{"id":"https://openalex.org/W1983625830","doi":"https://doi.org/10.1109/iecon.2012.6389334","title":"A new topology and control strategy for centralized ride-through capability of wind farm","display_name":"A new topology and control strategy for centralized ride-through capability of wind farm","publication_year":2012,"publication_date":"2012-10-01","ids":{"openalex":"https://openalex.org/W1983625830","doi":"https://doi.org/10.1109/iecon.2012.6389334","mag":"1983625830"},"language":"en","primary_location":{"id":"doi:10.1109/iecon.2012.6389334","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2012.6389334","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5069509238","display_name":"Lucheng Hong","orcid":"https://orcid.org/0000-0001-7109-5252"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Lucheng Hong","raw_affiliation_strings":["Tsinghua University, Beijing, China"],"affiliations":[{"raw_affiliation_string":"Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5113818177","display_name":"Qirong Jiang","orcid":"https://orcid.org/0009-0003-3145-6406"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Qirong Jiang","raw_affiliation_strings":["Tsinghua University, Beijing, China"],"affiliations":[{"raw_affiliation_string":"Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100786660","display_name":"Liang Wang","orcid":"https://orcid.org/0000-0003-2056-7883"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Liang Wang","raw_affiliation_strings":["Tsinghua University, Beijing, China"],"affiliations":[{"raw_affiliation_string":"Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100572979","display_name":"Du Wei","orcid":"https://orcid.org/0000-0003-1215-2223"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Wei Du","raw_affiliation_strings":["Tsinghua University, Beijing, China"],"affiliations":[{"raw_affiliation_string":"Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5069509238"],"corresponding_institution_ids":["https://openalex.org/I99065089"],"apc_list":null,"apc_paid":null,"fwci":0.982,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.77194085,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":"26","issue":null,"first_page":"3516","last_page":"3520"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9958000183105469,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9939000010490417,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/low-voltage-ride-through","display_name":"Low voltage ride through","score":0.8199601173400879},{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.6340439915657043},{"id":"https://openalex.org/keywords/pulse-width-modulation","display_name":"Pulse-width modulation","score":0.6193503141403198},{"id":"https://openalex.org/keywords/wind-power","display_name":"Wind power","score":0.6098566055297852},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.543498158454895},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.5201911926269531},{"id":"https://openalex.org/keywords/capacitor","display_name":"Capacitor","score":0.4876023828983307},{"id":"https://openalex.org/keywords/topology","display_name":"Topology (electrical circuits)","score":0.4660528600215912},{"id":"https://openalex.org/keywords/modular-design","display_name":"Modular design","score":0.4617929458618164},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.41757529973983765},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4005865454673767},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.39101460576057434},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.345048189163208},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.3434918522834778},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.26987549662590027},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.07079857587814331}],"concepts":[{"id":"https://openalex.org/C2780438294","wikidata":"https://www.wikidata.org/wiki/Q6693052","display_name":"Low voltage ride through","level":4,"score":0.8199601173400879},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.6340439915657043},{"id":"https://openalex.org/C92746544","wikidata":"https://www.wikidata.org/wiki/Q585184","display_name":"Pulse-width modulation","level":3,"score":0.6193503141403198},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.6098566055297852},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.543498158454895},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5201911926269531},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.4876023828983307},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.4660528600215912},{"id":"https://openalex.org/C101468663","wikidata":"https://www.wikidata.org/wiki/Q1620158","display_name":"Modular design","level":2,"score":0.4617929458618164},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.41757529973983765},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4005865454673767},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.39101460576057434},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.345048189163208},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.3434918522834778},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.26987549662590027},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.07079857587814331},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon.2012.6389334","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2012.6389334","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8999999761581421,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":11,"referenced_works":["https://openalex.org/W92189220","https://openalex.org/W1915388693","https://openalex.org/W2028994355","https://openalex.org/W2111134324","https://openalex.org/W2122498491","https://openalex.org/W2123746471","https://openalex.org/W2129937288","https://openalex.org/W2134836408","https://openalex.org/W2165542296","https://openalex.org/W3041565047","https://openalex.org/W6603735254"],"related_works":["https://openalex.org/W631083485","https://openalex.org/W4313452936","https://openalex.org/W2097026685","https://openalex.org/W2480068220","https://openalex.org/W2102542442","https://openalex.org/W1986220761","https://openalex.org/W2070883797","https://openalex.org/W2042495646","https://openalex.org/W4386859288","https://openalex.org/W2161636646"],"abstract_inverted_index":{"As":[0],"the":[1,104,116,127,130],"penetration":[2],"of":[3,60,84,103,129],"large-scale":[4],"grid-connected":[5,24],"wind":[6,25,61,77],"farms":[7,26],"increasing":[8],"year":[9],"by":[10,28],"year,":[11],"low":[12],"voltage":[13,41,80,90],"ride-through":[14],"(LVRT)":[15],"capability":[16,59],"has":[17],"been":[18],"an":[19],"extremely":[20],"important":[21],"criterion":[22],"for":[23],"required":[27],"many":[29],"countries":[30],"to":[31,56,75,125],"improve":[32,57],"power":[33],"quality":[34],"at":[35],"grid":[36],"fault.":[37],"A":[38],"new":[39],"dynamic":[40],"restorer":[42],"(DVR)":[43],"topology":[44,97],"based":[45],"on":[46,100],"modular":[47],"multilevel":[48],"converters":[49],"(MMC)":[50],"is":[51,98],"proposed":[52,131],"in":[53,87,113],"this":[54],"paper":[55],"LVRT":[58],"farms.":[62],"Related":[63],"control":[64,118],"strategies":[65],"and":[66,82,133,137],"pulse":[67],"width":[68],"modulation":[69],"(PWM)":[70],"method":[71],"are":[72,122,139],"also":[73],"proposed,":[74],"keep":[76],"farm":[78],"terminal":[79],"normal":[81],"voltages":[83,110],"MMC":[85],"fly-capacitors":[86],"balance":[88,114],"during":[89],"sag":[91],"period;":[92],"a":[93],"special":[94],"energy":[95],"sharing":[96],"applied":[99],"DC":[101,108],"sides":[102],"device,":[105],"three":[106],"phase":[107],"bus":[109],"can":[111],"kept":[112],"through":[115],"given":[117],"strategy.":[119],"PSCAD/EMTDC":[120],"simulations":[121],"carried":[123],"out":[124],"prove":[126],"effectiveness":[128],"technique":[132],"some":[134],"related":[135],"conclusions":[136],"comments":[138],"summarized.":[140]},"counts_by_year":[{"year":2017,"cited_by_count":1},{"year":2014,"cited_by_count":3},{"year":2013,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
