{"id":"https://openalex.org/W2773246834","doi":"https://doi.org/10.1109/iecon.2017.8217373","title":"Photovoltaic supplied grid-connected modular multilevel converter with active power injection and reactive power compensation capability","display_name":"Photovoltaic supplied grid-connected modular multilevel converter with active power injection and reactive power compensation capability","publication_year":2017,"publication_date":"2017-10-01","ids":{"openalex":"https://openalex.org/W2773246834","doi":"https://doi.org/10.1109/iecon.2017.8217373","mag":"2773246834"},"language":"en","primary_location":{"id":"doi:10.1109/iecon.2017.8217373","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2017.8217373","pdf_url":null,"source":{"id":"https://openalex.org/S4363608531","display_name":"IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5071371187","display_name":"Ke Shen","orcid":"https://orcid.org/0000-0003-2979-410X"},"institutions":[{"id":"https://openalex.org/I17145004","display_name":"Northwestern Polytechnical University","ror":"https://ror.org/01y0j0j86","country_code":"CN","type":"education","lineage":["https://openalex.org/I17145004"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Ke Shen","raw_affiliation_strings":["School of Automation, Northwestern Polytechnical University, Xi'an, China"],"affiliations":[{"raw_affiliation_string":"School of Automation, Northwestern Polytechnical University, Xi'an, China","institution_ids":["https://openalex.org/I17145004"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5078048156","display_name":"Dan Zhao","orcid":"https://orcid.org/0000-0001-7022-1018"},"institutions":[{"id":"https://openalex.org/I17145004","display_name":"Northwestern Polytechnical University","ror":"https://ror.org/01y0j0j86","country_code":"CN","type":"education","lineage":["https://openalex.org/I17145004"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Dan Zhao","raw_affiliation_strings":["School of Automation, Northwestern Polytechnical University, Xi'an, China"],"affiliations":[{"raw_affiliation_string":"School of Automation, Northwestern Polytechnical University, Xi'an, China","institution_ids":["https://openalex.org/I17145004"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5043965502","display_name":"Guodong Zhao","orcid":"https://orcid.org/0000-0002-9920-8244"},"institutions":[{"id":"https://openalex.org/I17145004","display_name":"Northwestern Polytechnical University","ror":"https://ror.org/01y0j0j86","country_code":"CN","type":"education","lineage":["https://openalex.org/I17145004"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Guodong Zhao","raw_affiliation_strings":["School of Automation, Northwestern Polytechnical University, Xi'an, China"],"affiliations":[{"raw_affiliation_string":"School of Automation, Northwestern Polytechnical University, Xi'an, China","institution_ids":["https://openalex.org/I17145004"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5064645242","display_name":"Shaozhe Wang","orcid":"https://orcid.org/0000-0001-7614-8157"},"institutions":[{"id":"https://openalex.org/I17145004","display_name":"Northwestern Polytechnical University","ror":"https://ror.org/01y0j0j86","country_code":"CN","type":"education","lineage":["https://openalex.org/I17145004"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Shaozhe Wang","raw_affiliation_strings":["School of Automation, Northwestern Polytechnical University, Xi'an, China"],"affiliations":[{"raw_affiliation_string":"School of Automation, Northwestern Polytechnical University, Xi'an, China","institution_ids":["https://openalex.org/I17145004"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5071371187"],"corresponding_institution_ids":["https://openalex.org/I17145004"],"apc_list":null,"apc_paid":null,"fwci":2.5823,"has_fulltext":false,"cited_by_count":15,"citation_normalized_percentile":{"value":0.89366488,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":98},"biblio":{"volume":"22","issue":null,"first_page":"7837","last_page":"7842"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.9908999800682068,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9793999791145325,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.8283495903015137},{"id":"https://openalex.org/keywords/photovoltaic-system","display_name":"Photovoltaic system","score":0.6379035711288452},{"id":"https://openalex.org/keywords/modular-design","display_name":"Modular design","score":0.6378583908081055},{"id":"https://openalex.org/keywords/compensation","display_name":"Compensation (psychology)","score":0.610404908657074},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5351091027259827},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.47941824793815613},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.47622257471084595},{"id":"https://openalex.org/keywords/power-control","display_name":"Power control","score":0.4420086443424225},{"id":"https://openalex.org/keywords/correctness","display_name":"Correctness","score":0.43815356492996216},{"id":"https://openalex.org/keywords/maximum-power-point-tracking","display_name":"Maximum power point tracking","score":0.430327832698822},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4298327565193176},{"id":"https://openalex.org/keywords/inverter","display_name":"Inverter","score":0.3970273435115814},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.39515358209609985},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.3749545216560364},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3252636790275574},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.2898041307926178},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.14608916640281677},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.08344730734825134},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.07402509450912476}],"concepts":[{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.8283495903015137},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.6379035711288452},{"id":"https://openalex.org/C101468663","wikidata":"https://www.wikidata.org/wiki/Q1620158","display_name":"Modular design","level":2,"score":0.6378583908081055},{"id":"https://openalex.org/C2780023022","wikidata":"https://www.wikidata.org/wiki/Q1338171","display_name":"Compensation (psychology)","level":2,"score":0.610404908657074},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5351091027259827},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.47941824793815613},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.47622257471084595},{"id":"https://openalex.org/C56685638","wikidata":"https://www.wikidata.org/wiki/Q2300474","display_name":"Power control","level":3,"score":0.4420086443424225},{"id":"https://openalex.org/C55439883","wikidata":"https://www.wikidata.org/wiki/Q360812","display_name":"Correctness","level":2,"score":0.43815356492996216},{"id":"https://openalex.org/C36139824","wikidata":"https://www.wikidata.org/wiki/Q1052007","display_name":"Maximum power point tracking","level":4,"score":0.430327832698822},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4298327565193176},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.3970273435115814},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.39515358209609985},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3749545216560364},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3252636790275574},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2898041307926178},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.14608916640281677},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.08344730734825134},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.07402509450912476},{"id":"https://openalex.org/C11171543","wikidata":"https://www.wikidata.org/wiki/Q41630","display_name":"Psychoanalysis","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C15744967","wikidata":"https://www.wikidata.org/wiki/Q9418","display_name":"Psychology","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon.2017.8217373","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2017.8217373","pdf_url":null,"source":{"id":"https://openalex.org/S4363608531","display_name":"IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.8399999737739563}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W1932246598","https://openalex.org/W1983673580","https://openalex.org/W2035576976","https://openalex.org/W2039571779","https://openalex.org/W2056370486","https://openalex.org/W2071463580","https://openalex.org/W2086647021","https://openalex.org/W2089803913","https://openalex.org/W2113437530","https://openalex.org/W2131444823","https://openalex.org/W2132232422","https://openalex.org/W2136109242","https://openalex.org/W2157830548","https://openalex.org/W2166946635","https://openalex.org/W2331863386","https://openalex.org/W6659321510"],"related_works":["https://openalex.org/W1667647204","https://openalex.org/W2404647514","https://openalex.org/W4247536566","https://openalex.org/W2018477250","https://openalex.org/W3119814709","https://openalex.org/W4241418540","https://openalex.org/W1508895727","https://openalex.org/W2725786787","https://openalex.org/W1875930651","https://openalex.org/W1590965489"],"abstract_inverted_index":{"This":[0],"paper":[1],"discusses":[2],"the":[3,33,47,76,81],"active":[4,53],"and":[5,56,78],"reactive":[6,37,58],"power":[7,38,54,59],"control":[8,44],"method":[9],"for":[10,32],"a":[11,66],"modular":[12,68],"multilevel":[13,69],"converter":[14],"(MMC)":[15],"based":[16],"grid-connected":[17],"PV":[18,48,70],"system.":[19],"The":[20,41,72],"voltage":[21],"vector":[22],"space":[23],"analysis":[24,35],"is":[25],"performed":[26,64],"by":[27],"using":[28],"average":[29],"value":[30],"models":[31],"feasibility":[34,79],"of":[36,80],"compensation":[39],"(RPC).":[40],"proposed":[42,82],"double-loop":[43],"strategy":[45],"enables":[46],"system":[49],"to":[50],"handle":[51],"unidirectional":[52],"flow":[55],"bidirectional":[57],"flow.":[60],"Experiments":[61],"have":[62],"been":[63],"on":[65],"laboratory-scaled":[67],"inverter.":[71],"experimental":[73],"results":[74],"verify":[75],"correctness":[77],"strategy.":[83]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":2},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":5},{"year":2019,"cited_by_count":4},{"year":2018,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
