{"id":"https://openalex.org/W2995059472","doi":"https://doi.org/10.1109/iecon.2019.8927043","title":"Analysis of DC-link Current of Parallel Three-phase Inverters under Unbalanced Output Currents","display_name":"Analysis of DC-link Current of Parallel Three-phase Inverters under Unbalanced Output Currents","publication_year":2019,"publication_date":"2019-10-01","ids":{"openalex":"https://openalex.org/W2995059472","doi":"https://doi.org/10.1109/iecon.2019.8927043","mag":"2995059472"},"language":"en","primary_location":{"id":"doi:10.1109/iecon.2019.8927043","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2019.8927043","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2019 - 45th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101405854","display_name":"Wu Liang","orcid":"https://orcid.org/0000-0003-2568-5301"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Liang Wu","raw_affiliation_strings":["College of Electrical Engineering, Zhejiang University,Hangzhou,China","College of Electrical Engineering, Zhejiang University, Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"College of Electrical Engineering, Zhejiang University,Hangzhou,China","institution_ids":["https://openalex.org/I76130692"]},{"raw_affiliation_string":"College of Electrical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5076107801","display_name":"Hongyi Lin","orcid":"https://orcid.org/0000-0002-4710-4195"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Hongyi Lin","raw_affiliation_strings":["College of Electrical Engineering, Zhejiang University,Hangzhou,China","College of Electrical Engineering, Zhejiang University, Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"College of Electrical Engineering, Zhejiang University,Hangzhou,China","institution_ids":["https://openalex.org/I76130692"]},{"raw_affiliation_string":"College of Electrical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100765831","display_name":"Linhai Zhao","orcid":"https://orcid.org/0000-0003-1935-635X"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Linhai Zhao","raw_affiliation_strings":["College of Electrical Engineering, Zhejiang University,Hangzhou,China","College of Electrical Engineering, Zhejiang University, Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"College of Electrical Engineering, Zhejiang University,Hangzhou,China","institution_ids":["https://openalex.org/I76130692"]},{"raw_affiliation_string":"College of Electrical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5101634073","display_name":"Guozhu Chen","orcid":"https://orcid.org/0000-0002-4565-090X"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Guozhu Chen","raw_affiliation_strings":["College of Electrical Engineering, Zhejiang University,Hangzhou,China","College of Electrical Engineering, Zhejiang University, Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"College of Electrical Engineering, Zhejiang University,Hangzhou,China","institution_ids":["https://openalex.org/I76130692"]},{"raw_affiliation_string":"College of Electrical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5101405854"],"corresponding_institution_ids":["https://openalex.org/I76130692"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.13964141,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"3381","last_page":"3386"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.996399998664856,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/interleaving","display_name":"Interleaving","score":0.5963493585586548},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.5694047212600708},{"id":"https://openalex.org/keywords/pulse-width-modulation","display_name":"Pulse-width modulation","score":0.5426521897315979},{"id":"https://openalex.org/keywords/inverter","display_name":"Inverter","score":0.5352848768234253},{"id":"https://openalex.org/keywords/three-phase","display_name":"Three-phase","score":0.5315423011779785},{"id":"https://openalex.org/keywords/current","display_name":"Current (fluid)","score":0.5116375088691711},{"id":"https://openalex.org/keywords/harmonics","display_name":"Harmonics","score":0.47649234533309937},{"id":"https://openalex.org/keywords/harmonic-analysis","display_name":"Harmonic analysis","score":0.4605926275253296},{"id":"https://openalex.org/keywords/capacitor","display_name":"Capacitor","score":0.4431026577949524},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.43997880816459656},{"id":"https://openalex.org/keywords/harmonic","display_name":"Harmonic","score":0.4321352243423462},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.4209126830101013},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.39791831374168396},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.3296835720539093},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2942579686641693},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.2776780128479004},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.20328554511070251},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.06915491819381714}],"concepts":[{"id":"https://openalex.org/C28034677","wikidata":"https://www.wikidata.org/wiki/Q17092530","display_name":"Interleaving","level":2,"score":0.5963493585586548},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.5694047212600708},{"id":"https://openalex.org/C92746544","wikidata":"https://www.wikidata.org/wiki/Q585184","display_name":"Pulse-width modulation","level":3,"score":0.5426521897315979},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.5352848768234253},{"id":"https://openalex.org/C173871940","wikidata":"https://www.wikidata.org/wiki/Q471846","display_name":"Three-phase","level":3,"score":0.5315423011779785},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.5116375088691711},{"id":"https://openalex.org/C188414643","wikidata":"https://www.wikidata.org/wiki/Q3001183","display_name":"Harmonics","level":3,"score":0.47649234533309937},{"id":"https://openalex.org/C131770355","wikidata":"https://www.wikidata.org/wiki/Q876215","display_name":"Harmonic analysis","level":2,"score":0.4605926275253296},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.4431026577949524},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.43997880816459656},{"id":"https://openalex.org/C127934551","wikidata":"https://www.wikidata.org/wiki/Q1148098","display_name":"Harmonic","level":2,"score":0.4321352243423462},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4209126830101013},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.39791831374168396},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3296835720539093},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2942579686641693},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2776780128479004},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.20328554511070251},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.06915491819381714},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon.2019.8927043","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2019.8927043","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2019 - 45th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":19,"referenced_works":["https://openalex.org/W50271627","https://openalex.org/W2001784669","https://openalex.org/W2084118989","https://openalex.org/W2106049364","https://openalex.org/W2121658281","https://openalex.org/W2137717497","https://openalex.org/W2138273601","https://openalex.org/W2139083250","https://openalex.org/W2141718171","https://openalex.org/W2158186496","https://openalex.org/W2535286314","https://openalex.org/W2548065050","https://openalex.org/W2549057131","https://openalex.org/W2742674329","https://openalex.org/W2754377806","https://openalex.org/W2768725817","https://openalex.org/W2770571418","https://openalex.org/W2907897449","https://openalex.org/W3141456309"],"related_works":["https://openalex.org/W2026048727","https://openalex.org/W2525517395","https://openalex.org/W2162458593","https://openalex.org/W2031753233","https://openalex.org/W2543604558","https://openalex.org/W2143833827","https://openalex.org/W3041419339","https://openalex.org/W2536922071","https://openalex.org/W2125960862","https://openalex.org/W1970875790"],"abstract_inverted_index":{"Analysis":[0],"and":[1,23,58,78,90,121,131],"calculation":[2,79,132],"of":[3,6,11,14,17,26,47,80,110,133,146],"DC-link":[4,32,117],"current":[5,33,66,83,118,136],"three-phase":[7,39,85,101],"inverter":[8,86],"is":[9,119,126,137],"one":[10],"significant":[12],"part":[13],"the":[15,24,53,59,76,81,91,108,122,129,134,143,147],"selection":[16],"dc":[18,106],"capacitors,":[19],"system":[20],"life":[21],"expectation":[22],"stability":[25],"converter":[27],"control.":[28],"However,":[29],"almost":[30],"all":[31],"analysis":[34,77,130,148],"have":[35],"focused":[36],"on":[37,116],"balanced":[38],"ac":[40],"output":[41,65,74,152],"currents":[42],"so":[43],"far.":[44],"For":[45],"applications":[46],"four-wire":[48],"power":[49,55],"quality":[50],"improvement,":[51],"like":[52],"active":[54],"filter":[56],"(APF)":[57],"static":[60],"VAR":[61],"generator":[62],"(SVG),":[63],"unbalanced":[64,73,151],"are":[67,87,95],"required.":[68],"In":[69],"this":[70],"paper,":[71],"considering":[72],"currents,":[75],"dc-link":[82,135],"for":[84,99],"firstly":[88],"presented":[89],"sideband":[92],"harmonic":[93],"orders":[94],"derived":[96],"subsequently.":[97],"Then,":[98],"parallel":[100],"inverters":[102],"with":[103],"a":[104],"shared":[105],"bus,":[107],"effect":[109],"interleaved":[111],"carrier":[112],"phase":[113],"shift":[114],"PWM":[115],"studied":[120],"optimal":[123],"interleaving":[124],"angle":[125],"derived.":[127],"Finally,":[128],"verified":[138],"by":[139],"simulation,":[140],"which":[141],"shows":[142],"good":[144],"accuracy":[145],"results":[149],"under":[150],"currents.":[153]},"counts_by_year":[{"year":2024,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
