{"id":"https://openalex.org/W2771661132","doi":"https://doi.org/10.1109/iecon.2017.8217036","title":"Retiring strategies of transformer LCC with reliability of power transmission system considered","display_name":"Retiring strategies of transformer LCC with reliability of power transmission system considered","publication_year":2017,"publication_date":"2017-10-01","ids":{"openalex":"https://openalex.org/W2771661132","doi":"https://doi.org/10.1109/iecon.2017.8217036","mag":"2771661132"},"language":"en","primary_location":{"id":"doi:10.1109/iecon.2017.8217036","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2017.8217036","pdf_url":null,"source":{"id":"https://openalex.org/S4363608531","display_name":"IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101014481","display_name":"Mingxing Zhu","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Mingxing Zhu","raw_affiliation_strings":["State Grid Bengbu Power Supply Company Bengbu, Bengbu, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Bengbu Power Supply Company Bengbu, Bengbu, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5021808319","display_name":"Liangyan Jia","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Liangyan Jia","raw_affiliation_strings":["State Grid Bengbu Power Supply Company Bengbu, Bengbu, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Bengbu Power Supply Company Bengbu, Bengbu, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5102765314","display_name":"Hao Hu","orcid":"https://orcid.org/0000-0003-1959-6740"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Hao Hu","raw_affiliation_strings":["State Grid Bengbu Power Supply Company Bengbu, Bengbu, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Bengbu Power Supply Company Bengbu, Bengbu, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5001926598","display_name":"Jing Chen","orcid":"https://orcid.org/0000-0001-5615-2255"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Jing Chen","raw_affiliation_strings":["State Grid Bengbu Power Supply Company, Bengbu, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Bengbu Power Supply Company, Bengbu, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5088418889","display_name":"Zhongchao Wu","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Zhongchao Wu","raw_affiliation_strings":["State Grid Bengbu Power Supply Company Bengbu, Bengbu, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Bengbu Power Supply Company Bengbu, Bengbu, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5069029572","display_name":"Dabo Zhang","orcid":"https://orcid.org/0000-0003-2149-6511"},"institutions":[{"id":"https://openalex.org/I16365422","display_name":"Hefei University of Technology","ror":"https://ror.org/02czkny70","country_code":"CN","type":"education","lineage":["https://openalex.org/I16365422"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Dabo Zhang","raw_affiliation_strings":["School of Electric Engineering and Automation, Hefei University of Technology Hefei, Hefei, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Electric Engineering and Automation, Hefei University of Technology Hefei, Hefei, China","institution_ids":["https://openalex.org/I16365422"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5020019416","display_name":"Yigang He","orcid":"https://orcid.org/0000-0002-6642-0740"},"institutions":[{"id":"https://openalex.org/I16365422","display_name":"Hefei University of Technology","ror":"https://ror.org/02czkny70","country_code":"CN","type":"education","lineage":["https://openalex.org/I16365422"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yigang He","raw_affiliation_strings":["School of Electric Engineering and Automation, Hefei University of Technology Hefei, Hefei, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Electric Engineering and Automation, Hefei University of Technology Hefei, Hefei, China","institution_ids":["https://openalex.org/I16365422"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5101889982","display_name":"Hefu Ye","orcid":"https://orcid.org/0000-0002-5927-9574"},"institutions":[{"id":"https://openalex.org/I17442442","display_name":"State Grid Corporation of China (China)","ror":"https://ror.org/05twwhs70","country_code":"CN","type":"company","lineage":["https://openalex.org/I17442442"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Haifeng Ye","raw_affiliation_strings":["State Grid Anhui Electric Power Company Hefei, Hefei, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Anhui Electric Power Company Hefei, Hefei, China","institution_ids":["https://openalex.org/I17442442"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":8,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.27665706,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":"29","issue":null,"first_page":"5974","last_page":"5979"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.998199999332428,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.998199999332428,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.9959999918937683,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12804","display_name":"Thermal Analysis in Power Transmission","score":0.9858999848365784,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.6816698312759399},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.6248800754547119},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.5926718711853027},{"id":"https://openalex.org/keywords/power-transmission","display_name":"Power transmission","score":0.5491882562637329},{"id":"https://openalex.org/keywords/transmission-system","display_name":"Transmission system","score":0.5299181938171387},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.5061103701591492},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.49179962277412415},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.41276824474334717},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.33719927072525024},{"id":"https://openalex.org/keywords/transmission","display_name":"Transmission (telecommunications)","score":0.27917784452438354},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.26492440700531006},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.15282893180847168},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.06899026036262512}],"concepts":[{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.6816698312759399},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.6248800754547119},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.5926718711853027},{"id":"https://openalex.org/C92018576","wikidata":"https://www.wikidata.org/wiki/Q3242194","display_name":"Power transmission","level":3,"score":0.5491882562637329},{"id":"https://openalex.org/C113608303","wikidata":"https://www.wikidata.org/wiki/Q1056835","display_name":"Transmission system","level":3,"score":0.5299181938171387},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5061103701591492},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.49179962277412415},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.41276824474334717},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.33719927072525024},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.27917784452438354},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.26492440700531006},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.15282893180847168},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.06899026036262512},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon.2017.8217036","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2017.8217036","pdf_url":null,"source":{"id":"https://openalex.org/S4363608531","display_name":"IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.5099999904632568,"display_name":"Responsible consumption and production","id":"https://metadata.un.org/sdg/12"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W978173797","https://openalex.org/W1143789725","https://openalex.org/W1577199596","https://openalex.org/W2352502423","https://openalex.org/W2354422038","https://openalex.org/W2360093391","https://openalex.org/W2372702422","https://openalex.org/W2377644968","https://openalex.org/W2389226645","https://openalex.org/W2491712964","https://openalex.org/W2764426559","https://openalex.org/W4206146559","https://openalex.org/W6705897501"],"related_works":["https://openalex.org/W2155742919","https://openalex.org/W1914681266","https://openalex.org/W2047067935","https://openalex.org/W2126772035","https://openalex.org/W4390418672","https://openalex.org/W2391302974","https://openalex.org/W2013107008","https://openalex.org/W2384975577","https://openalex.org/W3135260911","https://openalex.org/W2377726350"],"abstract_inverted_index":{"In":[0],"order":[1],"to":[2,8,84,109,119],"elevate":[3],"equipment-oriented":[4],"traditional":[5],"asset":[6,11],"management":[7,12],"system-oriented":[9],"advanced":[10],"(AAM)":[13],"decision-making":[14],"for":[15,19],"smart":[16],"power":[17,74,99],"grid,":[18],"the":[20,28,139],"problem":[21],"that":[22],"influence":[23],"of":[24,27,44,56,68,73,92,98,122,138,144,152],"different":[25,125],"positions":[26],"equipment":[29],"in":[30,41],"network":[31],"topology":[32],"on":[33],"system":[34,76,101,145,149],"reliability":[35,72,96,143],"is":[36],"not":[37,105],"taken":[38],"into":[39],"consideration":[40],"retiring":[42,66],"strategies":[43,67],"transformer":[45,64,69,93,115],"LCC":[46,70,121],"(life":[47],"cycle":[48],"cost),":[49],"which":[50],"may":[51],"cause":[52],"overestimation":[53],"or":[54,61],"underestimation":[55],"outage":[57,111],"cost":[58,112],"and":[59,89,94,141],"premature":[60],"excessively":[62],"late":[63],"retiring,":[65],"with":[71],"transmission":[75,100],"was":[77,155],"proposed.":[78],"This":[79],"method":[80,133,154],"used":[81,95],"historical":[82],"data":[83],"calculate":[85],"time-varying":[86],"aging":[87],"fault":[88,116],"unavailability":[90],"rate":[91],"index":[97],"-":[102,108],"expected":[103],"energy":[104],"supplied":[106],"(EENS)":[107],"measure":[110],"caused":[113],"by":[114],"so":[117],"as":[118],"obtain":[120],"transformers":[123,140],"at":[124],"topological":[126],"positions.":[127],"Retiring":[128],"time":[129],"obtained":[130],"through":[131],"this":[132,153],"could":[134],"maximize":[135],"economic":[136],"benefit":[137],"guarantee":[142],"operation.":[146],"IEEE-14":[147],"test":[148],"analyzed,":[150],"effectiveness":[151],"verified.":[156]},"counts_by_year":[{"year":2022,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}