{"id":"https://openalex.org/W2904068173","doi":"https://doi.org/10.1109/iecon.2018.8591661","title":"Permanent Magnet Synchronous Machines Inter- Turn Short Circuit Fault Detection by Means of Model-Based Residual Analysis","display_name":"Permanent Magnet Synchronous Machines Inter- Turn Short Circuit Fault Detection by Means of Model-Based Residual Analysis","publication_year":2018,"publication_date":"2018-10-01","ids":{"openalex":"https://openalex.org/W2904068173","doi":"https://doi.org/10.1109/iecon.2018.8591661","mag":"2904068173"},"language":"en","primary_location":{"id":"doi:10.1109/iecon.2018.8591661","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2018.8591661","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2018 - 44th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5018331643","display_name":"Fernando Alvarez\u2010Gonzalez","orcid":"https://orcid.org/0000-0003-4854-1853"},"institutions":[{"id":"https://openalex.org/I91136226","display_name":"University of Sheffield","ror":"https://ror.org/05krs5044","country_code":"GB","type":"education","lineage":["https://openalex.org/I91136226"]}],"countries":["GB"],"is_corresponding":true,"raw_author_name":"Fernando Alvarez-Gonzalez","raw_affiliation_strings":["Department of Electronic and Electrical Engineering, University of Sheffield, Sheffield, UK"],"affiliations":[{"raw_affiliation_string":"Department of Electronic and Electrical Engineering, University of Sheffield, Sheffield, UK","institution_ids":["https://openalex.org/I91136226"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5057615108","display_name":"Antonio Griffo","orcid":"https://orcid.org/0000-0001-5642-2921"},"institutions":[{"id":"https://openalex.org/I91136226","display_name":"University of Sheffield","ror":"https://ror.org/05krs5044","country_code":"GB","type":"education","lineage":["https://openalex.org/I91136226"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Antonio Griffo","raw_affiliation_strings":["Department of Electronic and Electrical Engineering, University of Sheffield, Sheffield, UK"],"affiliations":[{"raw_affiliation_string":"Department of Electronic and Electrical Engineering, University of Sheffield, Sheffield, UK","institution_ids":["https://openalex.org/I91136226"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100407984","display_name":"Bo Wang","orcid":"https://orcid.org/0000-0001-5951-0089"},"institutions":[{"id":"https://openalex.org/I91136226","display_name":"University of Sheffield","ror":"https://ror.org/05krs5044","country_code":"GB","type":"education","lineage":["https://openalex.org/I91136226"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Bo Wang","raw_affiliation_strings":["Department of Electronic and Electrical Engineering, University of Sheffield, Sheffield, UK"],"affiliations":[{"raw_affiliation_string":"Department of Electronic and Electrical Engineering, University of Sheffield, Sheffield, UK","institution_ids":["https://openalex.org/I91136226"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5018331643"],"corresponding_institution_ids":["https://openalex.org/I91136226"],"apc_list":null,"apc_paid":null,"fwci":0.5617,"has_fulltext":false,"cited_by_count":16,"citation_normalized_percentile":{"value":0.69444398,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":98},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.9962000250816345,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10504","display_name":"Sensorless Control of Electric Motors","score":0.9847000241279602,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.7504144906997681},{"id":"https://openalex.org/keywords/residual","display_name":"Residual","score":0.7457448244094849},{"id":"https://openalex.org/keywords/stator","display_name":"Stator","score":0.7273569107055664},{"id":"https://openalex.org/keywords/harmonics","display_name":"Harmonics","score":0.6776621341705322},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5234886407852173},{"id":"https://openalex.org/keywords/harmonic-analysis","display_name":"Harmonic analysis","score":0.5170732140541077},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.510008692741394},{"id":"https://openalex.org/keywords/magnet","display_name":"Magnet","score":0.5017349720001221},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.5012176036834717},{"id":"https://openalex.org/keywords/finite-element-method","display_name":"Finite element method","score":0.4957621991634369},{"id":"https://openalex.org/keywords/synchronous-motor","display_name":"Synchronous motor","score":0.4922856390476227},{"id":"https://openalex.org/keywords/transient","display_name":"Transient (computer programming)","score":0.4674929678440094},{"id":"https://openalex.org/keywords/stuck-at-fault","display_name":"Stuck-at fault","score":0.4159137010574341},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.36184337735176086},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.34725451469421387},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.2683678865432739},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.18072474002838135},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.11211881041526794},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.09686994552612305},{"id":"https://openalex.org/keywords/structural-engineering","display_name":"Structural engineering","score":0.06638342142105103},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.06368988752365112}],"concepts":[{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.7504144906997681},{"id":"https://openalex.org/C155512373","wikidata":"https://www.wikidata.org/wiki/Q287450","display_name":"Residual","level":2,"score":0.7457448244094849},{"id":"https://openalex.org/C2776529397","wikidata":"https://www.wikidata.org/wiki/Q190312","display_name":"Stator","level":2,"score":0.7273569107055664},{"id":"https://openalex.org/C188414643","wikidata":"https://www.wikidata.org/wiki/Q3001183","display_name":"Harmonics","level":3,"score":0.6776621341705322},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5234886407852173},{"id":"https://openalex.org/C131770355","wikidata":"https://www.wikidata.org/wiki/Q876215","display_name":"Harmonic analysis","level":2,"score":0.5170732140541077},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.510008692741394},{"id":"https://openalex.org/C16389437","wikidata":"https://www.wikidata.org/wiki/Q11421","display_name":"Magnet","level":2,"score":0.5017349720001221},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5012176036834717},{"id":"https://openalex.org/C135628077","wikidata":"https://www.wikidata.org/wiki/Q220184","display_name":"Finite element method","level":2,"score":0.4957621991634369},{"id":"https://openalex.org/C71376005","wikidata":"https://www.wikidata.org/wiki/Q845675","display_name":"Synchronous motor","level":2,"score":0.4922856390476227},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.4674929678440094},{"id":"https://openalex.org/C13625343","wikidata":"https://www.wikidata.org/wiki/Q7627418","display_name":"Stuck-at fault","level":4,"score":0.4159137010574341},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.36184337735176086},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.34725451469421387},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.2683678865432739},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.18072474002838135},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.11211881041526794},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.09686994552612305},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.06638342142105103},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.06368988752365112},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/iecon.2018.8591661","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2018.8591661","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2018 - 44th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},{"id":"pmh:oai:dsp.tecnalia.com:11556/8028","is_oa":false,"landing_page_url":"https://hdl.handle.net/11556/8028","pdf_url":null,"source":{"id":"https://openalex.org/S4306402037","display_name":"TECNALIA Publications (Fundaci\u00f3n TECNALIA Research & Innovation)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210113430","host_organization_name":"Tecnalia","host_organization_lineage":["https://openalex.org/I4210113430"],"host_organization_lineage_names":[],"type":"repository"},"license":"public-domain","license_id":"https://openalex.org/licenses/public-domain","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"conference output"},{"id":"pmh:oai:eprints.whiterose.ac.uk:139579","is_oa":false,"landing_page_url":"http://eprints.whiterose.ac.uk/139579/","pdf_url":null,"source":{"id":"https://openalex.org/S4306400854","display_name":"White Rose Research Online (University of Leeds, The University of Sheffield, University of York)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I2800616092","host_organization_name":"White Rose University Consortium","host_organization_lineage":["https://openalex.org/I2800616092"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Proceedings Paper"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":27,"referenced_works":["https://openalex.org/W1514928698","https://openalex.org/W1535187300","https://openalex.org/W2003460769","https://openalex.org/W2026550072","https://openalex.org/W2038384654","https://openalex.org/W2061698056","https://openalex.org/W2063829626","https://openalex.org/W2080850924","https://openalex.org/W2098113420","https://openalex.org/W2122214279","https://openalex.org/W2129135438","https://openalex.org/W2136389802","https://openalex.org/W2145223406","https://openalex.org/W2149988524","https://openalex.org/W2158499370","https://openalex.org/W2161167902","https://openalex.org/W2165337740","https://openalex.org/W2168852723","https://openalex.org/W2169582464","https://openalex.org/W2245160967","https://openalex.org/W2293986360","https://openalex.org/W2600040096","https://openalex.org/W2602794282","https://openalex.org/W2610954082","https://openalex.org/W2742768961","https://openalex.org/W2780841638","https://openalex.org/W2783819238"],"related_works":["https://openalex.org/W2109347519","https://openalex.org/W2123933290","https://openalex.org/W2189047639","https://openalex.org/W2113435021","https://openalex.org/W2070470653","https://openalex.org/W1601183655","https://openalex.org/W2543367579","https://openalex.org/W3158101110","https://openalex.org/W2275520905","https://openalex.org/W2904068173"],"abstract_inverted_index":{"Short":[0],"circuit":[1],"faults":[2],"in":[3,12,50,97],"the":[4,44,71,74,77,89],"stator":[5],"winding":[6],"are":[7,48,144],"a":[8,22,64,122,125,133],"common":[9],"failure":[10],"mode":[11],"Permanent":[13],"Magnet":[14],"Synchronous":[15],"Machines":[16],"(PMSM).":[17],"Model-based":[18],"fault":[19,38,55,66],"detection":[20,56,67],"has":[21],"potential":[23],"benefit":[24],"of":[25,43,73,88,121],"being":[26,46],"less":[27],"sensitive":[28],"to":[29,33,52,127],"transient":[30],"conditions":[31],"compared":[32],"frequency-domain":[34],"based":[35,69,96],"methods":[36,140],"for":[37,113],"detection.":[39],"However,":[40],"accurate":[41,54,85],"models":[42],"machine":[45],"monitored":[47],"required":[49],"order":[51],"produce":[53],"whilst":[57],"avoiding":[58],"false":[59],"alarms.":[60],"This":[61],"paper":[62],"presents":[63],"model-based":[65],"method":[68],"on":[70],"analysis":[72,110],"residual":[75,123],"between":[76],"measured":[78],"currents":[79],"and":[80,95,116,141],"those":[81],"predicted":[82],"by":[83,132],"an":[84],"real-time":[86,137],"model":[87,92],"machine.":[90],"The":[91,119],"is":[93],"nonlinear":[94],"pre-calculated":[98],"flux":[99],"linkages":[100],"look":[101],"up":[102],"tables":[103],"obtained":[104],"through":[105],"magneto":[106],"static":[107],"finite":[108],"element":[109],"(FEA),":[111],"accounting":[112],"magnetic":[114],"saturation":[115],"spatial":[117],"harmonics.":[118],"use":[120],"provides":[124],"mean":[126],"amplify":[128],"frequency":[129],"components":[130],"caused":[131],"fault.":[134],"Computer":[135],"simulations,":[136],"Hardware-in-the-Loop":[138],"(HIL)":[139],"experimental":[142],"validations":[143],"provided.":[145]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":5},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":4},{"year":2021,"cited_by_count":2},{"year":2019,"cited_by_count":1}],"updated_date":"2026-04-04T16:13:02.066488","created_date":"2025-10-10T00:00:00"}