{"id":"https://openalex.org/W2306394970","doi":"https://doi.org/10.1109/icsenst.2015.7438504","title":"Intelligent online sensor monitoring and fault alarm system in heating ventilation and air conditioning systems","display_name":"Intelligent online sensor monitoring and fault alarm system in heating ventilation and air conditioning systems","publication_year":2015,"publication_date":"2015-12-01","ids":{"openalex":"https://openalex.org/W2306394970","doi":"https://doi.org/10.1109/icsenst.2015.7438504","mag":"2306394970"},"language":"en","primary_location":{"id":"doi:10.1109/icsenst.2015.7438504","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icsenst.2015.7438504","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 9th International Conference on Sensing Technology (ICST)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101678990","display_name":"Ying Guo","orcid":"https://orcid.org/0000-0002-8678-1551"},"institutions":[{"id":"https://openalex.org/I1292875679","display_name":"Commonwealth Scientific and Industrial Research Organisation","ror":"https://ror.org/03qn8fb07","country_code":"AU","type":"funder","lineage":["https://openalex.org/I1292875679","https://openalex.org/I2801453606","https://openalex.org/I4387156119"]}],"countries":["AU"],"is_corresponding":true,"raw_author_name":"Ying Guo","raw_affiliation_strings":["Digital Productivity Flagship, The Commonwealth Scientific and Industrial Research Organisation, Marsfield, Australia"],"affiliations":[{"raw_affiliation_string":"Digital Productivity Flagship, The Commonwealth Scientific and Industrial Research Organisation, Marsfield, Australia","institution_ids":["https://openalex.org/I1292875679"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5111713767","display_name":"Josh Wall","orcid":null},"institutions":[{"id":"https://openalex.org/I1292875679","display_name":"Commonwealth Scientific and Industrial Research Organisation","ror":"https://ror.org/03qn8fb07","country_code":"AU","type":"funder","lineage":["https://openalex.org/I1292875679","https://openalex.org/I2801453606","https://openalex.org/I4387156119"]}],"countries":["AU"],"is_corresponding":false,"raw_author_name":"Josh Wall","raw_affiliation_strings":["Energy Flagship, The Commonwealth Scientific and Industrial Research Organisation, Mayfield West, NSW, Australia"],"affiliations":[{"raw_affiliation_string":"Energy Flagship, The Commonwealth Scientific and Industrial Research Organisation, Mayfield West, NSW, Australia","institution_ids":["https://openalex.org/I1292875679"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100326750","display_name":"Jiaming Li","orcid":"https://orcid.org/0000-0002-7953-7024"},"institutions":[{"id":"https://openalex.org/I1292875679","display_name":"Commonwealth Scientific and Industrial Research Organisation","ror":"https://ror.org/03qn8fb07","country_code":"AU","type":"funder","lineage":["https://openalex.org/I1292875679","https://openalex.org/I2801453606","https://openalex.org/I4387156119"]}],"countries":["AU"],"is_corresponding":false,"raw_author_name":"Jiaming Li","raw_affiliation_strings":["Digital Productivity Flagship, The Commonwealth Scientific and Industrial Research Organisation, Marsfield, Australia"],"affiliations":[{"raw_affiliation_string":"Digital Productivity Flagship, The Commonwealth Scientific and Industrial Research Organisation, Marsfield, Australia","institution_ids":["https://openalex.org/I1292875679"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5057011541","display_name":"Sam West","orcid":"https://orcid.org/0000-0002-2653-8816"},"institutions":[{"id":"https://openalex.org/I1292875679","display_name":"Commonwealth Scientific and Industrial Research Organisation","ror":"https://ror.org/03qn8fb07","country_code":"AU","type":"funder","lineage":["https://openalex.org/I1292875679","https://openalex.org/I2801453606","https://openalex.org/I4387156119"]}],"countries":["AU"],"is_corresponding":false,"raw_author_name":"Sam West","raw_affiliation_strings":["Energy Flagship, The Commonwealth Scientific and Industrial Research Organisation, Mayfield West, NSW, Australia"],"affiliations":[{"raw_affiliation_string":"Energy Flagship, The Commonwealth Scientific and Industrial Research Organisation, Mayfield West, NSW, Australia","institution_ids":["https://openalex.org/I1292875679"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5101678990"],"corresponding_institution_ids":["https://openalex.org/I1292875679"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.186288,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"603","issue":null,"first_page":"789","last_page":"794"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.9800000190734863,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11667","display_name":"Advanced Chemical Sensor Technologies","score":0.9739000201225281,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hvac","display_name":"HVAC","score":0.9617797136306763},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"Air conditioning","score":0.7347532510757446},{"id":"https://openalex.org/keywords/alarm","display_name":"ALARM","score":0.6443586349487305},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.6133080124855042},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.5693619251251221},{"id":"https://openalex.org/keywords/ventilation","display_name":"Ventilation (architecture)","score":0.5589606761932373},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.5084449052810669},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4752373695373535},{"id":"https://openalex.org/keywords/indoor-air-quality","display_name":"Indoor air quality","score":0.4522472321987152},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.3944116532802582},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.3765479326248169},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3572438359260559},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.224816232919693},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.13068729639053345}],"concepts":[{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.9617797136306763},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.7347532510757446},{"id":"https://openalex.org/C2779119184","wikidata":"https://www.wikidata.org/wiki/Q294350","display_name":"ALARM","level":2,"score":0.6443586349487305},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.6133080124855042},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5693619251251221},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.5589606761932373},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.5084449052810669},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4752373695373535},{"id":"https://openalex.org/C65469","wikidata":"https://www.wikidata.org/wiki/Q905504","display_name":"Indoor air quality","level":2,"score":0.4522472321987152},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.3944116532802582},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3765479326248169},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3572438359260559},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.224816232919693},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.13068729639053345},{"id":"https://openalex.org/C87717796","wikidata":"https://www.wikidata.org/wiki/Q146326","display_name":"Environmental engineering","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icsenst.2015.7438504","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icsenst.2015.7438504","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 9th International Conference on Sensing Technology (ICST)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.4699999988079071,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W251578582","https://openalex.org/W1012296217","https://openalex.org/W1994034588","https://openalex.org/W2000025671","https://openalex.org/W2007842565","https://openalex.org/W2014583082","https://openalex.org/W2030582429","https://openalex.org/W2035424738","https://openalex.org/W2050637698","https://openalex.org/W2171939393","https://openalex.org/W2980388055","https://openalex.org/W4236545528"],"related_works":["https://openalex.org/W2112866972","https://openalex.org/W4240233711","https://openalex.org/W2900606913","https://openalex.org/W4320003279","https://openalex.org/W2326910963","https://openalex.org/W3046823714","https://openalex.org/W2348218441","https://openalex.org/W1525696263","https://openalex.org/W3021806226","https://openalex.org/W2182087970"],"abstract_inverted_index":{"The":[0,83],"heating,":[1],"ventilation,":[2],"and":[3,14,64,92],"air":[4,17],"conditioning":[5],"(HVAC)":[6],"system":[7,44],"is":[8,86],"designed":[9],"to":[10,47,77],"provide":[11],"thermal":[12],"comfort":[13],"acceptable":[15],"indoor":[16],"quality.":[18],"A":[19],"variety":[20,55],"of":[21,53,56,99],"sensing":[22],"devices":[23],"(such":[24],"as":[25,68,70],"temperature,":[26],"humidity,":[27],"velocity,":[28],"or":[29],"pressure":[30],"sensors)":[31],"are":[32,101],"installed":[33],"in":[34,89],"the":[35,42,71,79],"HVAC":[36,43],"systems.":[37],"In":[38],"a":[39,54],"realistic":[40],"situation,":[41],"can":[45],"fail":[46],"satisfy":[48],"performance":[49],"expectations":[50],"envisioned":[51],"because":[52],"problems.":[57],"This":[58],"paper":[59],"presents":[60],"online":[61],"sensor":[62,73],"monitoring":[63],"fault":[65,80],"detection":[66,81],"techniques,":[67],"well":[69],"key":[72],"sets":[74],"selection":[75],"approach":[76],"optimise":[78],"results.":[82],"methodology":[84],"presented":[85],"also":[87],"implemented":[88],"commercial":[90],"buildings":[91],"experimental":[93],"results":[94],"show":[95],"that":[96],"different":[97],"types":[98],"faults":[100],"detected":[102],"successfully.":[103]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
