{"id":"https://openalex.org/W3117949617","doi":"https://doi.org/10.1109/ictc49870.2020.9289200","title":"Impact of Data Center Cooling Technology to Effectiveness of Turbo-Mode","display_name":"Impact of Data Center Cooling Technology to Effectiveness of Turbo-Mode","publication_year":2020,"publication_date":"2020-10-21","ids":{"openalex":"https://openalex.org/W3117949617","doi":"https://doi.org/10.1109/ictc49870.2020.9289200","mag":"3117949617"},"language":"en","primary_location":{"id":"doi:10.1109/ictc49870.2020.9289200","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ictc49870.2020.9289200","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 International Conference on Information and Communication Technology Convergence (ICTC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5032947813","display_name":"Jaehyong Shin","orcid":null},"institutions":[{"id":"https://openalex.org/I2250650973","display_name":"Samsung (South Korea)","ror":"https://ror.org/04w3jy968","country_code":"KR","type":"company","lineage":["https://openalex.org/I2250650973"]},{"id":"https://openalex.org/I848706","display_name":"Sungkyunkwan University","ror":"https://ror.org/04q78tk20","country_code":"KR","type":"education","lineage":["https://openalex.org/I848706"]}],"countries":["KR"],"is_corresponding":true,"raw_author_name":"Jaehyong Shin","raw_affiliation_strings":["Data Center Group, DIT Center, Samsung Electronics Co., Ltd, Sungkyunkwan University, Suwon, Korea"],"affiliations":[{"raw_affiliation_string":"Data Center Group, DIT Center, Samsung Electronics Co., Ltd, Sungkyunkwan University, Suwon, Korea","institution_ids":["https://openalex.org/I848706","https://openalex.org/I2250650973"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5062665275","display_name":"Euiseong Seo","orcid":"https://orcid.org/0000-0003-2103-8019"},"institutions":[{"id":"https://openalex.org/I848706","display_name":"Sungkyunkwan University","ror":"https://ror.org/04q78tk20","country_code":"KR","type":"education","lineage":["https://openalex.org/I848706"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Euiseong Seo","raw_affiliation_strings":["Sungkyunkwan University, Suwon, Korea"],"affiliations":[{"raw_affiliation_string":"Sungkyunkwan University, Suwon, Korea","institution_ids":["https://openalex.org/I848706"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5032947813"],"corresponding_institution_ids":["https://openalex.org/I2250650973","https://openalex.org/I848706"],"apc_list":null,"apc_paid":null,"fwci":0.6931,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.69352497,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"1691","last_page":"1693"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10054","display_name":"Parallel Computing and Optimization Techniques","score":0.9987999796867371,"subfield":{"id":"https://openalex.org/subfields/1708","display_name":"Hardware and Architecture"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10054","display_name":"Parallel Computing and Optimization Techniques","score":0.9987999796867371,"subfield":{"id":"https://openalex.org/subfields/1708","display_name":"Hardware and Architecture"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10998","display_name":"Heat Transfer and Optimization","score":0.9955000281333923,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10101","display_name":"Cloud Computing and Resource Management","score":0.983299970626831,"subfield":{"id":"https://openalex.org/subfields/1710","display_name":"Information Systems"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-cooling","display_name":"Computer cooling","score":0.8617666363716125},{"id":"https://openalex.org/keywords/data-center","display_name":"Data center","score":0.6672861576080322},{"id":"https://openalex.org/keywords/turbo","display_name":"Turbo","score":0.5971046090126038},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.5750250816345215},{"id":"https://openalex.org/keywords/mode","display_name":"Mode (computer interface)","score":0.5505936741828918},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5405120253562927},{"id":"https://openalex.org/keywords/water-cooling","display_name":"Water cooling","score":0.5225077271461487},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.49586018919944763},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.49437522888183594},{"id":"https://openalex.org/keywords/performance-improvement","display_name":"Performance improvement","score":0.49226847290992737},{"id":"https://openalex.org/keywords/margin","display_name":"Margin (machine learning)","score":0.4199655055999756},{"id":"https://openalex.org/keywords/air-cooling","display_name":"Air cooling","score":0.41239774227142334},{"id":"https://openalex.org/keywords/nuclear-engineering","display_name":"Nuclear engineering","score":0.3925885558128357},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.32621127367019653},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.23427215218544006},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.21766376495361328},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.19518747925758362},{"id":"https://openalex.org/keywords/thermal-management-of-electronic-devices-and-systems","display_name":"Thermal management of electronic devices and systems","score":0.170109361410141},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.12897926568984985},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.08366584777832031}],"concepts":[{"id":"https://openalex.org/C11026015","wikidata":"https://www.wikidata.org/wiki/Q840551","display_name":"Computer cooling","level":3,"score":0.8617666363716125},{"id":"https://openalex.org/C153740404","wikidata":"https://www.wikidata.org/wiki/Q671224","display_name":"Data center","level":2,"score":0.6672861576080322},{"id":"https://openalex.org/C2776240298","wikidata":"https://www.wikidata.org/wiki/Q1138513","display_name":"Turbo","level":2,"score":0.5971046090126038},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.5750250816345215},{"id":"https://openalex.org/C48677424","wikidata":"https://www.wikidata.org/wiki/Q6888088","display_name":"Mode (computer interface)","level":2,"score":0.5505936741828918},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5405120253562927},{"id":"https://openalex.org/C7694927","wikidata":"https://www.wikidata.org/wiki/Q7667810","display_name":"Water cooling","level":2,"score":0.5225077271461487},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.49586018919944763},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.49437522888183594},{"id":"https://openalex.org/C2778915421","wikidata":"https://www.wikidata.org/wiki/Q3643177","display_name":"Performance improvement","level":2,"score":0.49226847290992737},{"id":"https://openalex.org/C774472","wikidata":"https://www.wikidata.org/wiki/Q6760393","display_name":"Margin (machine learning)","level":2,"score":0.4199655055999756},{"id":"https://openalex.org/C105873366","wikidata":"https://www.wikidata.org/wiki/Q1208873","display_name":"Air cooling","level":2,"score":0.41239774227142334},{"id":"https://openalex.org/C116915560","wikidata":"https://www.wikidata.org/wiki/Q83504","display_name":"Nuclear engineering","level":1,"score":0.3925885558128357},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.32621127367019653},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.23427215218544006},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.21766376495361328},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.19518747925758362},{"id":"https://openalex.org/C114834414","wikidata":"https://www.wikidata.org/wiki/Q15477170","display_name":"Thermal management of electronic devices and systems","level":2,"score":0.170109361410141},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.12897926568984985},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.08366584777832031},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C119857082","wikidata":"https://www.wikidata.org/wiki/Q2539","display_name":"Machine learning","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ictc49870.2020.9289200","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ictc49870.2020.9289200","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 International Conference on Information and Communication Technology Convergence (ICTC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.9100000262260437,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W2131568089","https://openalex.org/W2134926818","https://openalex.org/W2216340950","https://openalex.org/W2417690246","https://openalex.org/W2950306067"],"related_works":["https://openalex.org/W4384158534","https://openalex.org/W2071424948","https://openalex.org/W3085254884","https://openalex.org/W2343074808","https://openalex.org/W2343005181","https://openalex.org/W4312768595","https://openalex.org/W4384158516","https://openalex.org/W2018160174","https://openalex.org/W4387328855","https://openalex.org/W4384158605"],"abstract_inverted_index":{"The":[0,16],"importance":[1],"of":[2,90,101,107,141,144],"cooling":[3,18,68,79,92],"and":[4,10,51,94,97],"energy":[5,27],"efficiency":[6],"is":[7,22,69,137],"getting":[8],"more":[9,11],"important":[12],"in":[13,112,150],"data":[14],"centers.":[15],"liquid":[17,67,78,126,159],"technology":[19],"for":[20,25,39],"CPUs":[21,62],"well":[23],"known":[24],"its":[26],"efficiency.":[28],"In":[29,71],"addition,":[30],"it":[31],"provides":[32],"performance":[33,65,84,122,142,154],"improvement":[34,85,123,143],"by":[35,155],"enriching":[36],"the":[37,45,49,88,91,95,102,115,117,119,121,138],"opportunity":[38],"turbo":[40,145],"mode,":[41],"which":[42],"temporarily":[43],"boost":[44],"clock":[46],"frequency":[47],"when":[48,66],"temperature":[50,133],"power":[52,98],"consumption":[53,99],"conditions":[54],"stay":[55],"below":[56],"predefined":[57],"thresholds.":[58],"However,":[59],"not":[60],"all":[61],"show":[63],"improved":[64,153],"applied.":[70],"this":[72,113],"paper,":[73,114],"we":[74,109],"experimentally":[75],"reveal":[76,110],"that":[77,131],"has":[80,152],"different":[81],"effects":[82],"on":[83,87],"depending":[86],"design":[89],"device":[93],"thermal":[96],"characteristics":[100],"processor.":[103],"Through":[104],"a":[105],"series":[106],"experiments,":[108],"that,":[111],"higher":[116],"TDP,":[118],"greater":[120],"obtainable":[124],"through":[125],"cooling.":[127,160],"We":[128],"also":[129],"identify":[130],"distributed":[132],"sensing":[134],"(DTS)":[135],"margin":[136],"main":[139],"cause":[140],"mode.":[146],"Intel's":[147],"200Watt":[148],"CPU,":[149],"particular,":[151],"4.7%":[156],"due":[157],"to":[158]},"counts_by_year":[{"year":2023,"cited_by_count":2},{"year":2021,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
