{"id":"https://openalex.org/W2996363891","doi":"https://doi.org/10.1109/iecon.2019.8927490","title":"A Study on Shunt Resistor-based Current Measurements for Fast Switching GaN Devices","display_name":"A Study on Shunt Resistor-based Current Measurements for Fast Switching GaN Devices","publication_year":2019,"publication_date":"2019-10-01","ids":{"openalex":"https://openalex.org/W2996363891","doi":"https://doi.org/10.1109/iecon.2019.8927490","mag":"2996363891"},"language":"en","primary_location":{"id":"doi:10.1109/iecon.2019.8927490","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2019.8927490","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2019 - 45th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5089185462","display_name":"Thilini Wickramasinghe","orcid":null},"institutions":[{"id":"https://openalex.org/I100532134","display_name":"Universit\u00e9 Claude Bernard Lyon 1","ror":"https://ror.org/029brtt94","country_code":"FR","type":"education","lineage":["https://openalex.org/I100532134","https://openalex.org/I203339264"]},{"id":"https://openalex.org/I1294671590","display_name":"Centre National de la Recherche Scientifique","ror":"https://ror.org/02feahw73","country_code":"FR","type":"government","lineage":["https://openalex.org/I1294671590"]},{"id":"https://openalex.org/I4210145913","display_name":"Laboratoire Amp\u00e8re","ror":"https://ror.org/04xbczw40","country_code":"FR","type":"facility","lineage":["https://openalex.org/I100532134","https://openalex.org/I112936343","https://openalex.org/I1294671590","https://openalex.org/I203339264","https://openalex.org/I203339264","https://openalex.org/I203339264","https://openalex.org/I4210145913","https://openalex.org/I48430043"]},{"id":"https://openalex.org/I48430043","display_name":"Institut National des Sciences Appliqu\u00e9es de Lyon","ror":"https://ror.org/050jn9y42","country_code":"FR","type":"education","lineage":["https://openalex.org/I203339264","https://openalex.org/I48430043"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Thilini Wickramasinghe","raw_affiliation_strings":["INSA Lyon, CNRS, Ampere, Univ Lyon, Universite Claude Bernard Lyon 1, Villeurbanne, France","EE - Amp\u00e8re, D\u00e9partement Energie Electrique (France)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"INSA Lyon, CNRS, Ampere, Univ Lyon, Universite Claude Bernard Lyon 1, Villeurbanne, France","institution_ids":["https://openalex.org/I4210145913","https://openalex.org/I48430043","https://openalex.org/I100532134","https://openalex.org/I1294671590"]},{"raw_affiliation_string":"EE - Amp\u00e8re, D\u00e9partement Energie Electrique (France)","institution_ids":["https://openalex.org/I4210145913"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5061628796","display_name":"St\u00e9phane Azzopardi","orcid":null},"institutions":[{"id":"https://openalex.org/I4210130984","display_name":"Safran Electronics (Canada)","ror":"https://ror.org/03vmatd47","country_code":"CA","type":"company","lineage":["https://openalex.org/I4210130984"]},{"id":"https://openalex.org/I4210165303","display_name":"Safran (France)","ror":"https://ror.org/05sqf9v67","country_code":"FR","type":"company","lineage":["https://openalex.org/I4210165303"]}],"countries":["CA","FR"],"is_corresponding":false,"raw_author_name":"Stephane Azzopardi","raw_affiliation_strings":["Electrical & Electronics Division, Safran Tech, Safran Paris Saclay, France","Safran Tech (France)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical & Electronics Division, Safran Tech, Safran Paris Saclay, France","institution_ids":["https://openalex.org/I4210165303","https://openalex.org/I4210130984"]},{"raw_affiliation_string":"Safran Tech (France)","institution_ids":["https://openalex.org/I4210165303"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5011435361","display_name":"Bruno Allard","orcid":"https://orcid.org/0000-0001-8547-5483"},"institutions":[{"id":"https://openalex.org/I100532134","display_name":"Universit\u00e9 Claude Bernard Lyon 1","ror":"https://ror.org/029brtt94","country_code":"FR","type":"education","lineage":["https://openalex.org/I100532134","https://openalex.org/I203339264"]},{"id":"https://openalex.org/I1294671590","display_name":"Centre National de la Recherche Scientifique","ror":"https://ror.org/02feahw73","country_code":"FR","type":"government","lineage":["https://openalex.org/I1294671590"]},{"id":"https://openalex.org/I4210145913","display_name":"Laboratoire Amp\u00e8re","ror":"https://ror.org/04xbczw40","country_code":"FR","type":"facility","lineage":["https://openalex.org/I100532134","https://openalex.org/I112936343","https://openalex.org/I1294671590","https://openalex.org/I203339264","https://openalex.org/I203339264","https://openalex.org/I203339264","https://openalex.org/I4210145913","https://openalex.org/I48430043"]},{"id":"https://openalex.org/I48430043","display_name":"Institut National des Sciences Appliqu\u00e9es de Lyon","ror":"https://ror.org/050jn9y42","country_code":"FR","type":"education","lineage":["https://openalex.org/I203339264","https://openalex.org/I48430043"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Bruno Allard","raw_affiliation_strings":["INSA Lyon, CNRS, Ampere, Univ Lyon, Universite Claude Bernard Lyon 1, Villeurbanne, France","EE - Amp\u00e8re, D\u00e9partement Energie Electrique (France)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"INSA Lyon, CNRS, Ampere, Univ Lyon, Universite Claude Bernard Lyon 1, Villeurbanne, France","institution_ids":["https://openalex.org/I4210145913","https://openalex.org/I48430043","https://openalex.org/I100532134","https://openalex.org/I1294671590"]},{"raw_affiliation_string":"EE - Amp\u00e8re, D\u00e9partement Energie Electrique (France)","institution_ids":["https://openalex.org/I4210145913"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5000833132","display_name":"Cyril Buttay","orcid":"https://orcid.org/0000-0001-7140-5804"},"institutions":[{"id":"https://openalex.org/I100532134","display_name":"Universit\u00e9 Claude Bernard Lyon 1","ror":"https://ror.org/029brtt94","country_code":"FR","type":"education","lineage":["https://openalex.org/I100532134","https://openalex.org/I203339264"]},{"id":"https://openalex.org/I1294671590","display_name":"Centre National de la Recherche Scientifique","ror":"https://ror.org/02feahw73","country_code":"FR","type":"government","lineage":["https://openalex.org/I1294671590"]},{"id":"https://openalex.org/I4210145913","display_name":"Laboratoire Amp\u00e8re","ror":"https://ror.org/04xbczw40","country_code":"FR","type":"facility","lineage":["https://openalex.org/I100532134","https://openalex.org/I112936343","https://openalex.org/I1294671590","https://openalex.org/I203339264","https://openalex.org/I203339264","https://openalex.org/I203339264","https://openalex.org/I4210145913","https://openalex.org/I48430043"]},{"id":"https://openalex.org/I48430043","display_name":"Institut National des Sciences Appliqu\u00e9es de Lyon","ror":"https://ror.org/050jn9y42","country_code":"FR","type":"education","lineage":["https://openalex.org/I203339264","https://openalex.org/I48430043"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Cyril Buttay","raw_affiliation_strings":["INSA Lyon, CNRS, Ampere, Univ Lyon, Universite Claude Bernard Lyon 1, Villeurbanne, France","EE - Amp\u00e8re, D\u00e9partement Energie Electrique (France)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"INSA Lyon, CNRS, Ampere, Univ Lyon, Universite Claude Bernard Lyon 1, Villeurbanne, France","institution_ids":["https://openalex.org/I4210145913","https://openalex.org/I48430043","https://openalex.org/I100532134","https://openalex.org/I1294671590"]},{"raw_affiliation_string":"EE - Amp\u00e8re, D\u00e9partement Energie Electrique (France)","institution_ids":["https://openalex.org/I4210145913"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5107881715","display_name":"Charles Joubert","orcid":null},"institutions":[{"id":"https://openalex.org/I100532134","display_name":"Universit\u00e9 Claude Bernard Lyon 1","ror":"https://ror.org/029brtt94","country_code":"FR","type":"education","lineage":["https://openalex.org/I100532134","https://openalex.org/I203339264"]},{"id":"https://openalex.org/I1294671590","display_name":"Centre National de la Recherche Scientifique","ror":"https://ror.org/02feahw73","country_code":"FR","type":"government","lineage":["https://openalex.org/I1294671590"]},{"id":"https://openalex.org/I4210145913","display_name":"Laboratoire Amp\u00e8re","ror":"https://ror.org/04xbczw40","country_code":"FR","type":"facility","lineage":["https://openalex.org/I100532134","https://openalex.org/I112936343","https://openalex.org/I1294671590","https://openalex.org/I203339264","https://openalex.org/I203339264","https://openalex.org/I203339264","https://openalex.org/I4210145913","https://openalex.org/I48430043"]},{"id":"https://openalex.org/I48430043","display_name":"Institut National des Sciences Appliqu\u00e9es de Lyon","ror":"https://ror.org/050jn9y42","country_code":"FR","type":"education","lineage":["https://openalex.org/I203339264","https://openalex.org/I48430043"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Charles Joubert","raw_affiliation_strings":["INSA Lyon, CNRS, Ampere, Univ Lyon, Universite Claude Bernard Lyon 1, Villeurbanne, France","EE - Amp\u00e8re, D\u00e9partement Energie Electrique (France)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"INSA Lyon, CNRS, Ampere, Univ Lyon, Universite Claude Bernard Lyon 1, Villeurbanne, France","institution_ids":["https://openalex.org/I4210145913","https://openalex.org/I48430043","https://openalex.org/I100532134","https://openalex.org/I1294671590"]},{"raw_affiliation_string":"EE - Amp\u00e8re, D\u00e9partement Energie Electrique (France)","institution_ids":["https://openalex.org/I4210145913"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5006090173","display_name":"Christian Martin","orcid":"https://orcid.org/0000-0003-2325-7047"},"institutions":[{"id":"https://openalex.org/I100532134","display_name":"Universit\u00e9 Claude Bernard Lyon 1","ror":"https://ror.org/029brtt94","country_code":"FR","type":"education","lineage":["https://openalex.org/I100532134","https://openalex.org/I203339264"]},{"id":"https://openalex.org/I1294671590","display_name":"Centre National de la Recherche Scientifique","ror":"https://ror.org/02feahw73","country_code":"FR","type":"government","lineage":["https://openalex.org/I1294671590"]},{"id":"https://openalex.org/I4210145913","display_name":"Laboratoire Amp\u00e8re","ror":"https://ror.org/04xbczw40","country_code":"FR","type":"facility","lineage":["https://openalex.org/I100532134","https://openalex.org/I112936343","https://openalex.org/I1294671590","https://openalex.org/I203339264","https://openalex.org/I203339264","https://openalex.org/I203339264","https://openalex.org/I4210145913","https://openalex.org/I48430043"]},{"id":"https://openalex.org/I48430043","display_name":"Institut National des Sciences Appliqu\u00e9es de Lyon","ror":"https://ror.org/050jn9y42","country_code":"FR","type":"education","lineage":["https://openalex.org/I203339264","https://openalex.org/I48430043"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Christian Martin","raw_affiliation_strings":["INSA Lyon, CNRS, Ampere, Univ Lyon, Universite Claude Bernard Lyon 1, Villeurbanne, France","EE - Amp\u00e8re, D\u00e9partement Energie Electrique (France)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"INSA Lyon, CNRS, Ampere, Univ Lyon, Universite Claude Bernard Lyon 1, Villeurbanne, France","institution_ids":["https://openalex.org/I4210145913","https://openalex.org/I48430043","https://openalex.org/I100532134","https://openalex.org/I1294671590"]},{"raw_affiliation_string":"EE - Amp\u00e8re, D\u00e9partement Energie Electrique (France)","institution_ids":["https://openalex.org/I4210145913"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5110941041","display_name":"J. F. Mogniotte","orcid":null},"institutions":[{"id":"https://openalex.org/I100532134","display_name":"Universit\u00e9 Claude Bernard Lyon 1","ror":"https://ror.org/029brtt94","country_code":"FR","type":"education","lineage":["https://openalex.org/I100532134","https://openalex.org/I203339264"]},{"id":"https://openalex.org/I1294671590","display_name":"Centre National de la Recherche Scientifique","ror":"https://ror.org/02feahw73","country_code":"FR","type":"government","lineage":["https://openalex.org/I1294671590"]},{"id":"https://openalex.org/I4210145913","display_name":"Laboratoire Amp\u00e8re","ror":"https://ror.org/04xbczw40","country_code":"FR","type":"facility","lineage":["https://openalex.org/I100532134","https://openalex.org/I112936343","https://openalex.org/I1294671590","https://openalex.org/I203339264","https://openalex.org/I203339264","https://openalex.org/I203339264","https://openalex.org/I4210145913","https://openalex.org/I48430043"]},{"id":"https://openalex.org/I48430043","display_name":"Institut National des Sciences Appliqu\u00e9es de Lyon","ror":"https://ror.org/050jn9y42","country_code":"FR","type":"education","lineage":["https://openalex.org/I203339264","https://openalex.org/I48430043"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Jean-Fracois Mogniotte","raw_affiliation_strings":["INSA Lyon, CNRS, Ampere, Univ Lyon, Universite Claude Bernard Lyon 1, Villeurbanne, France","EE - Amp\u00e8re, D\u00e9partement Energie Electrique (France)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"INSA Lyon, CNRS, Ampere, Univ Lyon, Universite Claude Bernard Lyon 1, Villeurbanne, France","institution_ids":["https://openalex.org/I4210145913","https://openalex.org/I48430043","https://openalex.org/I100532134","https://openalex.org/I1294671590"]},{"raw_affiliation_string":"EE - Amp\u00e8re, D\u00e9partement Energie Electrique (France)","institution_ids":["https://openalex.org/I4210145913"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5047640045","display_name":"Herv\u00e9 Morel","orcid":"https://orcid.org/0000-0001-7866-0437"},"institutions":[{"id":"https://openalex.org/I100532134","display_name":"Universit\u00e9 Claude Bernard Lyon 1","ror":"https://ror.org/029brtt94","country_code":"FR","type":"education","lineage":["https://openalex.org/I100532134","https://openalex.org/I203339264"]},{"id":"https://openalex.org/I1294671590","display_name":"Centre National de la Recherche Scientifique","ror":"https://ror.org/02feahw73","country_code":"FR","type":"government","lineage":["https://openalex.org/I1294671590"]},{"id":"https://openalex.org/I4210145913","display_name":"Laboratoire Amp\u00e8re","ror":"https://ror.org/04xbczw40","country_code":"FR","type":"facility","lineage":["https://openalex.org/I100532134","https://openalex.org/I112936343","https://openalex.org/I1294671590","https://openalex.org/I203339264","https://openalex.org/I203339264","https://openalex.org/I203339264","https://openalex.org/I4210145913","https://openalex.org/I48430043"]},{"id":"https://openalex.org/I48430043","display_name":"Institut National des Sciences Appliqu\u00e9es de Lyon","ror":"https://ror.org/050jn9y42","country_code":"FR","type":"education","lineage":["https://openalex.org/I203339264","https://openalex.org/I48430043"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Herve Morel","raw_affiliation_strings":["INSA Lyon, CNRS, Ampere, Univ Lyon, Universite Claude Bernard Lyon 1, Villeurbanne, France","EE - Amp\u00e8re, D\u00e9partement Energie Electrique (France)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"INSA Lyon, CNRS, Ampere, Univ Lyon, Universite Claude Bernard Lyon 1, Villeurbanne, France","institution_ids":["https://openalex.org/I4210145913","https://openalex.org/I48430043","https://openalex.org/I100532134","https://openalex.org/I1294671590"]},{"raw_affiliation_string":"EE - Amp\u00e8re, D\u00e9partement Energie Electrique (France)","institution_ids":["https://openalex.org/I4210145913"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5036460598","display_name":"Pascal Bevilacqua","orcid":null},"institutions":[{"id":"https://openalex.org/I100532134","display_name":"Universit\u00e9 Claude Bernard Lyon 1","ror":"https://ror.org/029brtt94","country_code":"FR","type":"education","lineage":["https://openalex.org/I100532134","https://openalex.org/I203339264"]},{"id":"https://openalex.org/I1294671590","display_name":"Centre National de la Recherche Scientifique","ror":"https://ror.org/02feahw73","country_code":"FR","type":"government","lineage":["https://openalex.org/I1294671590"]},{"id":"https://openalex.org/I4210145913","display_name":"Laboratoire Amp\u00e8re","ror":"https://ror.org/04xbczw40","country_code":"FR","type":"facility","lineage":["https://openalex.org/I100532134","https://openalex.org/I112936343","https://openalex.org/I1294671590","https://openalex.org/I203339264","https://openalex.org/I203339264","https://openalex.org/I203339264","https://openalex.org/I4210145913","https://openalex.org/I48430043"]},{"id":"https://openalex.org/I48430043","display_name":"Institut National des Sciences Appliqu\u00e9es de Lyon","ror":"https://ror.org/050jn9y42","country_code":"FR","type":"education","lineage":["https://openalex.org/I203339264","https://openalex.org/I48430043"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Pascal Bevilacqua","raw_affiliation_strings":["INSA Lyon, CNRS, Ampere, Univ Lyon, Universite Claude Bernard Lyon 1, Villeurbanne, France","EE - Amp\u00e8re, D\u00e9partement Energie Electrique (France)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"INSA Lyon, CNRS, Ampere, Univ Lyon, Universite Claude Bernard Lyon 1, Villeurbanne, France","institution_ids":["https://openalex.org/I4210145913","https://openalex.org/I48430043","https://openalex.org/I100532134","https://openalex.org/I1294671590"]},{"raw_affiliation_string":"EE - Amp\u00e8re, D\u00e9partement Energie Electrique (France)","institution_ids":["https://openalex.org/I4210145913"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5055796542","display_name":"Thanh-Long Le","orcid":"https://orcid.org/0000-0001-5238-4171"},"institutions":[{"id":"https://openalex.org/I4210130984","display_name":"Safran Electronics (Canada)","ror":"https://ror.org/03vmatd47","country_code":"CA","type":"company","lineage":["https://openalex.org/I4210130984"]},{"id":"https://openalex.org/I4210165303","display_name":"Safran (France)","ror":"https://ror.org/05sqf9v67","country_code":"FR","type":"company","lineage":["https://openalex.org/I4210165303"]}],"countries":["CA","FR"],"is_corresponding":false,"raw_author_name":"Thanh-Long Le","raw_affiliation_strings":["Electrical & Electronics Division, Safran Tech, Safran Paris Saclay, France","Safran Tech (France)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical & Electronics Division, Safran Tech, Safran Paris Saclay, France","institution_ids":["https://openalex.org/I4210165303","https://openalex.org/I4210130984"]},{"raw_affiliation_string":"Safran Tech (France)","institution_ids":["https://openalex.org/I4210165303"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":10,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.7265,"has_fulltext":true,"cited_by_count":13,"citation_normalized_percentile":{"value":0.72961668,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12692","display_name":"Magnetic Field Sensors Techniques","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12692","display_name":"Magnetic Field Sensors Techniques","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12564","display_name":"Sensor Technology and Measurement Systems","score":0.9976999759674072,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10781","display_name":"Plasma Diagnostics and Applications","score":0.9976000189781189,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/resistor","display_name":"Resistor","score":0.7546237707138062},{"id":"https://openalex.org/keywords/waveform","display_name":"Waveform","score":0.6240575313568115},{"id":"https://openalex.org/keywords/shunt","display_name":"Shunt (medical)","score":0.5643226504325867},{"id":"https://openalex.org/keywords/current","display_name":"Current (fluid)","score":0.5575684309005737},{"id":"https://openalex.org/keywords/transistor","display_name":"Transistor","score":0.5034500956535339},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.5006167888641357},{"id":"https://openalex.org/keywords/high-electron-mobility-transistor","display_name":"High-electron-mobility transistor","score":0.49705269932746887},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4534199833869934},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.40382376313209534},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.39941924810409546},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.23423880338668823},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2169918715953827}],"concepts":[{"id":"https://openalex.org/C137488568","wikidata":"https://www.wikidata.org/wiki/Q5321","display_name":"Resistor","level":3,"score":0.7546237707138062},{"id":"https://openalex.org/C197424946","wikidata":"https://www.wikidata.org/wiki/Q1165717","display_name":"Waveform","level":3,"score":0.6240575313568115},{"id":"https://openalex.org/C2780968331","wikidata":"https://www.wikidata.org/wiki/Q1890115","display_name":"Shunt (medical)","level":2,"score":0.5643226504325867},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.5575684309005737},{"id":"https://openalex.org/C172385210","wikidata":"https://www.wikidata.org/wiki/Q5339","display_name":"Transistor","level":3,"score":0.5034500956535339},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.5006167888641357},{"id":"https://openalex.org/C162057924","wikidata":"https://www.wikidata.org/wiki/Q1617706","display_name":"High-electron-mobility transistor","level":4,"score":0.49705269932746887},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4534199833869934},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.40382376313209534},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.39941924810409546},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.23423880338668823},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2169918715953827},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0},{"id":"https://openalex.org/C164705383","wikidata":"https://www.wikidata.org/wiki/Q10379","display_name":"Cardiology","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/iecon.2019.8927490","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2019.8927490","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2019 - 45th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},{"id":"pmh:oai:HAL:hal-02405883v1","is_oa":false,"landing_page_url":"https://hal.science/hal-02405883","pdf_url":null,"source":{"id":"https://openalex.org/S4306402512","display_name":"HAL (Le Centre pour la Communication Scientifique Directe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1294671590","host_organization_name":"Centre National de la Recherche Scientifique","host_organization_lineage":["https://openalex.org/I1294671590"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"45th IEEE IECON, Oct 2019, Lisbonne, Portugal. &#x27E8;10.1109/IECON.2019.8927490&#x27E9;","raw_type":"Conference papers"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.8600000143051147}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W1493080152","https://openalex.org/W1760711217","https://openalex.org/W1898699350","https://openalex.org/W2127394451","https://openalex.org/W2139356817","https://openalex.org/W2430786427","https://openalex.org/W2558945094","https://openalex.org/W6629555573","https://openalex.org/W6637858921","https://openalex.org/W6729858065"],"related_works":["https://openalex.org/W3200817179","https://openalex.org/W1960166976","https://openalex.org/W2532810475","https://openalex.org/W1992708211","https://openalex.org/W2380067098","https://openalex.org/W1548152478","https://openalex.org/W4390729576","https://openalex.org/W2137172615","https://openalex.org/W1986136028","https://openalex.org/W1943995216"],"abstract_inverted_index":{"Current":[0],"viewing":[1],"resistor":[2],"(CVR)":[3],"based":[4],"measurement":[5,129],"of":[6,17,35,42,58,80,87],"a":[7,31,39,91,94],"high":[8],"frequency":[9,29],"switching":[10,28],"cell":[11],"is":[12,122],"presented.":[13],"The":[14,55],"drain":[15],"current":[16,34,118],"the":[18,47,59,65,72,78,84,109,117],"low-side":[19],"GaN":[20],"HEMT":[21],"switch":[22],"was":[23],"measured":[24],"at":[25],"100":[26],"kHz":[27],"for":[30],"maximum":[32],"load":[33],"8":[36],"A":[37],"and":[38,51],"dc":[40],"input":[41],"80":[43],"V.":[44],"To":[45],"analyze":[46],"results,":[48],"both":[49],"simulations":[50],"experiments":[52],"were":[53,69],"used.":[54],"parasitic":[56],"elements":[57],"PCB":[60],"layout":[61],"(i.e.":[62],"calculated":[63],"using":[64],"Ansys-Q3D":[66],"Extractor":[67],"software)":[68],"included":[70],"in":[71,83,102],"simulation":[73,110],"model.":[74],"This":[75],"paper":[76],"explains":[77],"consequences":[79],"mounting":[81],"CVRs":[82],"common-source":[85],"path":[86],"transistors":[88],"compared":[89],"to":[90,100,115,125,127],"circuit":[92],"without":[93],"CVR.":[95],"Simulation":[96],"results":[97],"are":[98],"found":[99],"be":[101,113],"very":[103],"good":[104],"agreement":[105],"with":[106],"measurements.":[107],"Hence,":[108],"model":[111],"can":[112],"used":[114],"estimate":[116],"waveforms":[119],"when":[120],"it":[121],"not":[123],"desirable":[124],"resort":[126],"intrusive":[128],"methods.":[130]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":4},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
