{"id":"https://openalex.org/W2907818895","doi":"https://doi.org/10.1109/icsens.2018.8589856","title":"Ultrasound Based Respiratory Monitoring Evaluation Under Human Body Motions","display_name":"Ultrasound Based Respiratory Monitoring Evaluation Under Human Body Motions","publication_year":2018,"publication_date":"2018-10-01","ids":{"openalex":"https://openalex.org/W2907818895","doi":"https://doi.org/10.1109/icsens.2018.8589856","mag":"2907818895"},"language":"en","primary_location":{"id":"doi:10.1109/icsens.2018.8589856","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icsens.2018.8589856","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE SENSORS","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5049049633","display_name":"Amirhossein Shahshahani","orcid":"https://orcid.org/0000-0002-4239-9262"},"institutions":[{"id":"https://openalex.org/I5023651","display_name":"McGill University","ror":"https://ror.org/01pxwe438","country_code":"CA","type":"education","lineage":["https://openalex.org/I5023651"]}],"countries":["CA"],"is_corresponding":true,"raw_author_name":"Amirhossein Shahshahani","raw_affiliation_strings":["Department of Electrical and Computer Engineering, McGill university, Montreal, Canada"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, McGill university, Montreal, Canada","institution_ids":["https://openalex.org/I5023651"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5004729856","display_name":"Sharmistha Bhadra","orcid":"https://orcid.org/0000-0002-2195-8977"},"institutions":[{"id":"https://openalex.org/I5023651","display_name":"McGill University","ror":"https://ror.org/01pxwe438","country_code":"CA","type":"education","lineage":["https://openalex.org/I5023651"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Sharmistha Bhadra","raw_affiliation_strings":["Department of Electrical and Computer Engineering, McGill university, Montreal, Canada"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, McGill university, Montreal, Canada","institution_ids":["https://openalex.org/I5023651"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5062514163","display_name":"\u017deljko \u017dili\u0107","orcid":"https://orcid.org/0000-0002-6887-3911"},"institutions":[{"id":"https://openalex.org/I5023651","display_name":"McGill University","ror":"https://ror.org/01pxwe438","country_code":"CA","type":"education","lineage":["https://openalex.org/I5023651"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Zeljko Zilic","raw_affiliation_strings":["Department of Electrical and Computer Engineering, McGill university, Montreal, Canada"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, McGill university, Montreal, Canada","institution_ids":["https://openalex.org/I5023651"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5049049633"],"corresponding_institution_ids":["https://openalex.org/I5023651"],"apc_list":null,"apc_paid":null,"fwci":0.2221,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.54748844,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10322","display_name":"Respiratory Support and Mechanisms","score":0.9959999918937683,"subfield":{"id":"https://openalex.org/subfields/2740","display_name":"Pulmonary and Respiratory Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11700","display_name":"Hemodynamic Monitoring and Therapy","score":0.9922000169754028,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/spirometer","display_name":"Spirometer","score":0.7655090093612671},{"id":"https://openalex.org/keywords/photoplethysmogram","display_name":"Photoplethysmogram","score":0.6347867846488953},{"id":"https://openalex.org/keywords/diaphragm","display_name":"Diaphragm (acoustics)","score":0.6324595212936401},{"id":"https://openalex.org/keywords/ultrasound","display_name":"Ultrasound","score":0.6076829433441162},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5508803725242615},{"id":"https://openalex.org/keywords/robustness","display_name":"Robustness (evolution)","score":0.5365943908691406},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.5163451433181763},{"id":"https://openalex.org/keywords/diaphragmatic-breathing","display_name":"Diaphragmatic breathing","score":0.5013744831085205},{"id":"https://openalex.org/keywords/match-moving","display_name":"Match moving","score":0.44125279784202576},{"id":"https://openalex.org/keywords/breathing","display_name":"Breathing","score":0.4220300316810608},{"id":"https://openalex.org/keywords/remote-patient-monitoring","display_name":"Remote patient monitoring","score":0.4174131751060486},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.4147277772426605},{"id":"https://openalex.org/keywords/computer-vision","display_name":"Computer vision","score":0.3957299292087555},{"id":"https://openalex.org/keywords/vibration","display_name":"Vibration","score":0.27286630868911743},{"id":"https://openalex.org/keywords/motion","display_name":"Motion (physics)","score":0.23400434851646423},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.21653589606285095},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.16021904349327087},{"id":"https://openalex.org/keywords/radiology","display_name":"Radiology","score":0.14451098442077637},{"id":"https://openalex.org/keywords/anatomy","display_name":"Anatomy","score":0.14345142245292664},{"id":"https://openalex.org/keywords/surgery","display_name":"Surgery","score":0.13045525550842285},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.11342406272888184}],"concepts":[{"id":"https://openalex.org/C2776727875","wikidata":"https://www.wikidata.org/wiki/Q1344868","display_name":"Spirometer","level":5,"score":0.7655090093612671},{"id":"https://openalex.org/C116390426","wikidata":"https://www.wikidata.org/wiki/Q7187885","display_name":"Photoplethysmogram","level":3,"score":0.6347867846488953},{"id":"https://openalex.org/C164292776","wikidata":"https://www.wikidata.org/wiki/Q5271779","display_name":"Diaphragm (acoustics)","level":3,"score":0.6324595212936401},{"id":"https://openalex.org/C143753070","wikidata":"https://www.wikidata.org/wiki/Q162564","display_name":"Ultrasound","level":2,"score":0.6076829433441162},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5508803725242615},{"id":"https://openalex.org/C63479239","wikidata":"https://www.wikidata.org/wiki/Q7353546","display_name":"Robustness (evolution)","level":3,"score":0.5365943908691406},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.5163451433181763},{"id":"https://openalex.org/C20463939","wikidata":"https://www.wikidata.org/wiki/Q811123","display_name":"Diaphragmatic breathing","level":3,"score":0.5013744831085205},{"id":"https://openalex.org/C95020103","wikidata":"https://www.wikidata.org/wiki/Q1813492","display_name":"Match moving","level":3,"score":0.44125279784202576},{"id":"https://openalex.org/C39300077","wikidata":"https://www.wikidata.org/wiki/Q9530","display_name":"Breathing","level":2,"score":0.4220300316810608},{"id":"https://openalex.org/C175079658","wikidata":"https://www.wikidata.org/wiki/Q7312165","display_name":"Remote patient monitoring","level":2,"score":0.4174131751060486},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.4147277772426605},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.3957299292087555},{"id":"https://openalex.org/C198394728","wikidata":"https://www.wikidata.org/wiki/Q3695508","display_name":"Vibration","level":2,"score":0.27286630868911743},{"id":"https://openalex.org/C104114177","wikidata":"https://www.wikidata.org/wiki/Q79782","display_name":"Motion (physics)","level":2,"score":0.23400434851646423},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.21653589606285095},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.16021904349327087},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.14451098442077637},{"id":"https://openalex.org/C105702510","wikidata":"https://www.wikidata.org/wiki/Q514","display_name":"Anatomy","level":1,"score":0.14345142245292664},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.13045525550842285},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.11342406272888184},{"id":"https://openalex.org/C204787440","wikidata":"https://www.wikidata.org/wiki/Q188504","display_name":"Alternative medicine","level":2,"score":0.0},{"id":"https://openalex.org/C106131492","wikidata":"https://www.wikidata.org/wiki/Q3072260","display_name":"Filter (signal processing)","level":2,"score":0.0},{"id":"https://openalex.org/C2780769369","wikidata":"https://www.wikidata.org/wiki/Q4375","display_name":"Bronchoconstriction","level":3,"score":0.0},{"id":"https://openalex.org/C142724271","wikidata":"https://www.wikidata.org/wiki/Q7208","display_name":"Pathology","level":1,"score":0.0},{"id":"https://openalex.org/C2781142857","wikidata":"https://www.wikidata.org/wiki/Q5420174","display_name":"Exhaled nitric oxide","level":4,"score":0.0},{"id":"https://openalex.org/C105922876","wikidata":"https://www.wikidata.org/wiki/Q1423981","display_name":"Airway","level":2,"score":0.0},{"id":"https://openalex.org/C104317684","wikidata":"https://www.wikidata.org/wiki/Q7187","display_name":"Gene","level":2,"score":0.0},{"id":"https://openalex.org/C55493867","wikidata":"https://www.wikidata.org/wiki/Q7094","display_name":"Biochemistry","level":1,"score":0.0},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icsens.2018.8589856","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icsens.2018.8589856","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE SENSORS","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W1653832639","https://openalex.org/W1993871899","https://openalex.org/W2018160045","https://openalex.org/W2093419936","https://openalex.org/W2095970154","https://openalex.org/W2098273140","https://openalex.org/W2117749765","https://openalex.org/W2131496831","https://openalex.org/W2151674612","https://openalex.org/W2151748668","https://openalex.org/W2297268244","https://openalex.org/W2315157821","https://openalex.org/W2743573221","https://openalex.org/W2886153089"],"related_works":["https://openalex.org/W2732360296","https://openalex.org/W3089003976","https://openalex.org/W1994871954","https://openalex.org/W4297152434","https://openalex.org/W2184912121","https://openalex.org/W2981709955","https://openalex.org/W4389542338","https://openalex.org/W2115667775","https://openalex.org/W1924129618","https://openalex.org/W2754819597"],"abstract_inverted_index":{"A":[0],"novel":[1],"pulmonary":[2],"monitoring":[3,40],"system":[4,22,117,131],"based":[5],"on":[6],"diaphragm":[7,109],"wall":[8],"motion":[9,110,122],"tracking":[10,111],"is":[11,53,118],"proposed.":[12],"Diaphragm":[13],"motions":[14],"are":[15,62,89],"measured":[16],"by":[17],"a":[18,65,103],"designed":[19],"ultrasound":[20,26,51],"sensory":[21],"with":[23,136],"only":[24],"one":[25],"PZT5":[27],"piezo":[28],"transducer.":[29],"We":[30],"evaluate":[31,74,97],"the":[32,41,56,98,108,113,116,129],"accuracy":[33],"and":[34,44,76,140,144],"robustness":[35],"of":[36,58,100,112,142],"this":[37,70,85],"technique":[38],"in":[39,55,84,91,102,146],"diaphragmatic":[42],"function":[43],"its":[45],"contribution":[46],"to":[47,64,96,107,121],"respiratory":[48],"workload.":[49],"The":[50],"sensor":[52],"placed":[54],"zone":[57],"apposition":[59],"(ZOA).":[60],"Measurements":[61],"referenced":[63],"SPR-BTA":[66],"commercial":[67],"spirometer.":[68],"In":[69],"study,":[71],"we":[72],"also":[73],"inertial":[75],"photoplethysmography":[77],"(PPG)":[78],"sensors":[79,101],"as":[80],"two":[81],"alternative":[82],"methods":[83],"area.":[86],"All":[87],"tests":[88,135],"done":[90],"non-stationary":[92],"human":[93],"body":[94],"situation":[95],"usage":[99],"real":[104],"life.":[105],"According":[106],"proposed":[114,130],"method,":[115],"extremely":[119],"insensitive":[120],"artifacts.":[123],"Promising":[124],"results":[125],"were":[126],"obtained":[127],"for":[128],"from":[132],"four":[133],"different":[134],"an":[137],"average":[138],"sensitivity":[139],"specificity":[141],"88%":[143],"73.5%":[145],"respiration":[147],"detection,":[148],"respectively.":[149]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":1}],"updated_date":"2026-03-25T13:04:00.132906","created_date":"2025-10-10T00:00:00"}
