{"id":"https://openalex.org/W2908362311","doi":"https://doi.org/10.1109/iecon.2018.8591988","title":"A Hybrid FACTS Topology for Reactive Power Support in High Voltage Transmission Systems","display_name":"A Hybrid FACTS Topology for Reactive Power Support in High Voltage Transmission Systems","publication_year":2018,"publication_date":"2018-10-01","ids":{"openalex":"https://openalex.org/W2908362311","doi":"https://doi.org/10.1109/iecon.2018.8591988","mag":"2908362311"},"language":"en","primary_location":{"id":"doi:10.1109/iecon.2018.8591988","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2018.8591988","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2018 - 44th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5047914848","display_name":"Chandrasekhar Roy","orcid":"https://orcid.org/0000-0003-4984-168X"},"institutions":[{"id":"https://openalex.org/I145894827","display_name":"Indian Institute of Technology Kharagpur","ror":"https://ror.org/03w5sq511","country_code":"IN","type":"education","lineage":["https://openalex.org/I145894827"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"Chandrasekhar Roy","raw_affiliation_strings":["Department of Electrical Engineering, Indian Institute of Technology, Kharagpur, India"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Indian Institute of Technology, Kharagpur, India","institution_ids":["https://openalex.org/I145894827"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5049915218","display_name":"Dheeman Chatterjee","orcid":"https://orcid.org/0000-0002-1994-4592"},"institutions":[{"id":"https://openalex.org/I145894827","display_name":"Indian Institute of Technology Kharagpur","ror":"https://ror.org/03w5sq511","country_code":"IN","type":"education","lineage":["https://openalex.org/I145894827"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Dheeman Chatterjee","raw_affiliation_strings":["Department of Electrical Engineering, Indian Institute of Technology, Kharagpur, India"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Indian Institute of Technology, Kharagpur, India","institution_ids":["https://openalex.org/I145894827"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5019143608","display_name":"Tanmoy Bhattarcharya","orcid":null},"institutions":[{"id":"https://openalex.org/I145894827","display_name":"Indian Institute of Technology Kharagpur","ror":"https://ror.org/03w5sq511","country_code":"IN","type":"education","lineage":["https://openalex.org/I145894827"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Tanmoy Bhattarcharya","raw_affiliation_strings":["Department of Electrical Engineering, Indian Institute of Technology, Kharagpur, India"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Indian Institute of Technology, Kharagpur, India","institution_ids":["https://openalex.org/I145894827"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5047914848"],"corresponding_institution_ids":["https://openalex.org/I145894827"],"apc_list":null,"apc_paid":null,"fwci":0.9013,"has_fulltext":false,"cited_by_count":9,"citation_normalized_percentile":{"value":0.77005484,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":"3","issue":null,"first_page":"65","last_page":"70"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12277","display_name":"Frequency Control in Power Systems","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/topology","display_name":"Topology (electrical circuits)","score":0.6352736949920654},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.5948312282562256},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.5263691544532776},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.523515522480011},{"id":"https://openalex.org/keywords/transmission","display_name":"Transmission (telecommunications)","score":0.4565126895904541},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.42575234174728394},{"id":"https://openalex.org/keywords/power-transmission","display_name":"Power transmission","score":0.41199198365211487},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3702091574668884},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.3318740129470825},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.21457532048225403},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.1962900161743164},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.14618197083473206}],"concepts":[{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.6352736949920654},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.5948312282562256},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5263691544532776},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.523515522480011},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.4565126895904541},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.42575234174728394},{"id":"https://openalex.org/C92018576","wikidata":"https://www.wikidata.org/wiki/Q3242194","display_name":"Power transmission","level":3,"score":0.41199198365211487},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3702091574668884},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3318740129470825},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.21457532048225403},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.1962900161743164},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.14618197083473206},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon.2018.8591988","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2018.8591988","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2018 - 44th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.8399999737739563,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W2059437797","https://openalex.org/W2129167801","https://openalex.org/W2154980236","https://openalex.org/W2161888380","https://openalex.org/W2163039626","https://openalex.org/W2243748485","https://openalex.org/W2534266921","https://openalex.org/W2540876324","https://openalex.org/W2625571500","https://openalex.org/W6739480208"],"related_works":["https://openalex.org/W2382154054","https://openalex.org/W2391476397","https://openalex.org/W4243932773","https://openalex.org/W2386726014","https://openalex.org/W2614109884","https://openalex.org/W2037662127","https://openalex.org/W2788046494","https://openalex.org/W2389452010","https://openalex.org/W2154276918","https://openalex.org/W1977014720"],"abstract_inverted_index":{"This":[0],"paper":[1],"proposes":[2],"a":[3,13,52,60,117,138,144],"hybrid":[4,70,132],"FACTS":[5],"topology":[6,133],"for":[7,97,109,121,149],"constant":[8,139],"reactive":[9,140],"current":[10,141],"support,":[11],"within":[12],"reasonable":[14],"range":[15],"of":[16,51,79,100,112,130,155],"power":[17],"system":[18],"voltage,":[19],"in":[20,42,46,57,74,123],"high":[21,26,39],"voltage":[22,27,44],"(HV)":[23],"and":[24,104,125],"extra":[25],"(EHV)":[28],"transmission":[29],"systems.":[30,48,127],"The":[31,69,128],"configuration":[32,71],"is":[33,72,89,95,107,147],"an":[34],"economical":[35],"solution":[36,120],"to":[37,76,136],"the":[38,77,93,101,105,110,113,131,151,156],"cost":[40,119],"involved":[41],"providing":[43,116],"support":[45],"HV":[47,124],"It":[49],"consists":[50],"Static":[53],"VAr":[54],"compensator":[55,63],"(SVC)":[56],"series":[58],"with":[59,65],"static":[61],"synchronous":[62],"(STATCOM)":[64],"significantly":[66],"lower":[67,118],"rating.":[68],"put":[73],"shunt":[75],"point":[78],"common":[80],"coupling":[81],"(PCC).":[82],"A":[83],"vector":[84],"control":[85,87,129,145],"based":[86],"strategy":[88,146],"proposed,":[90],"such":[91],"that":[92],"STATCOM":[94],"rated":[96,108],"just":[98],"15%":[99],"total":[102],"compensation":[103],"SVC":[106],"rest":[111],"85%,":[114],"thus":[115],"applications":[122],"EHV":[126],"enables":[134],"it":[135],"provide":[137],"support.":[142],"Also":[143],"proposed":[148],"balancing":[150],"isolated":[152],"dc-link":[153],"voltages":[154],"parallel":[157],"connected":[158],"inverters.":[159]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":6},{"year":2020,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
