{"id":"https://openalex.org/W4310009643","doi":"https://doi.org/10.1109/ictc55196.2022.9952509","title":"Non-communication Protection Scheme for Meshed Distribution Systems using a New Time-Current-Voltage Characteristic","display_name":"Non-communication Protection Scheme for Meshed Distribution Systems using a New Time-Current-Voltage Characteristic","publication_year":2022,"publication_date":"2022-10-19","ids":{"openalex":"https://openalex.org/W4310009643","doi":"https://doi.org/10.1109/ictc55196.2022.9952509"},"language":"en","primary_location":{"id":"doi:10.1109/ictc55196.2022.9952509","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ictc55196.2022.9952509","pdf_url":null,"source":{"id":"https://openalex.org/S4363607740","display_name":"2022 13th International Conference on Information and Communication Technology Convergence (ICTC)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 13th International Conference on Information and Communication Technology Convergence (ICTC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5059120812","display_name":"Dongyob Shin","orcid":null},"institutions":[{"id":"https://openalex.org/I197347611","display_name":"Korea University","ror":"https://ror.org/047dqcg40","country_code":"KR","type":"education","lineage":["https://openalex.org/I197347611"]}],"countries":["KR"],"is_corresponding":true,"raw_author_name":"Dongyob Shin","raw_affiliation_strings":["School of Electrical Engineering, Korea University,Seoul,Republic of Korea","School of Electrical Engineering, Korea University, Seoul, Republic of Korea"],"affiliations":[{"raw_affiliation_string":"School of Electrical Engineering, Korea University,Seoul,Republic of Korea","institution_ids":["https://openalex.org/I197347611"]},{"raw_affiliation_string":"School of Electrical Engineering, Korea University, Seoul, Republic of Korea","institution_ids":["https://openalex.org/I197347611"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5101422461","display_name":"Sungyun Choi","orcid":"https://orcid.org/0000-0001-8802-2535"},"institutions":[{"id":"https://openalex.org/I197347611","display_name":"Korea University","ror":"https://ror.org/047dqcg40","country_code":"KR","type":"education","lineage":["https://openalex.org/I197347611"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Sungyun Choi","raw_affiliation_strings":["School of Electrical Engineering, Korea University,Seoul,Republic of Korea","School of Electrical Engineering, Korea University, Seoul, Republic of Korea"],"affiliations":[{"raw_affiliation_string":"School of Electrical Engineering, Korea University,Seoul,Republic of Korea","institution_ids":["https://openalex.org/I197347611"]},{"raw_affiliation_string":"School of Electrical Engineering, Korea University, Seoul, Republic of Korea","institution_ids":["https://openalex.org/I197347611"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5059120812"],"corresponding_institution_ids":["https://openalex.org/I197347611"],"apc_list":null,"apc_paid":null,"fwci":0.3539,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.45419616,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"350","last_page":"353"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9959999918937683,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":0.9821000099182129,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/backup","display_name":"Backup","score":0.7671217918395996},{"id":"https://openalex.org/keywords/relay","display_name":"Relay","score":0.7533383369445801},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.618870198726654},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.60014808177948},{"id":"https://openalex.org/keywords/scheme","display_name":"Scheme (mathematics)","score":0.5610954761505127},{"id":"https://openalex.org/keywords/reduction","display_name":"Reduction (mathematics)","score":0.4953362047672272},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.4926310181617737},{"id":"https://openalex.org/keywords/power-system-protection","display_name":"Power-system protection","score":0.4886687099933624},{"id":"https://openalex.org/keywords/communications-system","display_name":"Communications system","score":0.4750880300998688},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4571824073791504},{"id":"https://openalex.org/keywords/current","display_name":"Current (fluid)","score":0.42546582221984863},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3880596458911896},{"id":"https://openalex.org/keywords/topology","display_name":"Topology (electrical circuits)","score":0.365191787481308},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.32713741064071655},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.1985766887664795},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.13579681515693665},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.07553413510322571}],"concepts":[{"id":"https://openalex.org/C2780945871","wikidata":"https://www.wikidata.org/wiki/Q194274","display_name":"Backup","level":2,"score":0.7671217918395996},{"id":"https://openalex.org/C2778156585","wikidata":"https://www.wikidata.org/wiki/Q174053","display_name":"Relay","level":3,"score":0.7533383369445801},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.618870198726654},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.60014808177948},{"id":"https://openalex.org/C77618280","wikidata":"https://www.wikidata.org/wiki/Q1155772","display_name":"Scheme (mathematics)","level":2,"score":0.5610954761505127},{"id":"https://openalex.org/C111335779","wikidata":"https://www.wikidata.org/wiki/Q3454686","display_name":"Reduction (mathematics)","level":2,"score":0.4953362047672272},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4926310181617737},{"id":"https://openalex.org/C38361682","wikidata":"https://www.wikidata.org/wiki/Q1756067","display_name":"Power-system protection","level":4,"score":0.4886687099933624},{"id":"https://openalex.org/C101765175","wikidata":"https://www.wikidata.org/wiki/Q577764","display_name":"Communications system","level":2,"score":0.4750880300998688},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4571824073791504},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.42546582221984863},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3880596458911896},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.365191787481308},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.32713741064071655},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.1985766887664795},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.13579681515693665},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.07553413510322571},{"id":"https://openalex.org/C77088390","wikidata":"https://www.wikidata.org/wiki/Q8513","display_name":"Database","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ictc55196.2022.9952509","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ictc55196.2022.9952509","pdf_url":null,"source":{"id":"https://openalex.org/S4363607740","display_name":"2022 13th International Conference on Information and Communication Technology Convergence (ICTC)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 13th International Conference on Information and Communication Technology Convergence (ICTC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W2085257739","https://openalex.org/W2548966991","https://openalex.org/W2643736666","https://openalex.org/W2909470262","https://openalex.org/W3092317320"],"related_works":["https://openalex.org/W3147010029","https://openalex.org/W2018175133","https://openalex.org/W2124906373","https://openalex.org/W2992202700","https://openalex.org/W2140785999","https://openalex.org/W2349410032","https://openalex.org/W2391106504","https://openalex.org/W2135690429","https://openalex.org/W1964318283","https://openalex.org/W2320970856"],"abstract_inverted_index":{"This":[0],"paper":[1],"uses":[2],"a":[3,8,48,89,103],"new":[4,90],"time-current-voltage":[5,67,91],"characteristic":[6,92],"for":[7,117],"non-communication":[9],"protection":[10,18,32,37],"scheme":[11,19,44],"in":[12,30,106],"meshed":[13,62,120],"distribution":[14,63,121],"systems.":[15,122],"The":[16,42,65,84],"proposed":[17,43,66],"does":[20],"not":[21],"require":[22],"any":[23],"communication":[24],"system":[25,96],"and":[26,81,101],"will":[27],"be":[28,58],"applied":[29],"backup":[31],"coordination":[33,38],"when":[34],"the":[35,52,61,94,119],"primary":[36],"fails":[39],"with":[40,71],"communication.":[41],"is":[45,69],"verified":[46],"by":[47],"simulation":[49],"study":[50],"using":[51,88],"IEEE":[53],"14-bus":[54],"system,":[55],"which":[56],"can":[57],"defined":[59],"as":[60],"system.":[64],"curve":[68],"tested":[70],"numerical":[72],"test":[73],"cases,":[74],"including":[75],"various":[76],"fault":[77,79,82,99],"locations,":[78],"types,":[80],"resistance.":[83],"results":[85],"revealed":[86],"that":[87],"protects":[93],"entire":[95],"regardless":[97],"of":[98],"conditions":[100],"achieves":[102],"significant":[104],"reduction":[105],"total":[107],"relay":[108],"operating":[109],"time,":[110],"thus":[111],"making":[112],"such":[113],"relays":[114],"more":[115],"suitable":[116],"protecting":[118]},"counts_by_year":[{"year":2023,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}