{"id":"https://openalex.org/W2772622743","doi":"https://doi.org/10.1109/iecon.2017.8216055","title":"LCL filter design for a modular power conditioning system with uninterruptible power supply capability","display_name":"LCL filter design for a modular power conditioning system with uninterruptible power supply capability","publication_year":2017,"publication_date":"2017-10-01","ids":{"openalex":"https://openalex.org/W2772622743","doi":"https://doi.org/10.1109/iecon.2017.8216055","mag":"2772622743"},"language":"en","primary_location":{"id":"doi:10.1109/iecon.2017.8216055","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2017.8216055","pdf_url":null,"source":{"id":"https://openalex.org/S4363608531","display_name":"IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5004572382","display_name":"Florian Bendrat","orcid":"https://orcid.org/0000-0002-6308-8690"},"institutions":[{"id":"https://openalex.org/I904495901","display_name":"Ruhr University Bochum","ror":"https://ror.org/04tsk2644","country_code":"DE","type":"education","lineage":["https://openalex.org/I904495901"]}],"countries":["DE"],"is_corresponding":true,"raw_author_name":"Florian Bendrat","raw_affiliation_strings":["Department of Electrical Engineering and Information Technology, Ruhr-University Bochum, Bochum, Germany"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering and Information Technology, Ruhr-University Bochum, Bochum, Germany","institution_ids":["https://openalex.org/I904495901"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5040862249","display_name":"Johnny Chhor","orcid":"https://orcid.org/0000-0001-8597-2658"},"institutions":[{"id":"https://openalex.org/I904495901","display_name":"Ruhr University Bochum","ror":"https://ror.org/04tsk2644","country_code":"DE","type":"education","lineage":["https://openalex.org/I904495901"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Johnny Chhor","raw_affiliation_strings":["Department of Electrical Engineering and Information Technology, Ruhr-University Bochum, Bochum, Germany"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering and Information Technology, Ruhr-University Bochum, Bochum, Germany","institution_ids":["https://openalex.org/I904495901"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5038189908","display_name":"Constantinos Sourkounis","orcid":"https://orcid.org/0000-0002-7340-1636"},"institutions":[{"id":"https://openalex.org/I904495901","display_name":"Ruhr University Bochum","ror":"https://ror.org/04tsk2644","country_code":"DE","type":"education","lineage":["https://openalex.org/I904495901"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Constantinos Sourkounis","raw_affiliation_strings":["Department of Electrical Engineering and Information Technology, Ruhr-University Bochum, Bochum, Germany"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering and Information Technology, Ruhr-University Bochum, Bochum, Germany","institution_ids":["https://openalex.org/I904495901"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5004572382"],"corresponding_institution_ids":["https://openalex.org/I904495901"],"apc_list":null,"apc_paid":null,"fwci":2.1642,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.86938776,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"303","last_page":"309"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9987999796867371,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":0.9975000023841858,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/uninterruptible-power-supply","display_name":"Uninterruptible power supply","score":0.9048105478286743},{"id":"https://openalex.org/keywords/modular-design","display_name":"Modular design","score":0.6735324859619141},{"id":"https://openalex.org/keywords/switched-mode-power-supply","display_name":"Switched-mode power supply","score":0.6410596966743469},{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.5897414684295654},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.512782633304596},{"id":"https://openalex.org/keywords/power-conditioner","display_name":"Power conditioner","score":0.48947417736053467},{"id":"https://openalex.org/keywords/filter","display_name":"Filter (signal processing)","score":0.45640408992767334},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.43816858530044556},{"id":"https://openalex.org/keywords/power-supply-unit","display_name":"Power supply unit","score":0.43366336822509766},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4161233901977539},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.4147060215473175},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.4131402373313904},{"id":"https://openalex.org/keywords/switched-mode-power-supply-applications","display_name":"Switched-mode power supply applications","score":0.4107493758201599},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.38715440034866333},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.3519596755504608},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.23866474628448486},{"id":"https://openalex.org/keywords/constant-power-circuit","display_name":"Constant power circuit","score":0.11387553811073303}],"concepts":[{"id":"https://openalex.org/C2988808934","wikidata":"https://www.wikidata.org/wiki/Q207696","display_name":"Uninterruptible power supply","level":3,"score":0.9048105478286743},{"id":"https://openalex.org/C101468663","wikidata":"https://www.wikidata.org/wiki/Q1620158","display_name":"Modular design","level":2,"score":0.6735324859619141},{"id":"https://openalex.org/C151799858","wikidata":"https://www.wikidata.org/wiki/Q587008","display_name":"Switched-mode power supply","level":3,"score":0.6410596966743469},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.5897414684295654},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.512782633304596},{"id":"https://openalex.org/C2780765089","wikidata":"https://www.wikidata.org/wiki/Q1326101","display_name":"Power conditioner","level":4,"score":0.48947417736053467},{"id":"https://openalex.org/C106131492","wikidata":"https://www.wikidata.org/wiki/Q3072260","display_name":"Filter (signal processing)","level":2,"score":0.45640408992767334},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.43816858530044556},{"id":"https://openalex.org/C37454539","wikidata":"https://www.wikidata.org/wiki/Q3972","display_name":"Power supply unit","level":3,"score":0.43366336822509766},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4161233901977539},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4147060215473175},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4131402373313904},{"id":"https://openalex.org/C79899660","wikidata":"https://www.wikidata.org/wiki/Q587008","display_name":"Switched-mode power supply applications","level":5,"score":0.4107493758201599},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.38715440034866333},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3519596755504608},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.23866474628448486},{"id":"https://openalex.org/C29586797","wikidata":"https://www.wikidata.org/wiki/Q5163663","display_name":"Constant power circuit","level":4,"score":0.11387553811073303},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon.2017.8216055","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2017.8216055","pdf_url":null,"source":{"id":"https://openalex.org/S4363608531","display_name":"IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":23,"referenced_works":["https://openalex.org/W1834350974","https://openalex.org/W1976113763","https://openalex.org/W1985922231","https://openalex.org/W2012483874","https://openalex.org/W2022180998","https://openalex.org/W2053469672","https://openalex.org/W2075794102","https://openalex.org/W2098893648","https://openalex.org/W2106652244","https://openalex.org/W2108196484","https://openalex.org/W2110801212","https://openalex.org/W2117032398","https://openalex.org/W2122740310","https://openalex.org/W2122858263","https://openalex.org/W2129669526","https://openalex.org/W2131191410","https://openalex.org/W2145317868","https://openalex.org/W2148532820","https://openalex.org/W2279582073","https://openalex.org/W2538385005","https://openalex.org/W2590458594","https://openalex.org/W2737235972","https://openalex.org/W6653840111"],"related_works":["https://openalex.org/W2740815748","https://openalex.org/W4393106611","https://openalex.org/W2356496350","https://openalex.org/W2371073454","https://openalex.org/W2041292831","https://openalex.org/W2359850098","https://openalex.org/W2161429030","https://openalex.org/W1484535147","https://openalex.org/W2022367912","https://openalex.org/W2772622743"],"abstract_inverted_index":{"Low":[0],"power":[1,22,44,61],"quality":[2,31],"and":[3,76],"supply":[4,33,62],"reliability":[5],"within":[6,34],"industrial":[7,35],"grids":[8,36],"cause":[9],"severe":[10],"economic":[11],"damage":[12],"to":[13,53,80],"Europe's":[14],"key":[15],"industry":[16],"sectors.":[17],"A":[18],"modular":[19],"shunt":[20],"connected":[21],"conditioning":[23],"systems":[24],"with":[25],"the":[26,67,85],"objective":[27],"of":[28,32,41,55,89],"locally":[29],"improving":[30],"has":[37],"been":[38],"proposed.":[39],"One":[40],"its":[42,72],"voltage-fed":[43],"converter":[45],"based":[46],"modules":[47],"implements":[48],"functionalities":[49],"which":[50],"are":[51],"comparable":[52],"those":[54],"well":[56],"known":[57],"line":[58],"interactive":[59],"uninterruptible":[60],"systems.":[63],"This":[64],"paper":[65],"discusses":[66],"input":[68],"filter":[69,87],"topology":[70],"choice,":[71],"application":[73],"specific":[74],"design":[75,88],"points":[77],"out":[78],"contrasts":[79],"optimization":[81],"criteria":[82],"derived":[83],"for":[84,91],"LCL":[86],"converters":[90],"permanent":[92],"grid-connected":[93],"operation.":[94]},"counts_by_year":[{"year":2021,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":2},{"year":2017,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}