{"id":"https://openalex.org/W2077629749","doi":"https://doi.org/10.1109/icumt.2010.5676647","title":"Energy-efficient cooperative routing for multi-hop networks over Nakagami-m and Rice channels","display_name":"Energy-efficient cooperative routing for multi-hop networks over Nakagami-m and Rice channels","publication_year":2010,"publication_date":"2010-10-01","ids":{"openalex":"https://openalex.org/W2077629749","doi":"https://doi.org/10.1109/icumt.2010.5676647","mag":"2077629749"},"language":"en","primary_location":{"id":"doi:10.1109/icumt.2010.5676647","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icumt.2010.5676647","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"International Congress on Ultra Modern Telecommunications and Control Systems","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5031399182","display_name":"Asghar Taheri","orcid":"https://orcid.org/0000-0001-8266-3075"},"institutions":[{"id":"https://openalex.org/I67009956","display_name":"Iran University of Science and Technology","ror":"https://ror.org/01jw2p796","country_code":"IR","type":"education","lineage":["https://openalex.org/I67009956"]}],"countries":["IR"],"is_corresponding":true,"raw_author_name":"A. Taheri","raw_affiliation_strings":["Department of Electrical Engineering, Iran University of Science and Technology, Tehran, Iran","Department of Electrical Engineering, Iran University of Science and Technology, Tehran16846, Iran"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Iran University of Science and Technology, Tehran, Iran","institution_ids":["https://openalex.org/I67009956"]},{"raw_affiliation_string":"Department of Electrical Engineering, Iran University of Science and Technology, Tehran16846, Iran","institution_ids":["https://openalex.org/I67009956"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5050335827","display_name":"Bahman Abolhassani","orcid":"https://orcid.org/0000-0001-7135-6002"},"institutions":[{"id":"https://openalex.org/I67009956","display_name":"Iran University of Science and Technology","ror":"https://ror.org/01jw2p796","country_code":"IR","type":"education","lineage":["https://openalex.org/I67009956"]}],"countries":["IR"],"is_corresponding":false,"raw_author_name":"B. Abolhassani","raw_affiliation_strings":["Department of Electrical Engineering, Iran University of Science and Technology, Tehran, Iran","Department of Electrical Engineering, Iran University of Science and Technology, Tehran16846, Iran"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Iran University of Science and Technology, Tehran, Iran","institution_ids":["https://openalex.org/I67009956"]},{"raw_affiliation_string":"Department of Electrical Engineering, Iran University of Science and Technology, Tehran16846, Iran","institution_ids":["https://openalex.org/I67009956"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5031399182"],"corresponding_institution_ids":["https://openalex.org/I67009956"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.17268528,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"127","last_page":"133"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10796","display_name":"Cooperative Communication and Network Coding","score":1.0,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10796","display_name":"Cooperative Communication and Network Coding","score":1.0,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10246","display_name":"Mobile Ad Hoc Networks","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11392","display_name":"Energy Harvesting in Wireless Networks","score":0.9983999729156494,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hop","display_name":"Hop (telecommunications)","score":0.6529589891433716},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6020549535751343},{"id":"https://openalex.org/keywords/wireless-sensor-network","display_name":"Wireless sensor network","score":0.5781930685043335},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.5424138307571411},{"id":"https://openalex.org/keywords/routing-algorithm","display_name":"Routing algorithm","score":0.5149158239364624},{"id":"https://openalex.org/keywords/nakagami-distribution","display_name":"Nakagami distribution","score":0.5000252723693848},{"id":"https://openalex.org/keywords/node","display_name":"Node (physics)","score":0.49495643377304077},{"id":"https://openalex.org/keywords/routing","display_name":"Routing (electronic design automation)","score":0.49145495891571045},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.4874856472015381},{"id":"https://openalex.org/keywords/outage-probability","display_name":"Outage probability","score":0.4474385976791382},{"id":"https://openalex.org/keywords/topology","display_name":"Topology (electrical circuits)","score":0.44209519028663635},{"id":"https://openalex.org/keywords/channel","display_name":"Channel (broadcasting)","score":0.3256074786186218},{"id":"https://openalex.org/keywords/routing-protocol","display_name":"Routing protocol","score":0.3130304217338562},{"id":"https://openalex.org/keywords/fading","display_name":"Fading","score":0.27273881435394287},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.2319640815258026},{"id":"https://openalex.org/keywords/combinatorics","display_name":"Combinatorics","score":0.1834968626499176},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.14377275109291077},{"id":"https://openalex.org/keywords/statistics","display_name":"Statistics","score":0.12852996587753296}],"concepts":[{"id":"https://openalex.org/C25906391","wikidata":"https://www.wikidata.org/wiki/Q1432381","display_name":"Hop (telecommunications)","level":2,"score":0.6529589891433716},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6020549535751343},{"id":"https://openalex.org/C24590314","wikidata":"https://www.wikidata.org/wiki/Q336038","display_name":"Wireless sensor network","level":2,"score":0.5781930685043335},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.5424138307571411},{"id":"https://openalex.org/C2984173633","wikidata":"https://www.wikidata.org/wiki/Q22725","display_name":"Routing algorithm","level":4,"score":0.5149158239364624},{"id":"https://openalex.org/C115098869","wikidata":"https://www.wikidata.org/wiki/Q3258347","display_name":"Nakagami distribution","level":4,"score":0.5000252723693848},{"id":"https://openalex.org/C62611344","wikidata":"https://www.wikidata.org/wiki/Q1062658","display_name":"Node (physics)","level":2,"score":0.49495643377304077},{"id":"https://openalex.org/C74172769","wikidata":"https://www.wikidata.org/wiki/Q1446839","display_name":"Routing (electronic design automation)","level":2,"score":0.49145495891571045},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.4874856472015381},{"id":"https://openalex.org/C2778258436","wikidata":"https://www.wikidata.org/wiki/Q30672262","display_name":"Outage probability","level":4,"score":0.4474385976791382},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.44209519028663635},{"id":"https://openalex.org/C127162648","wikidata":"https://www.wikidata.org/wiki/Q16858953","display_name":"Channel (broadcasting)","level":2,"score":0.3256074786186218},{"id":"https://openalex.org/C104954878","wikidata":"https://www.wikidata.org/wiki/Q1648707","display_name":"Routing protocol","level":3,"score":0.3130304217338562},{"id":"https://openalex.org/C81978471","wikidata":"https://www.wikidata.org/wiki/Q1196572","display_name":"Fading","level":3,"score":0.27273881435394287},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.2319640815258026},{"id":"https://openalex.org/C114614502","wikidata":"https://www.wikidata.org/wiki/Q76592","display_name":"Combinatorics","level":1,"score":0.1834968626499176},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.14377275109291077},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.12852996587753296},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icumt.2010.5676647","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icumt.2010.5676647","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"International Congress on Ultra Modern Telecommunications and Control Systems","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.8899999856948853}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":15,"referenced_works":["https://openalex.org/W307194162","https://openalex.org/W2039017884","https://openalex.org/W2041564253","https://openalex.org/W2108427351","https://openalex.org/W2110801500","https://openalex.org/W2120448104","https://openalex.org/W2130347036","https://openalex.org/W2148963518","https://openalex.org/W2149476612","https://openalex.org/W2152121970","https://openalex.org/W2156499962","https://openalex.org/W2159616236","https://openalex.org/W3152133380","https://openalex.org/W6610904146","https://openalex.org/W6793551195"],"related_works":["https://openalex.org/W2062281036","https://openalex.org/W2126171054","https://openalex.org/W2030831987","https://openalex.org/W135017867","https://openalex.org/W2026252359","https://openalex.org/W2140821840","https://openalex.org/W2041402509","https://openalex.org/W1965243394","https://openalex.org/W1996421073","https://openalex.org/W2186678463"],"abstract_inverted_index":{"In":[0,24,54,126],"this":[1,55],"paper,":[2,56],"the":[3,17,33,41,45,59,63,77,96,109,120,150,157],"problem":[4],"of":[5,19,62,89,112,124,159],"energy":[6,84,103,129,160],"saving":[7,85,104],"in":[8],"cooperative":[9,79],"multi-hop":[10,91],"wireless":[11],"sensor":[12],"networks":[13],"is":[14,117,134,144,148],"studied":[15],"with":[16,44,119],"constraint":[18],"a":[20],"given":[21],"outage":[22,68,122],"probability.":[23],"these":[25,71,127],"networks,":[26],"each":[27],"node":[28],"transmits":[29],"its":[30],"signal":[31],"to":[32,65,87,101,132],"next":[34],"m":[35,113,140],"<sub":[36,114,141],"xmlns:mml=\"http://www.w3.org/1998/Math/MathML\"":[37,115,142],"xmlns:xlink=\"http://www.w3.org/1999/xlink\">coop</sub>":[38,116,143],"nodes":[39],"on":[40,156],"route":[42],"ending":[43],"sink":[46],"node.":[47],"Rice":[48,137,151],"and":[49,146],"Nakagami":[50],"channels":[51,107,138],"are":[52],"considered.":[53],"we":[57],"derive":[58],"upper":[60],"bound":[61],"end":[64,66],"(e-2-e)":[67],"probability":[69,123],"for":[70],"networks.":[72],"Numerical":[73],"results":[74],"show":[75,94],"that":[76,88,95],"proposed":[78,97],"routing":[80],"can":[81],"provide":[82],"considerable":[83],"compared":[86],"non-cooperative":[90],"transmission.":[92],"Results":[93],"network":[98],"achieves":[99],"up":[100,131],"74%":[102],"over":[105,136],"Nakagami-2":[106],"when":[108,139],"optimum":[110],"number":[111],"three":[118],"maximum":[121],"10-4.":[125],"conditions,":[128],"savings":[130],"95%":[133],"achieved":[135],"four":[145],"it":[147],"shown":[149],"parameter":[152],"has":[153],"no":[154],"effect":[155],"amount":[158],"saving.":[161]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
