{"id":"https://openalex.org/W2080021324","doi":"https://doi.org/10.1109/iecon.2012.6388758","title":"Novel on-line maximum duty point tracking technique to improving server power efficiency meeting 80plus Gold code","display_name":"Novel on-line maximum duty point tracking technique to improving server power efficiency meeting 80plus Gold code","publication_year":2012,"publication_date":"2012-10-01","ids":{"openalex":"https://openalex.org/W2080021324","doi":"https://doi.org/10.1109/iecon.2012.6388758","mag":"2080021324"},"language":"en","primary_location":{"id":"doi:10.1109/iecon.2012.6388758","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2012.6388758","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5078730314","display_name":"Yen\u2010Shin Lai","orcid":"https://orcid.org/0000-0002-6490-3001"},"institutions":[{"id":"https://openalex.org/I118292597","display_name":"National Taipei University of Technology","ror":"https://ror.org/00cn92c09","country_code":"TW","type":"education","lineage":["https://openalex.org/I118292597"]}],"countries":["TW"],"is_corresponding":true,"raw_author_name":"Yen-Shin Lai","raw_affiliation_strings":["Center for Power Electronics, National Taipei University of Technology, Taipei, Taiwan","Center for Power Electronics, National Taipei University of Technology, Taiwan"],"affiliations":[{"raw_affiliation_string":"Center for Power Electronics, National Taipei University of Technology, Taipei, Taiwan","institution_ids":["https://openalex.org/I118292597"]},{"raw_affiliation_string":"Center for Power Electronics, National Taipei University of Technology, Taiwan","institution_ids":["https://openalex.org/I118292597"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5028703628","display_name":"Zih-Jie Su","orcid":null},"institutions":[{"id":"https://openalex.org/I118292597","display_name":"National Taipei University of Technology","ror":"https://ror.org/00cn92c09","country_code":"TW","type":"education","lineage":["https://openalex.org/I118292597"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Zih-Jie Su","raw_affiliation_strings":["Center for Power Electronics, National Taipei University of Technology, Taipei, Taiwan","Center for Power Electronics, National Taipei University of Technology, Taiwan"],"affiliations":[{"raw_affiliation_string":"Center for Power Electronics, National Taipei University of Technology, Taipei, Taiwan","institution_ids":["https://openalex.org/I118292597"]},{"raw_affiliation_string":"Center for Power Electronics, National Taipei University of Technology, Taiwan","institution_ids":["https://openalex.org/I118292597"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5078730314"],"corresponding_institution_ids":["https://openalex.org/I118292597"],"apc_list":null,"apc_paid":null,"fwci":0.491,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.6956318,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"609","last_page":"614"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9987000226974487,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/duty-cycle","display_name":"Duty cycle","score":0.6835195422172546},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5468324422836304},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.545194685459137},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.5177525877952576},{"id":"https://openalex.org/keywords/line","display_name":"Line (geometry)","score":0.48796194791793823},{"id":"https://openalex.org/keywords/point","display_name":"Point (geometry)","score":0.4202215075492859},{"id":"https://openalex.org/keywords/electrical-efficiency","display_name":"Electrical efficiency","score":0.4154888689517975},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.35777610540390015},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3573504686355591},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2843495011329651}],"concepts":[{"id":"https://openalex.org/C199822604","wikidata":"https://www.wikidata.org/wiki/Q557120","display_name":"Duty cycle","level":3,"score":0.6835195422172546},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5468324422836304},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.545194685459137},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5177525877952576},{"id":"https://openalex.org/C198352243","wikidata":"https://www.wikidata.org/wiki/Q37105","display_name":"Line (geometry)","level":2,"score":0.48796194791793823},{"id":"https://openalex.org/C28719098","wikidata":"https://www.wikidata.org/wiki/Q44946","display_name":"Point (geometry)","level":2,"score":0.4202215075492859},{"id":"https://openalex.org/C118993495","wikidata":"https://www.wikidata.org/wiki/Q5042828","display_name":"Electrical efficiency","level":3,"score":0.4154888689517975},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.35777610540390015},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3573504686355591},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2843495011329651},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon.2012.6388758","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2012.6388758","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.8999999761581421,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":23,"referenced_works":["https://openalex.org/W1831362705","https://openalex.org/W1969664284","https://openalex.org/W1988027644","https://openalex.org/W1991934523","https://openalex.org/W2052854484","https://openalex.org/W2088659119","https://openalex.org/W2110630904","https://openalex.org/W2116141929","https://openalex.org/W2121046381","https://openalex.org/W2121887567","https://openalex.org/W2122381462","https://openalex.org/W2122735423","https://openalex.org/W2125583254","https://openalex.org/W2125958939","https://openalex.org/W2131586048","https://openalex.org/W2133788217","https://openalex.org/W2144117691","https://openalex.org/W2147206619","https://openalex.org/W2160029424","https://openalex.org/W2162055832","https://openalex.org/W2163975980","https://openalex.org/W2166456503","https://openalex.org/W4245879290"],"related_works":["https://openalex.org/W2242290487","https://openalex.org/W2356676145","https://openalex.org/W2358939236","https://openalex.org/W4293055656","https://openalex.org/W2239330273","https://openalex.org/W2093858167","https://openalex.org/W2371953206","https://openalex.org/W2349543044","https://openalex.org/W2365728856","https://openalex.org/W2350406672"],"abstract_inverted_index":{"The":[0,25,35,91],"main":[1],"theme":[2],"of":[3,21,29,44,54,93,160],"this":[4],"paper":[5],"is":[6],"to":[7,17,49,130,146,148],"propose":[8],"a":[9],"novel":[10],"on-line":[11],"maximum":[12,51,163],"duty":[13,52,164],"point":[14,165],"tracking":[15,166],"technique":[16,38],"improve":[18],"the":[19,22,40,63,72,84,94,122,139,150,158,161],"efficiency":[20,64,123,140],"server":[23,26,95],"power.":[24],"power":[27,45,96,115],"consists":[28],"PFC":[30],"and":[31,70,113],"phase-shift":[32,55],"full-bridge":[33,56],"converter.":[34,57],"proposed":[36,162],"MDPT":[37],"controls":[39],"DC-link":[41],"bus":[42],"voltage":[43,101,109],"factor":[46],"corrector":[47],"(PFC)":[48],"retain":[50],"ratio":[53],"It":[58,134],"will":[59,135],"be":[60,67,125,136,143],"shown":[61,137],"that":[62,121,138],"can":[65,124,141],"therefore":[66,142],"improved":[68,126,144],"significantly":[69],"meet":[71,149],"80":[73,151],"plus":[74],"Gold":[75,153],"code.":[76,154],"Experimental":[77,118],"system":[78],"using":[79],"TI":[80],"DSP":[81],"(TMS320F2812)":[82],"as":[83],"control":[85],"platform":[86],"has":[87],"been":[88],"set":[89],"up.":[90],"specifications":[92],"supply":[97],"include:":[98],"AC":[99],"input":[100],"=":[102,110,116],"110":[103],"/":[104],"220":[105],"V,":[106],"DC":[107],"output":[108,114],"12":[111],"V":[112],"480W.":[117],"results":[119,156],"show":[120],"from":[127],"light":[128],"load":[129,132],"full":[131],"conditions.":[133],"up":[145],"2.3%":[147],"PLUS":[152],"These":[155],"confirm":[157],"effectiveness":[159],"technique.":[167]},"counts_by_year":[{"year":2013,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
