{"id":"https://openalex.org/W2996612056","doi":"https://doi.org/10.1109/iecon.2019.8927310","title":"Soft Switching Full-Bridge Isolated Circuit Solution for Auxiliary Power Supply in Power Converter Systems","display_name":"Soft Switching Full-Bridge Isolated Circuit Solution for Auxiliary Power Supply in Power Converter Systems","publication_year":2019,"publication_date":"2019-10-01","ids":{"openalex":"https://openalex.org/W2996612056","doi":"https://doi.org/10.1109/iecon.2019.8927310","mag":"2996612056"},"language":"en","primary_location":{"id":"doi:10.1109/iecon.2019.8927310","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2019.8927310","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2019 - 45th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5009721837","display_name":"Salvatore Musumeci","orcid":"https://orcid.org/0000-0002-6541-1375"},"institutions":[{"id":"https://openalex.org/I177477856","display_name":"Polytechnic University of Turin","ror":"https://ror.org/00bgk9508","country_code":"IT","type":"education","lineage":["https://openalex.org/I177477856"]}],"countries":["IT"],"is_corresponding":true,"raw_author_name":"Salvatore Musumeci","raw_affiliation_strings":["DENERG - Politecnico di Torino Corso Duca degli Abruzzi 24, Torino, Italy"],"affiliations":[{"raw_affiliation_string":"DENERG - Politecnico di Torino Corso Duca degli Abruzzi 24, Torino, Italy","institution_ids":["https://openalex.org/I177477856"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5031330807","display_name":"Antonino Fratta","orcid":null},"institutions":[{"id":"https://openalex.org/I177477856","display_name":"Polytechnic University of Turin","ror":"https://ror.org/00bgk9508","country_code":"IT","type":"education","lineage":["https://openalex.org/I177477856"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Antonino Fratta","raw_affiliation_strings":["DENERG - Politecnico di Torino Corso Duca degli Abruzzi 24, Torino, Italy"],"affiliations":[{"raw_affiliation_string":"DENERG - Politecnico di Torino Corso Duca degli Abruzzi 24, Torino, Italy","institution_ids":["https://openalex.org/I177477856"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5045235719","display_name":"Eric Armando","orcid":"https://orcid.org/0000-0002-9406-3613"},"institutions":[{"id":"https://openalex.org/I177477856","display_name":"Polytechnic University of Turin","ror":"https://ror.org/00bgk9508","country_code":"IT","type":"education","lineage":["https://openalex.org/I177477856"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Eric Armando","raw_affiliation_strings":["DENERG - Politecnico di Torino Corso Duca degli Abruzzi 24, Torino, Italy"],"affiliations":[{"raw_affiliation_string":"DENERG - Politecnico di Torino Corso Duca degli Abruzzi 24, Torino, Italy","institution_ids":["https://openalex.org/I177477856"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5044502337","display_name":"Fabio Mandrile","orcid":"https://orcid.org/0000-0002-7769-8078"},"institutions":[{"id":"https://openalex.org/I177477856","display_name":"Polytechnic University of Turin","ror":"https://ror.org/00bgk9508","country_code":"IT","type":"education","lineage":["https://openalex.org/I177477856"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Fabio Mandrile","raw_affiliation_strings":["DENERG - Politecnico di Torino Corso Duca degli Abruzzi 24, Torino, Italy"],"affiliations":[{"raw_affiliation_string":"DENERG - Politecnico di Torino Corso Duca degli Abruzzi 24, Torino, Italy","institution_ids":["https://openalex.org/I177477856"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5026157412","display_name":"Stefano Borlo","orcid":"https://orcid.org/0000-0002-1027-9629"},"institutions":[{"id":"https://openalex.org/I177477856","display_name":"Polytechnic University of Turin","ror":"https://ror.org/00bgk9508","country_code":"IT","type":"education","lineage":["https://openalex.org/I177477856"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Stefano Borlo","raw_affiliation_strings":["DENERG - Politecnico di Torino Corso Duca degli Abruzzi 24, Torino, Italy"],"affiliations":[{"raw_affiliation_string":"DENERG - Politecnico di Torino Corso Duca degli Abruzzi 24, Torino, Italy","institution_ids":["https://openalex.org/I177477856"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5009721837"],"corresponding_institution_ids":["https://openalex.org/I177477856"],"apc_list":null,"apc_paid":null,"fwci":0.2385,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.57103086,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":96},"biblio":{"volume":"18","issue":null,"first_page":"1985","last_page":"1990"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11444","display_name":"Electromagnetic Compatibility and Noise Suppression","score":0.9987000226974487,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9979000091552734,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/switched-mode-power-supply","display_name":"Switched-mode power supply","score":0.5934919118881226},{"id":"https://openalex.org/keywords/galvanic-isolation","display_name":"Galvanic isolation","score":0.5601600408554077},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.5594752430915833},{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.5490737557411194},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.5096979141235352},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.4763612747192383},{"id":"https://openalex.org/keywords/electronic-circuit","display_name":"Electronic circuit","score":0.4722185432910919},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.44790834188461304},{"id":"https://openalex.org/keywords/emi","display_name":"EMI","score":0.4400048851966858},{"id":"https://openalex.org/keywords/isolation-transformer","display_name":"Isolation transformer","score":0.41860058903694153},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3831009268760681},{"id":"https://openalex.org/keywords/electromagnetic-interference","display_name":"Electromagnetic interference","score":0.33454635739326477},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.15980756282806396}],"concepts":[{"id":"https://openalex.org/C151799858","wikidata":"https://www.wikidata.org/wiki/Q587008","display_name":"Switched-mode power supply","level":3,"score":0.5934919118881226},{"id":"https://openalex.org/C70234604","wikidata":"https://www.wikidata.org/wiki/Q780813","display_name":"Galvanic isolation","level":4,"score":0.5601600408554077},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5594752430915833},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.5490737557411194},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.5096979141235352},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.4763612747192383},{"id":"https://openalex.org/C134146338","wikidata":"https://www.wikidata.org/wiki/Q1815901","display_name":"Electronic circuit","level":2,"score":0.4722185432910919},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.44790834188461304},{"id":"https://openalex.org/C43461449","wikidata":"https://www.wikidata.org/wiki/Q2495531","display_name":"EMI","level":3,"score":0.4400048851966858},{"id":"https://openalex.org/C180850520","wikidata":"https://www.wikidata.org/wiki/Q2166404","display_name":"Isolation transformer","level":4,"score":0.41860058903694153},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3831009268760681},{"id":"https://openalex.org/C184892835","wikidata":"https://www.wikidata.org/wiki/Q1474513","display_name":"Electromagnetic interference","level":2,"score":0.33454635739326477},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.15980756282806396}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon.2019.8927310","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2019.8927310","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2019 - 45th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8999999761581421,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":15,"referenced_works":["https://openalex.org/W1484118206","https://openalex.org/W1489769401","https://openalex.org/W1503801110","https://openalex.org/W1969215641","https://openalex.org/W2039914397","https://openalex.org/W2040375951","https://openalex.org/W2059876098","https://openalex.org/W2136609174","https://openalex.org/W2164509356","https://openalex.org/W2169282325","https://openalex.org/W2171213417","https://openalex.org/W2397013629","https://openalex.org/W2571324454","https://openalex.org/W2587779081","https://openalex.org/W2781281175"],"related_works":["https://openalex.org/W76001227","https://openalex.org/W2349537384","https://openalex.org/W1986241886","https://openalex.org/W2041511579","https://openalex.org/W3120066331","https://openalex.org/W2549052135","https://openalex.org/W4385545073","https://openalex.org/W1921091955","https://openalex.org/W2101259838","https://openalex.org/W2375350703"],"abstract_inverted_index":{"This":[0],"paper":[1],"deals":[2],"with":[3,90,134],"an":[4,83,91],"isolated":[5],"full-bridge":[6],"circuit":[7,21,67,97,105],"designed":[8],"to":[9,60,80],"distribute":[10],"the":[11,30,34,50,56,66,99,102],"auxiliary":[12],"power":[13,17,38,75,112],"supplies":[14],"needed":[15],"in":[16,33,110],"converters.":[18],"The":[19,25,104],"proposed":[20],"features":[22],"soft-switching":[23],"operation.":[24],"provided":[26],"galvanic":[27],"isolation":[28],"limits":[29],"disturbances":[31],"propagation":[32],"critical":[35],"circuits":[36],"of":[37,52,101],"converters,":[39],"such":[40,114],"as":[41,115],"gate":[42],"drivers":[43],"and":[44,54,94,118],"control":[45],"circuits.":[46],"Soft":[47],"switching":[48],"allows":[49],"reduction":[51],"EMI":[53],"increases":[55],"converter":[57,64],"efficiency.":[58,136],"Compared":[59],"a":[61,71,88,95],"classic":[62],"flyback":[63],"solution,":[65],"is":[68],"based":[69],"on":[70],"high":[72],"frequency":[73],"AC":[74],"distribution.":[76],"In":[77],"every":[78],"point":[79],"be":[81],"supplied,":[82],"additional":[84],"transformer":[85],"followed":[86],"by":[87],"rectifier":[89],"output":[92],"filter":[93],"regulator":[96],"satisfy":[98],"requests":[100],"load.":[103],"has":[106],"been":[107],"widely":[108],"applied":[109],"various":[111],"converters":[113,122],"inverters,":[116],"PFCs":[117],"DC-DC":[119],"full":[120],"bridge":[121],"for":[123],"battery":[124],"chargers,":[125],"showing":[126],"insulation":[127],"benefits,":[128],"noise":[129],"rejection":[130],"characteristics,":[131],"improved":[132],"reliability":[133],"adequate":[135]},"counts_by_year":[{"year":2022,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
