{"id":"https://openalex.org/W1996506737","doi":"https://doi.org/10.1109/iecon.2013.6700413","title":"Low-voltage ride-through techniques for DFIG-based wind turbines: state-of-the-art review and future trends","display_name":"Low-voltage ride-through techniques for DFIG-based wind turbines: state-of-the-art review and future trends","publication_year":2013,"publication_date":"2013-11-01","ids":{"openalex":"https://openalex.org/W1996506737","doi":"https://doi.org/10.1109/iecon.2013.6700413","mag":"1996506737"},"language":"en","primary_location":{"id":"doi:10.1109/iecon.2013.6700413","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2013.6700413","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5033007353","display_name":"Marwa Ezzat","orcid":"https://orcid.org/0000-0002-4465-5194"},"institutions":[{"id":"https://openalex.org/I159247623","display_name":"Mansoura University","ror":"https://ror.org/01k8vtd75","country_code":"EG","type":"education","lineage":["https://openalex.org/I159247623"]}],"countries":["EG"],"is_corresponding":true,"raw_author_name":"Marwa Ezzat","raw_affiliation_strings":["Department of Electrical Engineering, Mansoura University, Mansoura, Egypt","Dept. of Electr. Eng., Mansoura Univ., Mansoura, Egypt"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Mansoura University, Mansoura, Egypt","institution_ids":["https://openalex.org/I159247623"]},{"raw_affiliation_string":"Dept. of Electr. Eng., Mansoura Univ., Mansoura, Egypt","institution_ids":["https://openalex.org/I159247623"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5035730211","display_name":"Mohamed Benbouzid","orcid":"https://orcid.org/0000-0002-4844-508X"},"institutions":[{"id":"https://openalex.org/I161929037","display_name":"Universit\u00e9 de Bretagne Occidentale","ror":"https://ror.org/01b8h3982","country_code":"FR","type":"education","lineage":["https://openalex.org/I161929037"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Mohamed Benbouzid","raw_affiliation_strings":["University of Brest, Brest, France","LBMS, Univ. of Brest, Brest, France"],"affiliations":[{"raw_affiliation_string":"University of Brest, Brest, France","institution_ids":["https://openalex.org/I161929037"]},{"raw_affiliation_string":"LBMS, Univ. of Brest, Brest, France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5028098322","display_name":"S. M. Muyeen","orcid":null},"institutions":[{"id":"https://openalex.org/I4210087059","display_name":"Technology Innovation Institute","ror":"https://ror.org/001kv2y39","country_code":"AE","type":"facility","lineage":["https://openalex.org/I4210087059"]}],"countries":["AE"],"is_corresponding":false,"raw_author_name":"S.M. Muyeen","raw_affiliation_strings":["Electrical Engineering Department, Petroleum Institute, Abu Dhabi, United Arab Emirates","Electr. Eng. Dept., Pet. Inst., Abu Dhabi, United Arab Emirates"],"affiliations":[{"raw_affiliation_string":"Electrical Engineering Department, Petroleum Institute, Abu Dhabi, United Arab Emirates","institution_ids":[]},{"raw_affiliation_string":"Electr. Eng. Dept., Pet. Inst., Abu Dhabi, United Arab Emirates","institution_ids":["https://openalex.org/I4210087059"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5083571879","display_name":"Lennart Harnefors","orcid":"https://orcid.org/0000-0002-3107-7073"},"institutions":[{"id":"https://openalex.org/I4210086503","display_name":"ABB (Sweden)","ror":"https://ror.org/0033n4009","country_code":"SE","type":"company","lineage":["https://openalex.org/I4210086503","https://openalex.org/I885143765"]}],"countries":["SE"],"is_corresponding":false,"raw_author_name":"Lennart Harnefors","raw_affiliation_strings":["Corporate Research V\u00e4ster\u00e5s, Sweden","Corp. Res., ABB AB, Vasteras, Sweden"],"affiliations":[{"raw_affiliation_string":"Corporate Research V\u00e4ster\u00e5s, Sweden","institution_ids":[]},{"raw_affiliation_string":"Corp. Res., ABB AB, Vasteras, Sweden","institution_ids":["https://openalex.org/I4210086503"]}]}],"institutions":[],"countries_distinct_count":4,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5033007353"],"corresponding_institution_ids":["https://openalex.org/I159247623"],"apc_list":null,"apc_paid":null,"fwci":3.8467,"has_fulltext":false,"cited_by_count":70,"citation_normalized_percentile":{"value":0.93708688,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":96,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"7681","last_page":"7686"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9984999895095825,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.9959999918937683,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/low-voltage-ride-through","display_name":"Low voltage ride through","score":0.861375093460083},{"id":"https://openalex.org/keywords/overvoltage","display_name":"Overvoltage","score":0.7104364633560181},{"id":"https://openalex.org/keywords/wind-power","display_name":"Wind power","score":0.6894683837890625},{"id":"https://openalex.org/keywords/inrush-current","display_name":"Inrush current","score":0.657279372215271},{"id":"https://openalex.org/keywords/induction-generator","display_name":"Induction generator","score":0.6389347314834595},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.48059460520744324},{"id":"https://openalex.org/keywords/voltage-sag","display_name":"Voltage sag","score":0.46576428413391113},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.4398549795150757},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4195355474948883},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4081539809703827},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.40649059414863586},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.3899616301059723},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.3895875811576843},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.37052005529403687},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.3536745011806488},{"id":"https://openalex.org/keywords/low-voltage","display_name":"Low voltage","score":0.34963226318359375},{"id":"https://openalex.org/keywords/power-quality","display_name":"Power quality","score":0.21063217520713806},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.0938156247138977}],"concepts":[{"id":"https://openalex.org/C2780438294","wikidata":"https://www.wikidata.org/wiki/Q6693052","display_name":"Low voltage ride through","level":4,"score":0.861375093460083},{"id":"https://openalex.org/C15703209","wikidata":"https://www.wikidata.org/wiki/Q333883","display_name":"Overvoltage","level":3,"score":0.7104364633560181},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.6894683837890625},{"id":"https://openalex.org/C23340480","wikidata":"https://www.wikidata.org/wiki/Q358932","display_name":"Inrush current","level":4,"score":0.657279372215271},{"id":"https://openalex.org/C98716924","wikidata":"https://www.wikidata.org/wiki/Q752750","display_name":"Induction generator","level":3,"score":0.6389347314834595},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.48059460520744324},{"id":"https://openalex.org/C2781134633","wikidata":"https://www.wikidata.org/wiki/Q14945479","display_name":"Voltage sag","level":4,"score":0.46576428413391113},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.4398549795150757},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4195355474948883},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4081539809703827},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.40649059414863586},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3899616301059723},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.3895875811576843},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.37052005529403687},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3536745011806488},{"id":"https://openalex.org/C128624480","wikidata":"https://www.wikidata.org/wiki/Q1504817","display_name":"Low voltage","level":3,"score":0.34963226318359375},{"id":"https://openalex.org/C2779665505","wikidata":"https://www.wikidata.org/wiki/Q1780079","display_name":"Power quality","level":3,"score":0.21063217520713806},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.0938156247138977},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/iecon.2013.6700413","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2013.6700413","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},{"id":"pmh:oai:espace.curtin.edu.au:20.500.11937/3661","is_oa":false,"landing_page_url":"http://hdl.handle.net/20.500.11937/3661","pdf_url":null,"source":{"id":"https://openalex.org/S4306401790","display_name":"eSpace (Curtin University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205640436","host_organization_name":"Curtin University","host_organization_lineage":["https://openalex.org/I205640436"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Conference Paper"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8999999761581421,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":37,"referenced_works":["https://openalex.org/W148660737","https://openalex.org/W1819133625","https://openalex.org/W1968522699","https://openalex.org/W1988455632","https://openalex.org/W1991181079","https://openalex.org/W2003411222","https://openalex.org/W2005865938","https://openalex.org/W2008351778","https://openalex.org/W2013212195","https://openalex.org/W2019161952","https://openalex.org/W2020067468","https://openalex.org/W2021085927","https://openalex.org/W2022564383","https://openalex.org/W2022862717","https://openalex.org/W2027815559","https://openalex.org/W2034773686","https://openalex.org/W2035005889","https://openalex.org/W2044917847","https://openalex.org/W2057377982","https://openalex.org/W2057970054","https://openalex.org/W2078871156","https://openalex.org/W2080837654","https://openalex.org/W2087700250","https://openalex.org/W2094995413","https://openalex.org/W2100267072","https://openalex.org/W2100959566","https://openalex.org/W2102406524","https://openalex.org/W2106119713","https://openalex.org/W2116625059","https://openalex.org/W2120459443","https://openalex.org/W2129398593","https://openalex.org/W2143991453","https://openalex.org/W2161832815","https://openalex.org/W2171982351","https://openalex.org/W2490618246","https://openalex.org/W2596832621","https://openalex.org/W6638464968"],"related_works":["https://openalex.org/W2387355095","https://openalex.org/W2912800709","https://openalex.org/W2971840042","https://openalex.org/W2039901959","https://openalex.org/W1553417096","https://openalex.org/W2787711088","https://openalex.org/W3024680038","https://openalex.org/W2083276236","https://openalex.org/W3147084305","https://openalex.org/W2063529504"],"abstract_inverted_index":{"This":[0,23,69],"paper":[1,171],"deals":[2],"with":[3,73],"low-voltage":[4],"ride-through":[5],"(LVRT)":[6],"capability":[7,166],"of":[8,26,33,39,81,180],"wind":[9,34],"turbines":[10],"(WTs)":[11],"and":[12,64,101,130,154],"in":[13,41,47,71,168],"particular":[14],"those":[15],"driven":[16],"by":[17],"a":[18,66,159,176],"doubly-fed":[19],"induction":[20],"generator":[21,155],"(DFIG).":[22],"is":[24,91,136,158,172],"one":[25],"the":[27,42,57,61,79,107,127,131,140,146,151,183],"biggest":[28],"challenges":[29],"facing":[30],"massive":[31],"deployment":[32],"farms.":[35],"With":[36],"increasing":[37],"penetration":[38],"WTs":[40,52,94],"grid,":[43],"grid":[44,58],"connection":[45],"codes":[46],"most":[48],"countries":[49],"require":[50],"that":[51,124],"should":[53],"remain":[54],"connected":[55],"to":[56,59,95,97,117,138,149,182,190,196],"maintain":[60],"reliability":[62],"during":[63,100,145],"after":[65,102],"short-term":[67],"fault.":[68],"results":[70],"LVRT":[72,108,165,184],"only":[74],"15%":[75],"remaining":[76],"voltage":[77,147],"at":[78],"point":[80],"common":[82],"coupling":[83],"(PCC),":[84],"possibly":[85],"even":[86],"less.":[87],"In":[88],"addition,":[89],"it":[90,135],"required":[92,137],"for":[93,110,164],"contribute":[96],"system":[98],"stability":[99],"fault":[103],"clearance.":[104],"To":[105],"fulfill":[106],"requirement":[109],"DFIG-based":[111],"WTs,":[112],"there":[113],"are":[114,188],"two":[115],"problems":[116],"be":[118],"addressed,":[119],"namely,":[120],"rotor":[121],"inrush":[122],"current":[123],"may":[125],"exceed":[126],"converter":[128],"limit":[129,139],"dc-link":[132],"overvoltage.":[133],"Further,":[134],"DFIG":[141],"transient":[142],"response":[143],"oscillations":[144],"sag":[148],"increase":[150],"gear":[152],"lifetime":[153],"reliability.":[156],"There":[157],"rich":[160],"literature":[161],"addressing":[162],"countermeasures":[163],"enhancement":[167],"DFIGs;":[169],"this":[170],"therefore":[173],"intended":[174],"as":[175,195],"comprehensive":[177],"state-of-the-art":[178],"review":[179],"solutions":[181],"issue.":[185],"Moreover,":[186],"attempts":[187],"made":[189],"highlight":[191],"future":[192],"issues":[193],"so":[194],"index":[197],"some":[198],"emerging":[199],"solutions.":[200]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2024,"cited_by_count":6},{"year":2023,"cited_by_count":4},{"year":2022,"cited_by_count":5},{"year":2021,"cited_by_count":5},{"year":2020,"cited_by_count":8},{"year":2019,"cited_by_count":4},{"year":2018,"cited_by_count":12},{"year":2017,"cited_by_count":9},{"year":2016,"cited_by_count":8},{"year":2015,"cited_by_count":5},{"year":2014,"cited_by_count":3}],"updated_date":"2026-03-27T14:29:43.386196","created_date":"2025-10-10T00:00:00"}
