which":[19,126],"enables":[20],"the":[21,33,37,43,47,54,58,64,88,92,102,143,146,151,155,159],"VSC-HVDC":[22],"system":[23,131],"to":[24,31,106,141],"dynamically":[25,86],"select":[26],"its":[27],"injected":[29,82],"reduce":[32],"overall":[34,160],"loading":[35],"of":[36,69,80,145,154],"hybrid":[38,129],"ac/dc":[39,130],"systems.":[40],"Based":[41],"on":[42],"angle":[45],"controller,":[46],"gain":[48,89],"parameter":[49],"K":[50,90],"is":[51,61,84,98,127],"taken":[52,62],"as":[53,63],"decision":[55],"variable":[56],"and":[57,73,137,149],"severity":[59],"index":[60],"objective":[65],"function":[66],"optimization":[68],"different":[70,74],"N-1":[71],"contingencies":[72],"load":[75,103],"scenarios.":[76],"The":[77,114],"value":[79],"HVDC":[81],"adjusted":[85],"through":[87],"in":[91,101,112,120,133,157],"proposed":[93,147],"control":[94],"algorithm":[95],"if":[96],"there":[97],"a":[99,107,110,121,128],"change":[100,111],"flow":[104],"due":[105],"contingency":[108],"or":[109],"demand.":[113],"simulation":[115],"has":[116],"been":[117],"carried":[118],"out":[119],"modified":[122],"IEEE":[123],"39-bus":[124],"built":[132],"MATLAB.":[134],"Simulation":[135],"analysis":[136],"evaluation":[138],"are":[139],"performed":[140],"validate":[142],"effectiveness":[144],"demonstrate":[150],"good":[152],"performance":[153],"strategy":[156],"alleviating":[158],"overload.":[161]},"counts_by_year":[{"year":2020,"cited_by_count":1}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
