{"id":"https://openalex.org/W1967716091","doi":"https://doi.org/10.1109/iecon.2012.6388828","title":"A high power and multi-outputs of AC-DC power supply design to meet 80 plus gold and ErP requirements","display_name":"A high power and multi-outputs of AC-DC power supply design to meet 80 plus gold and ErP requirements","publication_year":2012,"publication_date":"2012-10-01","ids":{"openalex":"https://openalex.org/W1967716091","doi":"https://doi.org/10.1109/iecon.2012.6388828","mag":"1967716091"},"language":"en","primary_location":{"id":"doi:10.1109/iecon.2012.6388828","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2012.6388828","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5068870258","display_name":"Shichen Liang","orcid":"https://orcid.org/0009-0002-0342-5242"},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"S.-A. Liang","raw_affiliation_strings":["Technique Development Department, FSP Group, FSP Technology, Inc., Taoyuan, Taiwan","Technique Development Department, FSP Technology Inc. FSP Group., No. 22, Jianguo E, Rd., Taoyuan City, Taiwan"],"affiliations":[{"raw_affiliation_string":"Technique Development Department, FSP Group, FSP Technology, Inc., Taoyuan, Taiwan","institution_ids":[]},{"raw_affiliation_string":"Technique Development Department, FSP Technology Inc. FSP Group., No. 22, Jianguo E, Rd., Taoyuan City, Taiwan","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5113522937","display_name":"Ching Wen Huang","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Ching Wen Huang","raw_affiliation_strings":["Technique Development Department, FSP Group, FSP Technology, Inc., Taoyuan, Taiwan","Technique Development Department, FSP Technology Inc. FSP Group., No. 22, Jianguo E, Rd., Taoyuan City, Taiwan"],"affiliations":[{"raw_affiliation_string":"Technique Development Department, FSP Group, FSP Technology, Inc., Taoyuan, Taiwan","institution_ids":[]},{"raw_affiliation_string":"Technique Development Department, FSP Technology Inc. FSP Group., No. 22, Jianguo E, Rd., Taoyuan City, Taiwan","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5078810349","display_name":"Po-Chang Lu","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Po-Chang Lu","raw_affiliation_strings":["Technique Development Department, FSP Group, FSP Technology, Inc., Taoyuan, Taiwan","Technique Development Department, FSP Technology Inc. FSP Group., No. 22, Jianguo E, Rd., Taoyuan City, Taiwan"],"affiliations":[{"raw_affiliation_string":"Technique Development Department, FSP Group, FSP Technology, Inc., Taoyuan, Taiwan","institution_ids":[]},{"raw_affiliation_string":"Technique Development Department, FSP Technology Inc. FSP Group., No. 22, Jianguo E, Rd., Taoyuan City, Taiwan","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5068870258"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.04598056,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"68","last_page":"73"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9983000159263611,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9983000159263611,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9574000239372253,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11444","display_name":"Electromagnetic Compatibility and Noise Suppression","score":0.953499972820282,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/duty-cycle","display_name":"Duty cycle","score":0.758806586265564},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.6156065464019775},{"id":"https://openalex.org/keywords/switched-mode-power-supply","display_name":"Switched-mode power supply","score":0.611327588558197},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.5356345772743225},{"id":"https://openalex.org/keywords/power-supply-unit","display_name":"Power supply unit","score":0.5107083320617676},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.498568058013916},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.4983854293823242},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4805734157562256},{"id":"https://openalex.org/keywords/power-control","display_name":"Power control","score":0.436326265335083},{"id":"https://openalex.org/keywords/power-density","display_name":"Power density","score":0.4228420853614807},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.33417022228240967},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.09487786889076233}],"concepts":[{"id":"https://openalex.org/C199822604","wikidata":"https://www.wikidata.org/wiki/Q557120","display_name":"Duty cycle","level":3,"score":0.758806586265564},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.6156065464019775},{"id":"https://openalex.org/C151799858","wikidata":"https://www.wikidata.org/wiki/Q587008","display_name":"Switched-mode power supply","level":3,"score":0.611327588558197},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5356345772743225},{"id":"https://openalex.org/C37454539","wikidata":"https://www.wikidata.org/wiki/Q3972","display_name":"Power supply unit","level":3,"score":0.5107083320617676},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.498568058013916},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4983854293823242},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4805734157562256},{"id":"https://openalex.org/C56685638","wikidata":"https://www.wikidata.org/wiki/Q2300474","display_name":"Power control","level":3,"score":0.436326265335083},{"id":"https://openalex.org/C21881925","wikidata":"https://www.wikidata.org/wiki/Q3503313","display_name":"Power density","level":3,"score":0.4228420853614807},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.33417022228240967},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.09487786889076233},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon.2012.6388828","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2012.6388828","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8700000047683716,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W1970661839","https://openalex.org/W2101487179","https://openalex.org/W2114883930","https://openalex.org/W2138597500","https://openalex.org/W2146011910"],"related_works":["https://openalex.org/W2553205681","https://openalex.org/W2740815748","https://openalex.org/W4393106611","https://openalex.org/W1544239096","https://openalex.org/W2356496350","https://openalex.org/W2380109908","https://openalex.org/W2041292831","https://openalex.org/W2366164503","https://openalex.org/W2359850098","https://openalex.org/W2355347665"],"abstract_inverted_index":{"In":[0,99],"this":[1],"paper,":[2,101],"the":[3,41,60,85,100,102],"soft-switching":[4],"LLC":[5],"half-bridge":[6],"resonant":[7,38],"converter":[8,39],"with":[9,22,36,47],"frequency":[10,44],"control":[11],"is":[12,106,116],"proposed":[13,29],"and":[14,55,63,79,95,108,118],"used":[15],"in":[16,59],"desktop":[17],"ATX":[18],"PC":[19,33,86,104,113],"power":[20,25,34,72,87],"supply":[21,35,88],"more":[23],"higher":[24],"applications.":[26],"The":[27],"new":[28,103],"simple":[30],"structure":[31],"of":[32,43],"multi-output":[37],"has":[40],"features":[42],"modulation":[45],"operation":[46,89],"fixed":[48],"duty":[49],"cycle,":[50],"zero":[51],"voltage":[52,57],"switching":[53,77],"(ZVS),":[54],"low":[56,76,80],"stress":[58],"active":[61],"switches":[62],"output":[64],"synchronous":[65],"rectifiers.":[66],"Moreover,":[67],"it":[68],"can":[69],"achieve":[70],"high":[71,74],"density,":[73],"efficiency,":[75],"losses":[78],"component":[81],"counts,":[82],"which":[83],"make":[84],"to":[90,120],"meet":[91],"80":[92],"Plus":[93],"Gold":[94],"2013":[96],"ErP":[97],"requirements.":[98],"topology":[105],"presented,":[107],"a":[109],"specific":[110],"example":[111],"for":[112],"1200W":[114],"application":[115],"designed":[117],"implemented":[119],"verify":[121],"its":[122],"feasibility.":[123]},"counts_by_year":[{"year":2022,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
