{"id":"https://openalex.org/W2775452865","doi":"https://doi.org/10.1109/iecon.2017.8216245","title":"Power flow control of triple active bridge converter equipped with AC/DC converter for constructing autonomous hybrid AC/DC microgrid systems","display_name":"Power flow control of triple active bridge converter equipped with AC/DC converter for constructing autonomous hybrid AC/DC microgrid systems","publication_year":2017,"publication_date":"2017-10-01","ids":{"openalex":"https://openalex.org/W2775452865","doi":"https://doi.org/10.1109/iecon.2017.8216245","mag":"2775452865"},"language":"en","primary_location":{"id":"doi:10.1109/iecon.2017.8216245","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2017.8216245","pdf_url":null,"source":{"id":"https://openalex.org/S4363608531","display_name":"IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5057051928","display_name":"Keigo Katagiri","orcid":null},"institutions":[{"id":"https://openalex.org/I27429435","display_name":"Kyoto Institute of Technology","ror":"https://ror.org/00965ax52","country_code":"JP","type":"education","lineage":["https://openalex.org/I27429435"]}],"countries":["JP"],"is_corresponding":true,"raw_author_name":"Keigo Katagiri","raw_affiliation_strings":["Kyoto Institute of Technology, Kyoto-shi, Kyoto, Japan"],"affiliations":[{"raw_affiliation_string":"Kyoto Institute of Technology, Kyoto-shi, Kyoto, Japan","institution_ids":["https://openalex.org/I27429435"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5040444872","display_name":"Shota Nakagawa","orcid":"https://orcid.org/0000-0003-2700-5584"},"institutions":[{"id":"https://openalex.org/I27429435","display_name":"Kyoto Institute of Technology","ror":"https://ror.org/00965ax52","country_code":"JP","type":"education","lineage":["https://openalex.org/I27429435"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Shota Nakagawa","raw_affiliation_strings":["Kyoto Institute of Technology, Kyoto-shi, Kyoto, Japan"],"affiliations":[{"raw_affiliation_string":"Kyoto Institute of Technology, Kyoto-shi, Kyoto, Japan","institution_ids":["https://openalex.org/I27429435"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5068938176","display_name":"Kento Kurosawa","orcid":null},"institutions":[{"id":"https://openalex.org/I27429435","display_name":"Kyoto Institute of Technology","ror":"https://ror.org/00965ax52","country_code":"JP","type":"education","lineage":["https://openalex.org/I27429435"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Kento Kurosawa","raw_affiliation_strings":["Kyoto Institute of Technology, Kyoto-shi, Kyoto, Japan"],"affiliations":[{"raw_affiliation_string":"Kyoto Institute of Technology, Kyoto-shi, Kyoto, Japan","institution_ids":["https://openalex.org/I27429435"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5004092735","display_name":"Junichi Arai","orcid":"https://orcid.org/0000-0003-0809-5174"},"institutions":[{"id":"https://openalex.org/I27429435","display_name":"Kyoto Institute of Technology","ror":"https://ror.org/00965ax52","country_code":"JP","type":"education","lineage":["https://openalex.org/I27429435"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Junichi Arai","raw_affiliation_strings":["Kyoto Institute of Technology, Kyoto-shi, Kyoto, Japan"],"affiliations":[{"raw_affiliation_string":"Kyoto Institute of Technology, Kyoto-shi, Kyoto, Japan","institution_ids":["https://openalex.org/I27429435"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5050920713","display_name":"Yuichi Kado","orcid":"https://orcid.org/0000-0002-9093-6317"},"institutions":[{"id":"https://openalex.org/I27429435","display_name":"Kyoto Institute of Technology","ror":"https://ror.org/00965ax52","country_code":"JP","type":"education","lineage":["https://openalex.org/I27429435"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Yuichi Kado","raw_affiliation_strings":["Kyoto Institute of Technology, Kyoto-shi, Kyoto, Japan"],"affiliations":[{"raw_affiliation_string":"Kyoto Institute of Technology, Kyoto-shi, Kyoto, Japan","institution_ids":["https://openalex.org/I27429435"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5072376672","display_name":"Keiji W\u00e3da","orcid":"https://orcid.org/0000-0002-8590-8813"},"institutions":[{"id":"https://openalex.org/I69740276","display_name":"Tokyo Metropolitan University","ror":"https://ror.org/00ws30h19","country_code":"JP","type":"education","lineage":["https://openalex.org/I69740276"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Keiji Wada","raw_affiliation_strings":["Tokyo Metropolitan University, Hachioji, Tokyo, Japan"],"affiliations":[{"raw_affiliation_string":"Tokyo Metropolitan University, Hachioji, Tokyo, Japan","institution_ids":["https://openalex.org/I69740276"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":6,"corresponding_author_ids":["https://openalex.org/A5057051928"],"corresponding_institution_ids":["https://openalex.org/I27429435"],"apc_list":null,"apc_paid":null,"fwci":3.0987,"has_fulltext":false,"cited_by_count":8,"citation_normalized_percentile":{"value":0.91978008,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9968000054359436,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.7466837763786316},{"id":"https://openalex.org/keywords/power-flow","display_name":"Power flow","score":0.6125308275222778},{"id":"https://openalex.org/keywords/forward-converter","display_name":"Forward converter","score":0.5988983511924744},{"id":"https://openalex.org/keywords/flyback-converter","display_name":"Flyback converter","score":0.5804927945137024},{"id":"https://openalex.org/keywords/half-bridge","display_name":"Half bridge","score":0.47952771186828613},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.478742778301239},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.44798898696899414},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.43019574880599976},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.4272177219390869},{"id":"https://openalex.org/keywords/\u0107uk-converter","display_name":"\u0106uk converter","score":0.4218844175338745},{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.419084370136261},{"id":"https://openalex.org/keywords/boost-converter","display_name":"Boost converter","score":0.41900867223739624},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.3959563970565796},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.34415775537490845},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.28011763095855713},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.274011492729187},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2706390917301178},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.16290748119354248},{"id":"https://openalex.org/keywords/capacitor","display_name":"Capacitor","score":0.13085874915122986}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.7466837763786316},{"id":"https://openalex.org/C2986056383","wikidata":"https://www.wikidata.org/wiki/Q556030","display_name":"Power flow","level":4,"score":0.6125308275222778},{"id":"https://openalex.org/C55118286","wikidata":"https://www.wikidata.org/wiki/Q634739","display_name":"Forward converter","level":4,"score":0.5988983511924744},{"id":"https://openalex.org/C103303742","wikidata":"https://www.wikidata.org/wiki/Q1293595","display_name":"Flyback converter","level":4,"score":0.5804927945137024},{"id":"https://openalex.org/C3019968007","wikidata":"https://www.wikidata.org/wiki/Q5641793","display_name":"Half bridge","level":4,"score":0.47952771186828613},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.478742778301239},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.44798898696899414},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.43019574880599976},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.4272177219390869},{"id":"https://openalex.org/C100329506","wikidata":"https://www.wikidata.org/wiki/Q336439","display_name":"\u0106uk converter","level":4,"score":0.4218844175338745},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.419084370136261},{"id":"https://openalex.org/C78336795","wikidata":"https://www.wikidata.org/wiki/Q760134","display_name":"Boost converter","level":3,"score":0.41900867223739624},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.3959563970565796},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.34415775537490845},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.28011763095855713},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.274011492729187},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2706390917301178},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.16290748119354248},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.13085874915122986},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon.2017.8216245","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2017.8216245","pdf_url":null,"source":{"id":"https://openalex.org/S4363608531","display_name":"IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.8799999952316284,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320334764","display_name":"Japan Society for the Promotion of Science","ror":"https://ror.org/00hhkn466"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":19,"referenced_works":["https://openalex.org/W1966751624","https://openalex.org/W2021147968","https://openalex.org/W2036980618","https://openalex.org/W2071133126","https://openalex.org/W2095914876","https://openalex.org/W2110938228","https://openalex.org/W2115013297","https://openalex.org/W2130353148","https://openalex.org/W2203940449","https://openalex.org/W2479777380","https://openalex.org/W2496167047","https://openalex.org/W2518053432","https://openalex.org/W2571200753","https://openalex.org/W2588225004","https://openalex.org/W2588616105","https://openalex.org/W2735937952","https://openalex.org/W2742851395","https://openalex.org/W6668012104","https://openalex.org/W6674605837"],"related_works":["https://openalex.org/W2588047361","https://openalex.org/W2783344684","https://openalex.org/W2119349318","https://openalex.org/W2126740233","https://openalex.org/W2545560698","https://openalex.org/W4388894028","https://openalex.org/W4293193861","https://openalex.org/W1539693063","https://openalex.org/W2040795866","https://openalex.org/W1486866994"],"abstract_inverted_index":{"We":[0,40,154],"propose":[1],"an":[2,103,126,139],"autonomous":[3],"hybrid":[4],"AC/DC":[5,127,140],"microgrid":[6,38,94],"system":[7],"that":[8,24,57,82,133],"uses":[9],"a":[10,17,42,111,116,121,157],"triple":[11],"active":[12],"bridge":[13],"(TAB)":[14],"converter":[15,23,45,123,136,141],"as":[16],"power":[18,29,63,68,80,85,98,107,161],"routing":[19],"unit.":[20],"A":[21,78],"TAB":[22,44,122,135],"can":[25,59,83,142],"independently":[26],"control":[27,60,109,143,162,188],"transmission":[28,62,160],"among":[30],"three":[31,74],"ports":[32,164],"is":[33,70,90],"suitable":[34],"for":[35,92,159],"constructing":[36],"the":[37,61,65,76,106,134,144,150,171,175,182,187],"system.":[39],"made":[41],"prototype":[43],"rated":[46],"at":[47],"400":[48],"V,":[49],"20":[50],"kHz,":[51],"and":[52,55,88,115,146],"10":[53],"kW":[54],"demonstrated":[56,181],"it":[58],"when":[64],"stabilized":[66],"DC":[67,89],"supply":[69],"connected":[71],"to":[72],"all":[73],"of":[75,149,174,186],"ports.":[77],"three-port":[79],"router":[81],"transmit":[84],"between":[86,110,163],"AC":[87,113],"essential":[91],"enabling":[93],"systems":[95],"including":[96],"both":[97],"sources.":[99],"This":[100],"paper":[101],"describes":[102],"experiment":[104],"on":[105],"flow":[108],"three-phase":[112],"source":[114],"lithium":[117,151],"ion":[118,152],"battery":[119],"using":[120],"equipped":[124,137],"with":[125,138],"converter.":[128],"The":[129,178],"experimental":[130],"results":[131,180],"show":[132],"charge":[145],"discharge":[147],"amounts":[148],"battery.":[153],"also":[155],"investigated":[156],"method":[158],"having":[165],"mutually":[166],"different":[167],"voltages":[168],"by":[169],"controlling":[170],"pulse":[172],"widths":[173],"inverter":[176],"voltage.":[177],"simulation":[179],"loss":[183],"reduction":[184],"effect":[185],"method.":[189]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2019,"cited_by_count":3},{"year":2018,"cited_by_count":3}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
