{"id":"https://openalex.org/W2908093538","doi":"https://doi.org/10.1109/iecon.2018.8591656","title":"Grid-Interactive Dual-Paralleled Buck/Boost Converter","display_name":"Grid-Interactive Dual-Paralleled Buck/Boost Converter","publication_year":2018,"publication_date":"2018-10-01","ids":{"openalex":"https://openalex.org/W2908093538","doi":"https://doi.org/10.1109/iecon.2018.8591656","mag":"2908093538"},"language":"en","primary_location":{"id":"doi:10.1109/iecon.2018.8591656","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2018.8591656","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2018 - 44th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100429628","display_name":"Liming Liu","orcid":"https://orcid.org/0000-0003-0140-9812"},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Liming Liu","raw_affiliation_strings":["ABB U.S. Corporate Research Center, Raleigh, NC, USA"],"affiliations":[{"raw_affiliation_string":"ABB U.S. Corporate Research Center, Raleigh, NC, USA","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5102151806","display_name":"Jing Xu","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Jing Xu","raw_affiliation_strings":["ABB U.S. Corporate Research Center, Raleigh, NC, USA"],"affiliations":[{"raw_affiliation_string":"ABB U.S. Corporate Research Center, Raleigh, NC, USA","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5014580622","display_name":"Sandeep Bala","orcid":"https://orcid.org/0000-0001-8100-0683"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Sandeep Bala","raw_affiliation_strings":["ABB U.S. Corporate Research Center, Raleigh, NC, USA"],"affiliations":[{"raw_affiliation_string":"ABB U.S. Corporate Research Center, Raleigh, NC, USA","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5010802421","display_name":"Joonas Puukko","orcid":null},"institutions":[{"id":"https://openalex.org/I4210125890","display_name":"ABB (Finland)","ror":"https://ror.org/03faeab35","country_code":"FI","type":"company","lineage":["https://openalex.org/I4210125890","https://openalex.org/I885143765"]}],"countries":["FI"],"is_corresponding":false,"raw_author_name":"Joonas Puukko","raw_affiliation_strings":["ABB Oy, Helsinki, Finland"],"affiliations":[{"raw_affiliation_string":"ABB Oy, Helsinki, Finland","institution_ids":["https://openalex.org/I4210125890"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5100429628"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.1288,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.51439725,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"1243","last_page":"1248"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9983000159263611,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/robustness","display_name":"Robustness (evolution)","score":0.6383261680603027},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6263498067855835},{"id":"https://openalex.org/keywords/buck-converter","display_name":"Buck converter","score":0.5980281829833984},{"id":"https://openalex.org/keywords/buck\u2013boost-converter","display_name":"Buck\u2013boost converter","score":0.5953156352043152},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.5243430733680725},{"id":"https://openalex.org/keywords/inverter","display_name":"Inverter","score":0.5232188701629639},{"id":"https://openalex.org/keywords/boost-converter","display_name":"Boost converter","score":0.519393265247345},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.49330249428749084},{"id":"https://openalex.org/keywords/dual","display_name":"Dual (grammatical number)","score":0.4827393889427185},{"id":"https://openalex.org/keywords/power-flow","display_name":"Power flow","score":0.43540069460868835},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.39786118268966675},{"id":"https://openalex.org/keywords/topology","display_name":"Topology (electrical circuits)","score":0.3410486578941345},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.3375425338745117},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2863278388977051},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.2150949239730835},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.2090764343738556},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.08784836530685425}],"concepts":[{"id":"https://openalex.org/C63479239","wikidata":"https://www.wikidata.org/wiki/Q7353546","display_name":"Robustness (evolution)","level":3,"score":0.6383261680603027},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6263498067855835},{"id":"https://openalex.org/C150818752","wikidata":"https://www.wikidata.org/wiki/Q83804","display_name":"Buck converter","level":3,"score":0.5980281829833984},{"id":"https://openalex.org/C42043438","wikidata":"https://www.wikidata.org/wiki/Q1671740","display_name":"Buck\u2013boost converter","level":4,"score":0.5953156352043152},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5243430733680725},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.5232188701629639},{"id":"https://openalex.org/C78336795","wikidata":"https://www.wikidata.org/wiki/Q760134","display_name":"Boost converter","level":3,"score":0.519393265247345},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.49330249428749084},{"id":"https://openalex.org/C2780980858","wikidata":"https://www.wikidata.org/wiki/Q110022","display_name":"Dual (grammatical number)","level":2,"score":0.4827393889427185},{"id":"https://openalex.org/C2986056383","wikidata":"https://www.wikidata.org/wiki/Q556030","display_name":"Power flow","level":4,"score":0.43540069460868835},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.39786118268966675},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.3410486578941345},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3375425338745117},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2863278388977051},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.2150949239730835},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.2090764343738556},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.08784836530685425},{"id":"https://openalex.org/C142362112","wikidata":"https://www.wikidata.org/wiki/Q735","display_name":"Art","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.0},{"id":"https://openalex.org/C55493867","wikidata":"https://www.wikidata.org/wiki/Q7094","display_name":"Biochemistry","level":1,"score":0.0},{"id":"https://openalex.org/C124952713","wikidata":"https://www.wikidata.org/wiki/Q8242","display_name":"Literature","level":1,"score":0.0},{"id":"https://openalex.org/C104317684","wikidata":"https://www.wikidata.org/wiki/Q7187","display_name":"Gene","level":2,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon.2018.8591656","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2018.8591656","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2018 - 44th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.7400000095367432,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":2,"referenced_works":["https://openalex.org/W2143552116","https://openalex.org/W2167106294"],"related_works":["https://openalex.org/W2169705106","https://openalex.org/W2249417072","https://openalex.org/W4286633625","https://openalex.org/W2134431346","https://openalex.org/W4210485917","https://openalex.org/W2390522420","https://openalex.org/W3023706037","https://openalex.org/W1943439215","https://openalex.org/W2168219526","https://openalex.org/W2029288183"],"abstract_inverted_index":{"This":[0,58],"paper":[1,59],"presents":[2],"a":[3],"grid-interactive":[4],"dual-paralleled":[5],"buck/boost":[6],"converter":[7,66,85],"with":[8,41],"four-quadrant":[9,81],"power":[10,49,53],"flow":[11],"capability.":[12],"The":[13],"primary":[14],"advantage":[15],"of":[16,37,64,83,96],"this":[17,84],"topology":[18],"compared":[19],"to":[20,78,92],"the":[21,35,61,65,71,75,80,94,97],"traditional":[22,38],"H-bridge":[23],"inverter":[24],"is":[25,86],"its":[26],"inherent":[27],"robustness":[28],"against":[29],"shoot-through":[30],"problems.":[31],"Further,":[32],"by":[33],"combining":[34],"use":[36],"Si":[39],"devices":[40],"wide":[42],"bandgap":[43],"devices,":[44],"one":[45],"can":[46],"get":[47],"reduced":[48],"loss":[50],"and":[51,70],"higher":[52],"density":[54],"at":[55],"acceptable":[56],"cost.":[57],"analyzes":[60],"operation":[62,82],"modes":[63],"under":[67],"different":[68],"conditions,":[69],"control":[72],"logic":[73],"for":[74],"active":[76],"switches":[77],"perform":[79],"developed.":[87],"Simulation":[88],"results":[89],"are":[90],"provided":[91],"demonstrate":[93],"viability":[95],"proposed":[98],"approach.":[99]},"counts_by_year":[{"year":2019,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}