{"id":"https://openalex.org/W2290476049","doi":"https://doi.org/10.1109/ict-dm.2015.7402059","title":"Fast deployment of an energy-efficient heterogeneous wireless network for disaster management","display_name":"Fast deployment of an energy-efficient heterogeneous wireless network for disaster management","publication_year":2015,"publication_date":"2015-11-01","ids":{"openalex":"https://openalex.org/W2290476049","doi":"https://doi.org/10.1109/ict-dm.2015.7402059","mag":"2290476049"},"language":"en","primary_location":{"id":"doi:10.1109/ict-dm.2015.7402059","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ict-dm.2015.7402059","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 2nd International Conference on Information and Communication Technologies for Disaster Management (ICT-DM)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5085604063","display_name":"Mohamed Aymen Chalouf","orcid":"https://orcid.org/0000-0002-4653-7837"},"institutions":[{"id":"https://openalex.org/I2802519937","display_name":"Institut de Recherche en Informatique et Syst\u00e8mes Al\u00e9atoires","ror":"https://ror.org/00myn0z94","country_code":"FR","type":"facility","lineage":["https://openalex.org/I1294671590","https://openalex.org/I1294671590","https://openalex.org/I1326498283","https://openalex.org/I205703379","https://openalex.org/I2802204017","https://openalex.org/I2802519937","https://openalex.org/I28221208","https://openalex.org/I4210127572","https://openalex.org/I4210159245","https://openalex.org/I56067802"]},{"id":"https://openalex.org/I56067802","display_name":"Universit\u00e9 de Rennes","ror":"https://ror.org/015m7wh34","country_code":"FR","type":"education","lineage":["https://openalex.org/I56067802"]}],"countries":["FR"],"is_corresponding":true,"raw_author_name":"Mohamed Aymen Chalouf","raw_affiliation_strings":["IRISA, University of Rennes 1, Lannion, France"],"affiliations":[{"raw_affiliation_string":"IRISA, University of Rennes 1, Lannion, France","institution_ids":["https://openalex.org/I2802519937","https://openalex.org/I56067802"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5025433714","display_name":"Martin Peres","orcid":null},"institutions":[{"id":"https://openalex.org/I4210160189","display_name":"Institut Polytechnique de Bordeaux","ror":"https://ror.org/054qv7y42","country_code":"FR","type":"education","lineage":["https://openalex.org/I4210160189"]},{"id":"https://openalex.org/I15057530","display_name":"Universit\u00e9 de Bordeaux","ror":"https://ror.org/057qpr032","country_code":"FR","type":"education","lineage":["https://openalex.org/I15057530"]},{"id":"https://openalex.org/I4210142254","display_name":"Laboratoire Bordelais de Recherche en Informatique","ror":"https://ror.org/03adqg323","country_code":"FR","type":"facility","lineage":["https://openalex.org/I1294671590","https://openalex.org/I1294671590","https://openalex.org/I15057530","https://openalex.org/I4210142254","https://openalex.org/I4210159245","https://openalex.org/I4210160189"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Martin Peres","raw_affiliation_strings":["LaBRI, University of Bordeaux, Talence, France"],"affiliations":[{"raw_affiliation_string":"LaBRI, University of Bordeaux, Talence, France","institution_ids":["https://openalex.org/I15057530","https://openalex.org/I4210142254","https://openalex.org/I4210160189"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5068063856","display_name":"Francine Krief","orcid":"https://orcid.org/0000-0003-4702-9305"},"institutions":[{"id":"https://openalex.org/I4210142254","display_name":"Laboratoire Bordelais de Recherche en Informatique","ror":"https://ror.org/03adqg323","country_code":"FR","type":"facility","lineage":["https://openalex.org/I1294671590","https://openalex.org/I1294671590","https://openalex.org/I15057530","https://openalex.org/I4210142254","https://openalex.org/I4210159245","https://openalex.org/I4210160189"]},{"id":"https://openalex.org/I15057530","display_name":"Universit\u00e9 de Bordeaux","ror":"https://ror.org/057qpr032","country_code":"FR","type":"education","lineage":["https://openalex.org/I15057530"]},{"id":"https://openalex.org/I4210160189","display_name":"Institut Polytechnique de Bordeaux","ror":"https://ror.org/054qv7y42","country_code":"FR","type":"education","lineage":["https://openalex.org/I4210160189"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Francine Krief","raw_affiliation_strings":["LaBRI, University of Bordeaux, Talence, France"],"affiliations":[{"raw_affiliation_string":"LaBRI, University of Bordeaux, Talence, France","institution_ids":["https://openalex.org/I15057530","https://openalex.org/I4210142254","https://openalex.org/I4210160189"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5085604063"],"corresponding_institution_ids":["https://openalex.org/I2802519937","https://openalex.org/I56067802"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.17056203,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"49","last_page":"56"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11896","display_name":"Opportunistic and Delay-Tolerant Networks","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11896","display_name":"Opportunistic and Delay-Tolerant Networks","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10246","display_name":"Mobile Ad Hoc Networks","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10080","display_name":"Energy Efficient Wireless Sensor Networks","score":0.9983000159263611,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/usable","display_name":"USable","score":0.7841106653213501},{"id":"https://openalex.org/keywords/software-deployment","display_name":"Software deployment","score":0.7612898945808411},{"id":"https://openalex.org/keywords/emergency-management","display_name":"Emergency management","score":0.6235073804855347},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6216875910758972},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.6078977584838867},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.5202606916427612},{"id":"https://openalex.org/keywords/wireless-network","display_name":"Wireless network","score":0.517113447189331},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.515217125415802},{"id":"https://openalex.org/keywords/heterogeneous-network","display_name":"Heterogeneous network","score":0.497052937746048},{"id":"https://openalex.org/keywords/sustainability","display_name":"Sustainability","score":0.44815242290496826},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.4389106035232544},{"id":"https://openalex.org/keywords/computer-security","display_name":"Computer security","score":0.4365319609642029},{"id":"https://openalex.org/keywords/disaster-recovery","display_name":"Disaster recovery","score":0.4200412333011627},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.4125615954399109},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.1888566017150879},{"id":"https://openalex.org/keywords/world-wide-web","display_name":"World Wide Web","score":0.08581021428108215},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.06870844960212708}],"concepts":[{"id":"https://openalex.org/C2780615836","wikidata":"https://www.wikidata.org/wiki/Q2471869","display_name":"USable","level":2,"score":0.7841106653213501},{"id":"https://openalex.org/C105339364","wikidata":"https://www.wikidata.org/wiki/Q2297740","display_name":"Software deployment","level":2,"score":0.7612898945808411},{"id":"https://openalex.org/C62555980","wikidata":"https://www.wikidata.org/wiki/Q1460420","display_name":"Emergency management","level":2,"score":0.6235073804855347},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6216875910758972},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.6078977584838867},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.5202606916427612},{"id":"https://openalex.org/C108037233","wikidata":"https://www.wikidata.org/wiki/Q11375","display_name":"Wireless network","level":3,"score":0.517113447189331},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.515217125415802},{"id":"https://openalex.org/C158207573","wikidata":"https://www.wikidata.org/wiki/Q5747224","display_name":"Heterogeneous network","level":4,"score":0.497052937746048},{"id":"https://openalex.org/C66204764","wikidata":"https://www.wikidata.org/wiki/Q219416","display_name":"Sustainability","level":2,"score":0.44815242290496826},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.4389106035232544},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.4365319609642029},{"id":"https://openalex.org/C129230348","wikidata":"https://www.wikidata.org/wiki/Q1140205","display_name":"Disaster recovery","level":2,"score":0.4200412333011627},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.4125615954399109},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.1888566017150879},{"id":"https://openalex.org/C136764020","wikidata":"https://www.wikidata.org/wiki/Q466","display_name":"World Wide Web","level":1,"score":0.08581021428108215},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.06870844960212708},{"id":"https://openalex.org/C199539241","wikidata":"https://www.wikidata.org/wiki/Q7748","display_name":"Law","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C17744445","wikidata":"https://www.wikidata.org/wiki/Q36442","display_name":"Political science","level":0,"score":0.0},{"id":"https://openalex.org/C18903297","wikidata":"https://www.wikidata.org/wiki/Q7150","display_name":"Ecology","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ict-dm.2015.7402059","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ict-dm.2015.7402059","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 2nd International Conference on Information and Communication Technologies for Disaster Management (ICT-DM)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":11,"referenced_works":["https://openalex.org/W1936269000","https://openalex.org/W1938020778","https://openalex.org/W1967490975","https://openalex.org/W2074084090","https://openalex.org/W2116432526","https://openalex.org/W2156639545","https://openalex.org/W4206890074","https://openalex.org/W6640488897","https://openalex.org/W6677762655","https://openalex.org/W6683109497","https://openalex.org/W6807618959"],"related_works":["https://openalex.org/W2982321410","https://openalex.org/W2392004567","https://openalex.org/W2940029036","https://openalex.org/W4388292429","https://openalex.org/W2756595502","https://openalex.org/W2046296964","https://openalex.org/W1990395098","https://openalex.org/W2805060255","https://openalex.org/W117756266","https://openalex.org/W2160089643"],"abstract_inverted_index":{"After":[0],"a":[1,15,23,69,76],"disaster,":[2],"much":[3],"of":[4],"infrastructure":[5],"is":[6],"no":[7],"longer":[8],"usable,":[9],"including":[10],"telecommunications.":[11],"The":[12],"hours":[13],"following":[14],"disaster":[16,77],"are":[17],"crucial.":[18],"Thus,":[19],"we":[20,60],"must":[21,42],"find":[22],"solution":[24,41,84],"to":[25,28,36,48,67,72,92],"allow":[26],"rescuers":[27,47],"communicate":[29],"with":[30],"the":[31,93],"survivors":[32],"or":[33],"at":[34],"least":[35],"locate":[37],"them.":[38],"This":[39,83],"telecommunication":[40],"also":[43],"enable":[44],"communication":[45],"between":[46],"facilitate":[49],"their":[50],"coordination":[51],"for":[52,80],"greater":[53],"speed":[54],"and":[55,89,96],"efficiency.":[56],"In":[57],"this":[58],"paper,":[59],"propose":[61],"an":[62],"energy-efficient":[63],"heterogeneous":[64],"wireless":[65],"network":[66],"help":[68],"rescue":[70],"team":[71],"organise":[73],"itself":[74],"in":[75],"relief":[78],"scenario":[79],"saving":[81],"lives.":[82],"can":[85],"be":[86],"deployed":[87],"rapidly":[88],"sustainably":[90],"thanks":[91],"dynamic":[94],"spectrum":[95],"energy":[97],"management.":[98]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
