{"id":"https://openalex.org/W2773094852","doi":"https://doi.org/10.1109/iecon.2017.8216131","title":"An accurate active power sharing study in virtual flux angle droop method","display_name":"An accurate active power sharing study in virtual flux angle droop method","publication_year":2017,"publication_date":"2017-10-01","ids":{"openalex":"https://openalex.org/W2773094852","doi":"https://doi.org/10.1109/iecon.2017.8216131","mag":"2773094852"},"language":"en","primary_location":{"id":"doi:10.1109/iecon.2017.8216131","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2017.8216131","pdf_url":null,"source":{"id":"https://openalex.org/S4363608531","display_name":"IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5002108382","display_name":"Aimeng Wang","orcid":null},"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Aimeng Wang","raw_affiliation_strings":["State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Baoding, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Baoding, China","institution_ids":["https://openalex.org/I153473198"]}]},{"author_position":"last","author":{"id":null,"display_name":"Jia Zhang","orcid":null},"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jia Zhang","raw_affiliation_strings":["State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Baoding, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Baoding, China","institution_ids":["https://openalex.org/I153473198"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I153473198"],"apc_list":null,"apc_paid":null,"fwci":0.4415,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.55368372,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":"36","issue":null,"first_page":"756","last_page":"761"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":0.9975000023841858,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.9930999875068665,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/voltage-droop","display_name":"Voltage droop","score":0.9900640249252319},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.7639939785003662},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.7099739909172058},{"id":"https://openalex.org/keywords/compensation","display_name":"Compensation (psychology)","score":0.6680883169174194},{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.6246010065078735},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.5857446193695068},{"id":"https://openalex.org/keywords/automatic-frequency-control","display_name":"Automatic frequency control","score":0.5076001882553101},{"id":"https://openalex.org/keywords/flux","display_name":"Flux (metallurgy)","score":0.4894622564315796},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.46138647198677063},{"id":"https://openalex.org/keywords/power-control","display_name":"Power control","score":0.41495418548583984},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3358052372932434},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.29049474000930786},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.10772979259490967},{"id":"https://openalex.org/keywords/voltage-regulator","display_name":"Voltage regulator","score":0.09014755487442017},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.06581136584281921},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.06235578656196594}],"concepts":[{"id":"https://openalex.org/C40760162","wikidata":"https://www.wikidata.org/wiki/Q10920295","display_name":"Voltage droop","level":4,"score":0.9900640249252319},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.7639939785003662},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.7099739909172058},{"id":"https://openalex.org/C2780023022","wikidata":"https://www.wikidata.org/wiki/Q1338171","display_name":"Compensation (psychology)","level":2,"score":0.6680883169174194},{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.6246010065078735},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.5857446193695068},{"id":"https://openalex.org/C25915539","wikidata":"https://www.wikidata.org/wiki/Q220786","display_name":"Automatic frequency control","level":2,"score":0.5076001882553101},{"id":"https://openalex.org/C68709404","wikidata":"https://www.wikidata.org/wiki/Q1134475","display_name":"Flux (metallurgy)","level":2,"score":0.4894622564315796},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.46138647198677063},{"id":"https://openalex.org/C56685638","wikidata":"https://www.wikidata.org/wiki/Q2300474","display_name":"Power control","level":3,"score":0.41495418548583984},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3358052372932434},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.29049474000930786},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.10772979259490967},{"id":"https://openalex.org/C110706871","wikidata":"https://www.wikidata.org/wiki/Q851210","display_name":"Voltage regulator","level":3,"score":0.09014755487442017},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.06581136584281921},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.06235578656196594},{"id":"https://openalex.org/C11171543","wikidata":"https://www.wikidata.org/wiki/Q41630","display_name":"Psychoanalysis","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C15744967","wikidata":"https://www.wikidata.org/wiki/Q9418","display_name":"Psychology","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C191897082","wikidata":"https://www.wikidata.org/wiki/Q11467","display_name":"Metallurgy","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon.2017.8216131","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2017.8216131","pdf_url":null,"source":{"id":"https://openalex.org/S4363608531","display_name":"IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.8399999737739563}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W2073330654","https://openalex.org/W2113997357","https://openalex.org/W2150333046","https://openalex.org/W2154944026","https://openalex.org/W2162156389","https://openalex.org/W2162636717","https://openalex.org/W2312246008","https://openalex.org/W2349132584","https://openalex.org/W2383265812","https://openalex.org/W6683931818"],"related_works":["https://openalex.org/W2541499041","https://openalex.org/W2996453113","https://openalex.org/W3215487687","https://openalex.org/W2743608321","https://openalex.org/W1968880006","https://openalex.org/W1521491911","https://openalex.org/W2057687962","https://openalex.org/W2116408040","https://openalex.org/W2789378410","https://openalex.org/W2775545405"],"abstract_inverted_index":{"This":[0],"paper":[1],"investigates":[2],"the":[3,31,40,83,110],"problem":[4],"of":[5,25,128],"accurate":[6,74,116],"active":[7,44,59,75,85],"power":[8,45,60,76,86,117],"sharing":[9,46,77],"in":[10,47,96],"virtual":[11,32,91],"flux":[12,15,33,48,66,92],"droop":[13,17,28,34,50,68,93],"where":[14],"angle":[16,49,67],"control":[18,35,69,112,130],"is":[19,37,63,94],"used":[20],"for":[21,42],"DG":[22],"controllers":[23],"instead":[24],"traditional":[26],"frequency":[27,121],"control.":[29],"Firstly,":[30],"method":[36],"introduced.":[38],"Then,":[39],"reasons":[41],"inaccurate":[43],"are":[51],"analysed.":[52],"Further,":[53],"to":[54,65],"solve":[55],"this":[56],"problem,":[57],"an":[58],"compensation":[61,87],"sheme":[62],"added":[64],"loop,":[70],"which":[71],"can":[72,114],"achieve":[73,115],"without":[78],"affecting":[79],"system":[80],"stability.":[81],"Finally,":[82],"proposed":[84,111],"strategy":[88,113],"based":[89],"on":[90],"verified":[95],"a":[97],"simplified":[98],"microgrid":[99],"model":[100],"with":[101],"two":[102],"parallel":[103],"DGs.":[104],"The":[105],"simulation":[106],"results":[107],"show":[108],"that":[109],"distribution":[118],"and":[119,124,131,134],"zero":[120],"deviation":[122],"simutaneously":[123],"also":[125],"has":[126],"advantages":[127],"simple":[129],"excellent":[132],"dynamic":[133],"static":[135],"performance.":[136]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2019,"cited_by_count":1}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
