{"id":"https://openalex.org/W2994834581","doi":"https://doi.org/10.1109/iecon.2019.8926843","title":"TAB Based Multiport Converter with Optimized Transformer RMS Current and Improved ZVS Range for DC Microgrid Applications","display_name":"TAB Based Multiport Converter with Optimized Transformer RMS Current and Improved ZVS Range for DC Microgrid Applications","publication_year":2019,"publication_date":"2019-10-01","ids":{"openalex":"https://openalex.org/W2994834581","doi":"https://doi.org/10.1109/iecon.2019.8926843","mag":"2994834581"},"language":"en","primary_location":{"id":"doi:10.1109/iecon.2019.8926843","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2019.8926843","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2019 - 45th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5075079616","display_name":"Ishita Biswas","orcid":"https://orcid.org/0000-0002-4175-455X"},"institutions":[{"id":"https://openalex.org/I145894827","display_name":"Indian Institute of Technology Kharagpur","ror":"https://ror.org/03w5sq511","country_code":"IN","type":"education","lineage":["https://openalex.org/I145894827"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Ishita Biswas","raw_affiliation_strings":["Department of Electrical Engineering, Indian Institute of Technology Kharagpur, West Bengal, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Indian Institute of Technology Kharagpur, West Bengal, India","institution_ids":["https://openalex.org/I145894827"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5005753456","display_name":"Debaprasad Kastha","orcid":"https://orcid.org/0000-0001-6276-1022"},"institutions":[{"id":"https://openalex.org/I145894827","display_name":"Indian Institute of Technology Kharagpur","ror":"https://ror.org/03w5sq511","country_code":"IN","type":"education","lineage":["https://openalex.org/I145894827"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Debaprasad Kastha","raw_affiliation_strings":["Department of Electrical Engineering, Indian Institute of Technology Kharagpur, West Bengal, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Indian Institute of Technology Kharagpur, West Bengal, India","institution_ids":["https://openalex.org/I145894827"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5087124286","display_name":"Prabodh Bajpai","orcid":"https://orcid.org/0000-0003-4262-9213"},"institutions":[{"id":"https://openalex.org/I145894827","display_name":"Indian Institute of Technology Kharagpur","ror":"https://ror.org/03w5sq511","country_code":"IN","type":"education","lineage":["https://openalex.org/I145894827"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Prabodh Bajpai","raw_affiliation_strings":["Department of Electrical Engineering, Indian Institute of Technology Kharagpur, West Bengal, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Indian Institute of Technology Kharagpur, West Bengal, India","institution_ids":["https://openalex.org/I145894827"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.6055,"has_fulltext":false,"cited_by_count":9,"citation_normalized_percentile":{"value":0.70267461,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":"23","issue":null,"first_page":"2050","last_page":"2055"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.6832735538482666},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.6285899877548218},{"id":"https://openalex.org/keywords/duty-cycle","display_name":"Duty cycle","score":0.6180402636528015},{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.5866454243659973},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.5457288026809692},{"id":"https://openalex.org/keywords/forward-converter","display_name":"Forward converter","score":0.49650079011917114},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.47824564576148987},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.45807382464408875},{"id":"https://openalex.org/keywords/flyback-converter","display_name":"Flyback converter","score":0.4325410723686218},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.43170490860939026},{"id":"https://openalex.org/keywords/half-bridge","display_name":"Half bridge","score":0.41986560821533203},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3618204891681671},{"id":"https://openalex.org/keywords/boost-converter","display_name":"Boost converter","score":0.355889230966568},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.3131239414215088},{"id":"https://openalex.org/keywords/capacitor","display_name":"Capacitor","score":0.2073739469051361},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.07948845624923706}],"concepts":[{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.6832735538482666},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.6285899877548218},{"id":"https://openalex.org/C199822604","wikidata":"https://www.wikidata.org/wiki/Q557120","display_name":"Duty cycle","level":3,"score":0.6180402636528015},{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.5866454243659973},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.5457288026809692},{"id":"https://openalex.org/C55118286","wikidata":"https://www.wikidata.org/wiki/Q634739","display_name":"Forward converter","level":4,"score":0.49650079011917114},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.47824564576148987},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.45807382464408875},{"id":"https://openalex.org/C103303742","wikidata":"https://www.wikidata.org/wiki/Q1293595","display_name":"Flyback converter","level":4,"score":0.4325410723686218},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.43170490860939026},{"id":"https://openalex.org/C3019968007","wikidata":"https://www.wikidata.org/wiki/Q5641793","display_name":"Half bridge","level":4,"score":0.41986560821533203},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3618204891681671},{"id":"https://openalex.org/C78336795","wikidata":"https://www.wikidata.org/wiki/Q760134","display_name":"Boost converter","level":3,"score":0.355889230966568},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3131239414215088},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.2073739469051361},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.07948845624923706},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon.2019.8926843","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2019.8926843","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2019 - 45th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.8600000143051147,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W1963575896","https://openalex.org/W2041150481","https://openalex.org/W2060382072","https://openalex.org/W2117616877","https://openalex.org/W2129374939","https://openalex.org/W2154853703","https://openalex.org/W2221532817","https://openalex.org/W2343916353","https://openalex.org/W2404933504","https://openalex.org/W2562778755","https://openalex.org/W2591673579","https://openalex.org/W2607079595","https://openalex.org/W2612150755","https://openalex.org/W2742851395","https://openalex.org/W2800033826","https://openalex.org/W2897270735"],"related_works":["https://openalex.org/W1539693063","https://openalex.org/W2972794140","https://openalex.org/W2501890988","https://openalex.org/W3214460120","https://openalex.org/W2024567372","https://openalex.org/W2162727408","https://openalex.org/W2013624817","https://openalex.org/W2540337461","https://openalex.org/W2539781515","https://openalex.org/W2981438596"],"abstract_inverted_index":{"In":[0],"this":[1],"paper,":[2],"a":[3],"current":[4,76],"fed":[5],"triple":[6],"active":[7],"bridge":[8],"(TAB)":[9],"based":[10],"multiport":[11],"converter":[12],"(MPC)":[13],"for":[14],"DC":[15],"mircrogrid":[16],"(DCMG)":[17],"application":[18],"is":[19,38,69,86,109],"analyzed":[20],"considering":[21],"full":[22],"range":[23,100],"variation":[24],"of":[25,101,107],"the":[26,44,73,90,97,102,113],"input":[27],"voltage":[28,80,92],"and":[29,77,117],"load":[30],"power.":[31],"A":[32,63,83,104],"generalized":[33],"frequency":[34],"domain":[35],"modeling":[36,48],"approach":[37,49],"proposed":[39,70,114],"in":[40],"order":[41,55],"to":[42,53,71,88,111],"reduce":[43],"design":[45],"complexity.":[46],"This":[47],"can":[50],"be":[51],"extended":[52],"higher":[54],"MPCs":[56],"with":[57],"`n'":[58],"winding":[59],"transformer":[60,74],"coupled":[61],"converters.":[62],"modified":[64],"duty":[65],"ratio":[66],"control":[67],"scheme":[68],"minimize":[72],"rms":[75],"extend":[78],"zero":[79,91],"switching":[81,93],"range.":[82],"detailed":[84],"analysis":[85],"performed":[87],"identify":[89],"(ZVS)":[94],"region":[95],"over":[96],"whole":[98],"operating":[99],"converter.":[103],"laboratory":[105],"prototype":[106],"2kW":[108],"built":[110],"verify":[112],"modulation":[115],"strategy":[116],"theoretical":[118],"analysis.":[119]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":4},{"year":2020,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
