{"id":"https://openalex.org/W2030733964","doi":"https://doi.org/10.1109/iecon.2012.6388885","title":"Dual EKF estimator for fault detection and isolation in Heating Ventilation and Air Conditioning systems","display_name":"Dual EKF estimator for fault detection and isolation in Heating Ventilation and Air Conditioning systems","publication_year":2012,"publication_date":"2012-10-01","ids":{"openalex":"https://openalex.org/W2030733964","doi":"https://doi.org/10.1109/iecon.2012.6388885","mag":"2030733964"},"language":"en","primary_location":{"id":"doi:10.1109/iecon.2012.6388885","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2012.6388885","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5045730684","display_name":"Mohammed Zaheeruddin","orcid":"https://orcid.org/0000-0001-6450-1136"},"institutions":[{"id":"https://openalex.org/I60158472","display_name":"Concordia University","ror":"https://ror.org/0420zvk78","country_code":"CA","type":"education","lineage":["https://openalex.org/I60158472"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Mohammed Zaheeruddin","raw_affiliation_strings":["Concordia University, Montreal, QUE, Canada","Concordia University, 1455 De Maisonneuve Blvd. West, Montreal, Quebec, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Concordia University, Montreal, QUE, Canada","institution_ids":["https://openalex.org/I60158472"]},{"raw_affiliation_string":"Concordia University, 1455 De Maisonneuve Blvd. West, Montreal, Quebec, Canada","institution_ids":["https://openalex.org/I60158472"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5056811561","display_name":"Nicolae Tudoroiu","orcid":"https://orcid.org/0000-0001-6708-9132"},"institutions":[{"id":"https://openalex.org/I60158472","display_name":"Concordia University","ror":"https://ror.org/0420zvk78","country_code":"CA","type":"education","lineage":["https://openalex.org/I60158472"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Nicolae Tudoroiu","raw_affiliation_strings":["Concordia University, Montreal, QUE, Canada","Concordia University, 1455 De Maisonneuve Blvd. West, Montreal, Quebec, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Concordia University, Montreal, QUE, Canada","institution_ids":["https://openalex.org/I60158472"]},{"raw_affiliation_string":"Concordia University, 1455 De Maisonneuve Blvd. West, Montreal, Quebec, Canada","institution_ids":["https://openalex.org/I60158472"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I60158472"],"apc_list":null,"apc_paid":null,"fwci":1.6411,"has_fulltext":false,"cited_by_count":10,"citation_normalized_percentile":{"value":0.8057614,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"2257","last_page":"2262"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10663","display_name":"Advanced Battery Technologies Research","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11236","display_name":"Control Systems and Identification","score":0.9879999756813049,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hvac","display_name":"HVAC","score":0.8629292249679565},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.7210483551025391},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"Air conditioning","score":0.6554406881332397},{"id":"https://openalex.org/keywords/extended-kalman-filter","display_name":"Extended Kalman filter","score":0.5746073722839355},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.5421648025512695},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5278853178024292},{"id":"https://openalex.org/keywords/kalman-filter","display_name":"Kalman filter","score":0.5051282048225403},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.49898266792297363},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.4681181311607361},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.4512566030025482},{"id":"https://openalex.org/keywords/isolation","display_name":"Isolation (microbiology)","score":0.4503242075443268},{"id":"https://openalex.org/keywords/estimator","display_name":"Estimator","score":0.4100736975669861},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.37777984142303467},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.3690810203552246},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.35098838806152344},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.3479340672492981},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.15181007981300354},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.14587393403053284}],"concepts":[{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.8629292249679565},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.7210483551025391},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.6554406881332397},{"id":"https://openalex.org/C206833254","wikidata":"https://www.wikidata.org/wiki/Q5421817","display_name":"Extended Kalman filter","level":3,"score":0.5746073722839355},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5421648025512695},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5278853178024292},{"id":"https://openalex.org/C157286648","wikidata":"https://www.wikidata.org/wiki/Q846780","display_name":"Kalman filter","level":2,"score":0.5051282048225403},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.49898266792297363},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.4681181311607361},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.4512566030025482},{"id":"https://openalex.org/C2775941552","wikidata":"https://www.wikidata.org/wiki/Q25212305","display_name":"Isolation (microbiology)","level":2,"score":0.4503242075443268},{"id":"https://openalex.org/C185429906","wikidata":"https://www.wikidata.org/wiki/Q1130160","display_name":"Estimator","level":2,"score":0.4100736975669861},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.37777984142303467},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.3690810203552246},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.35098838806152344},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3479340672492981},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.15181007981300354},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.14587393403053284},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C89423630","wikidata":"https://www.wikidata.org/wiki/Q7193","display_name":"Microbiology","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon.2012.6388885","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2012.6388885","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":7,"referenced_works":["https://openalex.org/W1525941546","https://openalex.org/W1581808154","https://openalex.org/W2140123645","https://openalex.org/W2147063734","https://openalex.org/W2147428031","https://openalex.org/W2153307918","https://openalex.org/W2154671215"],"related_works":["https://openalex.org/W2112866972","https://openalex.org/W4240233711","https://openalex.org/W2900606913","https://openalex.org/W3046823714","https://openalex.org/W2348218441","https://openalex.org/W3021806226","https://openalex.org/W4205684936","https://openalex.org/W2103062922","https://openalex.org/W2162299404","https://openalex.org/W2118844790"],"abstract_inverted_index":{"Nowadays":[0],"to":[1,4,46,62,87,97,104,118],"monitor":[2],"and":[3,25,36,56,84,94,102,115,133,154],"control":[5],"the":[6,33,52,63,75,89,99,134,149],"recent":[7],"generation":[8],"of":[9,23,32,42,51,109,122,148],"high":[10],"complexity":[11],"Heating":[12],"Ventilation":[13],"Air":[14],"Conditioning":[15],"(HVAC)":[16],"building":[17],"systems":[18],"under":[19],"a":[20,48,119,130,142],"wide":[21,120],"variety":[22],"occupancy":[24],"load":[26],"related":[27],"operating":[28],"conditions":[29],"represents":[30],"one":[31],"most":[34],"difficult":[35],"challenging":[37],"task.":[38],"The":[39,107],"main":[40],"objective":[41],"this":[43,110],"study":[44],"is":[45,112,127],"develop":[47],"new":[49],"approach":[50,111],"fault":[53,100,135,144],"detection,":[54],"diagnosis":[55,136],"isolation":[57],"(FDDI)":[58],"automated":[59],"techniques":[60,71],"applied":[61],"valve":[64,91],"actuator":[65],"failures":[66],"in":[67,129,146],"HVAC":[68],"systems.":[69],"These":[70],"are":[72],"based":[73],"on":[74],"dual":[76],"Extended":[77],"Kalman":[78],"Filter":[79],"that":[80],"combines":[81],"state":[82],"estimation":[83,86],"parameter":[85],"detect":[88],"faulty":[90],"(stuck":[92],"opened":[93],"stuck":[95],"closed),":[96],"determine":[98],"severity":[101],"finally":[103],"isolate":[105],"it.":[106],"superiority":[108],"its":[113,116,155],"simplicity":[114],"application":[117],"range":[121],"similar":[123],"applications.":[124],"This":[125],"algorithm":[126],"implemented":[128],"simulation":[131],"environment,":[132],"results":[137],"could":[138],"be":[139],"evaluated":[140],"for":[141],"several":[143],"scenarios":[145],"terms":[147],"injection":[150],"fault,":[151],"detection":[152],"time,":[153],"severity.":[156]},"counts_by_year":[{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":3},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2014,"cited_by_count":2},{"year":2013,"cited_by_count":1}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}