{"id":"https://openalex.org/W2065663016","doi":"https://doi.org/10.1109/icsenst.2013.6727633","title":"Ultrasonic range measurements on the human body","display_name":"Ultrasonic range measurements on the human body","publication_year":2013,"publication_date":"2013-12-01","ids":{"openalex":"https://openalex.org/W2065663016","doi":"https://doi.org/10.1109/icsenst.2013.6727633","mag":"2065663016"},"language":"en","primary_location":{"id":"doi:10.1109/icsenst.2013.6727633","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icsenst.2013.6727633","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 Seventh International Conference on Sensing Technology (ICST)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5033716406","display_name":"Dirk Weenk","orcid":null},"institutions":[{"id":"https://openalex.org/I94624287","display_name":"University of Twente","ror":"https://ror.org/006hf6230","country_code":"NL","type":"education","lineage":["https://openalex.org/I94624287"]}],"countries":["NL"],"is_corresponding":true,"raw_author_name":"D. Weenk","raw_affiliation_strings":["CTIT Centre for Telematics and Information Technology, University of Twente, Enschede, the Netherlands","MIRA Inst. for Biomed. Technol. & Tech. Med., Univ. of Twente, Enschede, Netherlands"],"affiliations":[{"raw_affiliation_string":"CTIT Centre for Telematics and Information Technology, University of Twente, Enschede, the Netherlands","institution_ids":["https://openalex.org/I94624287"]},{"raw_affiliation_string":"MIRA Inst. for Biomed. Technol. & Tech. Med., Univ. of Twente, Enschede, Netherlands","institution_ids":["https://openalex.org/I94624287"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5004668588","display_name":"B. J. F. van Beijnum","orcid":null},"institutions":[{"id":"https://openalex.org/I94624287","display_name":"University of Twente","ror":"https://ror.org/006hf6230","country_code":"NL","type":"education","lineage":["https://openalex.org/I94624287"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"B. J. F. van Beijnum","raw_affiliation_strings":["CTIT Centre for Telematics and Information Technology, University of Twente, Enschede, the Netherlands","MIRA Inst. for Biomed. Technol. & Tech. Med., Univ. of Twente, Enschede, Netherlands"],"affiliations":[{"raw_affiliation_string":"CTIT Centre for Telematics and Information Technology, University of Twente, Enschede, the Netherlands","institution_ids":["https://openalex.org/I94624287"]},{"raw_affiliation_string":"MIRA Inst. for Biomed. Technol. & Tech. Med., Univ. of Twente, Enschede, Netherlands","institution_ids":["https://openalex.org/I94624287"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5012348650","display_name":"Adriaan Droog","orcid":null},"institutions":[{"id":"https://openalex.org/I94624287","display_name":"University of Twente","ror":"https://ror.org/006hf6230","country_code":"NL","type":"education","lineage":["https://openalex.org/I94624287"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"A. Droog","raw_affiliation_strings":["MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschedc, the Netherlands","MIRA Inst. for Biomed. Technol. & Tech. Med., Univ. of Twente, Enschede, Netherlands"],"affiliations":[{"raw_affiliation_string":"MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschedc, the Netherlands","institution_ids":["https://openalex.org/I94624287"]},{"raw_affiliation_string":"MIRA Inst. for Biomed. Technol. & Tech. Med., Univ. of Twente, Enschede, Netherlands","institution_ids":["https://openalex.org/I94624287"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5012753135","display_name":"Hermie Hermens","orcid":"https://orcid.org/0000-0002-3065-3876"},"institutions":[{"id":"https://openalex.org/I94624287","display_name":"University of Twente","ror":"https://ror.org/006hf6230","country_code":"NL","type":"education","lineage":["https://openalex.org/I94624287"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"H. J. Hermens","raw_affiliation_strings":["CTIT Centre for Telematics and Information Technology, University of Twente, Enschede, the Netherlands","MIRA Inst. for Biomed. Technol. & Tech. Med., Univ. of Twente, Enschede, Netherlands"],"affiliations":[{"raw_affiliation_string":"CTIT Centre for Telematics and Information Technology, University of Twente, Enschede, the Netherlands","institution_ids":["https://openalex.org/I94624287"]},{"raw_affiliation_string":"MIRA Inst. for Biomed. Technol. & Tech. Med., Univ. of Twente, Enschede, Netherlands","institution_ids":["https://openalex.org/I94624287"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5080611863","display_name":"Petrus H. Veltink","orcid":"https://orcid.org/0000-0002-1796-9999"},"institutions":[{"id":"https://openalex.org/I94624287","display_name":"University of Twente","ror":"https://ror.org/006hf6230","country_code":"NL","type":"education","lineage":["https://openalex.org/I94624287"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"P. H. Veltink","raw_affiliation_strings":["MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschedc, the Netherlands","MIRA Inst. for Biomed. Technol. & Tech. Med., Univ. of Twente, Enschede, Netherlands"],"affiliations":[{"raw_affiliation_string":"MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschedc, the Netherlands","institution_ids":["https://openalex.org/I94624287"]},{"raw_affiliation_string":"MIRA Inst. for Biomed. Technol. & Tech. Med., Univ. of Twente, Enschede, Netherlands","institution_ids":["https://openalex.org/I94624287"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5033716406"],"corresponding_institution_ids":["https://openalex.org/I94624287"],"apc_list":null,"apc_paid":null,"fwci":1.2311,"has_fulltext":false,"cited_by_count":11,"citation_normalized_percentile":{"value":0.79408209,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"151","last_page":"156"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10114","display_name":"Balance, Gait, and Falls Prevention","score":0.9905999898910522,"subfield":{"id":"https://openalex.org/subfields/3612","display_name":"Physical Therapy, Sports Therapy and Rehabilitation"},"field":{"id":"https://openalex.org/fields/36","display_name":"Health Professions"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10924","display_name":"Cardiovascular Health and Disease Prevention","score":0.988099992275238,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ultrasonic-sensor","display_name":"Ultrasonic sensor","score":0.6679155230522156},{"id":"https://openalex.org/keywords/range","display_name":"Range (aeronautics)","score":0.499159574508667},{"id":"https://openalex.org/keywords/ultrasonic-imaging","display_name":"Ultrasonic imaging","score":0.45020997524261475},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.4215720593929291},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3598918914794922},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.3143491744995117},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.16688278317451477}],"concepts":[{"id":"https://openalex.org/C81288441","wikidata":"https://www.wikidata.org/wiki/Q20736125","display_name":"Ultrasonic sensor","level":2,"score":0.6679155230522156},{"id":"https://openalex.org/C204323151","wikidata":"https://www.wikidata.org/wiki/Q905424","display_name":"Range (aeronautics)","level":2,"score":0.499159574508667},{"id":"https://openalex.org/C2989478337","wikidata":"https://www.wikidata.org/wiki/Q234904","display_name":"Ultrasonic imaging","level":3,"score":0.45020997524261475},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.4215720593929291},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3598918914794922},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.3143491744995117},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.16688278317451477},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/icsenst.2013.6727633","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icsenst.2013.6727633","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 Seventh International Conference on Sensing Technology (ICST)","raw_type":"proceedings-article"},{"id":"pmh:oai:ris.utwente.nl:openaire_cris_publications/e3ada709-ac64-4c54-8faa-45f7fca80c9c","is_oa":false,"landing_page_url":"https://research.utwente.nl/en/publications/e3ada709-ac64-4c54-8faa-45f7fca80c9c","pdf_url":null,"source":{"id":"https://openalex.org/S4406922991","display_name":"University of Twente Research Information","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Weenk, D, van Beijnum, B J F, Droog, A, Hermens, H J & Veltink, P H 2013, Ultrasonic range measurements on the human body. in Seventh International Conference on Sensing Technology, ICST 2013. IEEE, USA, pp. 151-156, 7th International Conference on Sensing Technology, ICST 2013, Wellington, New Zealand, 3/12/13. https://doi.org/10.1109/ICSensT.2013.6727633","raw_type":"info:eu-repo/semantics/publishedVersion"},{"id":"pmh:oai:ris.utwente.nl:publications/e3ada709-ac64-4c54-8faa-45f7fca80c9c","is_oa":false,"landing_page_url":"http://eprints.eemcs.utwente.nl/secure2/24363/01/1569816249.pdf","pdf_url":null,"source":{"id":"https://openalex.org/S4406922991","display_name":"University of Twente Research Information","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Weenk , D , van Beijnum , B J F , Droog , A , Hermens , H J &amp; Veltink , P H 2013 , Ultrasonic range measurements on the human body . in Seventh International Conference on Sensing Technology, ICST 2013 . IEEE , USA , pp. 151-156 , 7th International Conference on Sensing Technology, ICST 2013 , Wellington , New Zealand , 3/12/13 . https://doi.org/10.1109/ICSensT.2013.6727633","raw_type":"contributionToPeriodical"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":15,"referenced_works":["https://openalex.org/W323911834","https://openalex.org/W575841261","https://openalex.org/W1215311137","https://openalex.org/W1597887109","https://openalex.org/W1603032940","https://openalex.org/W2009133028","https://openalex.org/W2020671828","https://openalex.org/W2068222432","https://openalex.org/W2076590703","https://openalex.org/W2086564413","https://openalex.org/W2090972754","https://openalex.org/W2135842230","https://openalex.org/W2136853899","https://openalex.org/W6636147375","https://openalex.org/W6680314441"],"related_works":["https://openalex.org/W2380594826","https://openalex.org/W2031629218","https://openalex.org/W4238525810","https://openalex.org/W4247875078","https://openalex.org/W4238161731","https://openalex.org/W4256618856","https://openalex.org/W2377597505","https://openalex.org/W2366714167","https://openalex.org/W1976507804","https://openalex.org/W4245361752"],"abstract_inverted_index":{"Ambulatory":[0],"range":[1,81],"estimation":[2],"on":[3,33,51],"the":[4,10,13,34,46,52,68,77,80,98,104],"human":[5,35],"body":[6,36],"is":[7,37,48,71,112],"important":[8],"for":[9,30,76],"assessment":[11],"of":[12,15,54,67,79],"performance":[14],"upper-":[16],"and":[17,39,56,107],"lower":[18],"limb":[19],"tasks":[20],"outside":[21],"a":[22,74,90],"laboratory.":[23],"In":[24],"this":[25],"paper":[26],"an":[27,59,108],"ultrasound":[28,105],"sensor":[29,106],"estimating":[31],"ranges":[32],"presented":[38],"validated":[40],"during":[41],"gait.":[42],"The":[43,62],"distance":[44,87,101],"between":[45,103],"feet":[47],"estimated":[49],"based":[50],"time":[53],"flight":[55],"compared":[57],"to":[58,64,92],"optical":[60,109],"reference.":[61],"signal":[63,70,91],"noise":[65,93],"ratio":[66,94],"received":[69],"used":[72],"as":[73],"measure":[75],"uncertainty":[78],"estimate.":[82],"For":[83],"example":[84],"when":[85],"rejecting":[86],"estimates":[88],"with":[89],"smaller":[95],"than":[96],"5,":[97],"mean":[99],"absolute":[100],"difference":[102],"reference":[110],"system":[111],"7.0":[113],"mm":[114],"(sd":[115],"7.1":[116],"mm)":[117],"over":[118],"six":[119],"walking":[120],"trials.":[121]},"counts_by_year":[{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":2},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":2},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":2}],"updated_date":"2026-04-04T16:13:02.066488","created_date":"2025-10-10T00:00:00"}
