{"id":"https://openalex.org/W3207001707","doi":"https://doi.org/10.1109/icra48506.2021.9561072","title":"Shape Sensor Using Magnetic Induction with Frequency Sweeping for Medical Catheters","display_name":"Shape Sensor Using Magnetic Induction with Frequency Sweeping for Medical Catheters","publication_year":2021,"publication_date":"2021-05-30","ids":{"openalex":"https://openalex.org/W3207001707","doi":"https://doi.org/10.1109/icra48506.2021.9561072","mag":"3207001707"},"language":"en","primary_location":{"id":"doi:10.1109/icra48506.2021.9561072","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icra48506.2021.9561072","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 IEEE International Conference on Robotics and Automation (ICRA)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5061326684","display_name":"Jiyun Jeon","orcid":"https://orcid.org/0000-0001-8024-5099"},"institutions":[{"id":"https://openalex.org/I58716616","display_name":"Korea Institute of Science and Technology","ror":"https://ror.org/05kzfa883","country_code":"KR","type":"facility","lineage":["https://openalex.org/I27494661","https://openalex.org/I2801339556","https://openalex.org/I2801339556","https://openalex.org/I4210144908","https://openalex.org/I4387152098","https://openalex.org/I4387152098","https://openalex.org/I58716616"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Jiyun Jeon","raw_affiliation_strings":["Center for Healthcare Robotics, Korea Institute Science and Technology (KIST), Seoul, Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Center for Healthcare Robotics, Korea Institute Science and Technology (KIST), Seoul, Korea","institution_ids":["https://openalex.org/I58716616"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5077591125","display_name":"Chunwoo Kim","orcid":"https://orcid.org/0000-0002-3167-9648"},"institutions":[{"id":"https://openalex.org/I58716616","display_name":"Korea Institute of Science and Technology","ror":"https://ror.org/05kzfa883","country_code":"KR","type":"facility","lineage":["https://openalex.org/I27494661","https://openalex.org/I2801339556","https://openalex.org/I2801339556","https://openalex.org/I4210144908","https://openalex.org/I4387152098","https://openalex.org/I4387152098","https://openalex.org/I58716616"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Chunwoo Kim","raw_affiliation_strings":["Center for Healthcare Robotics, Korea Institute Science and Technology (KIST), Seoul, Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Center for Healthcare Robotics, Korea Institute Science and Technology (KIST), Seoul, Korea","institution_ids":["https://openalex.org/I58716616"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.3051,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.57456588,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"7137","last_page":"7143"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10205","display_name":"Advanced Fiber Optic Sensors","score":0.9976000189781189,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10205","display_name":"Advanced Fiber Optic Sensors","score":0.9976000189781189,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11472","display_name":"Analytical Chemistry and Sensors","score":0.9955999851226807,"subfield":{"id":"https://openalex.org/subfields/1502","display_name":"Bioengineering"},"field":{"id":"https://openalex.org/fields/15","display_name":"Chemical Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12537","display_name":"Flow Measurement and Analysis","score":0.9954000115394592,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electromagnetic-coil","display_name":"Electromagnetic coil","score":0.7018240690231323},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.7007326483726501},{"id":"https://openalex.org/keywords/exciter","display_name":"Exciter","score":0.6665304899215698},{"id":"https://openalex.org/keywords/bending","display_name":"Bending","score":0.45645496249198914},{"id":"https://openalex.org/keywords/filter","display_name":"Filter (signal processing)","score":0.44178542494773865},{"id":"https://openalex.org/keywords/electromagnetic-induction","display_name":"Electromagnetic induction","score":0.4241126477718353},{"id":"https://openalex.org/keywords/induction-coil","display_name":"Induction coil","score":0.42343592643737793},{"id":"https://openalex.org/keywords/inductance","display_name":"Inductance","score":0.4127809405326843},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3774496912956238},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.33975106477737427},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.3392341732978821},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3243066668510437},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.31010687351226807},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.15373754501342773},{"id":"https://openalex.org/keywords/structural-engineering","display_name":"Structural engineering","score":0.11819064617156982}],"concepts":[{"id":"https://openalex.org/C30403606","wikidata":"https://www.wikidata.org/wiki/Q2981904","display_name":"Electromagnetic coil","level":2,"score":0.7018240690231323},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.7007326483726501},{"id":"https://openalex.org/C2777149130","wikidata":"https://www.wikidata.org/wiki/Q445199","display_name":"Exciter","level":2,"score":0.6665304899215698},{"id":"https://openalex.org/C87210426","wikidata":"https://www.wikidata.org/wiki/Q1072476","display_name":"Bending","level":2,"score":0.45645496249198914},{"id":"https://openalex.org/C106131492","wikidata":"https://www.wikidata.org/wiki/Q3072260","display_name":"Filter (signal processing)","level":2,"score":0.44178542494773865},{"id":"https://openalex.org/C102130693","wikidata":"https://www.wikidata.org/wiki/Q988780","display_name":"Electromagnetic induction","level":3,"score":0.4241126477718353},{"id":"https://openalex.org/C102998134","wikidata":"https://www.wikidata.org/wiki/Q1417360","display_name":"Induction coil","level":3,"score":0.42343592643737793},{"id":"https://openalex.org/C29210110","wikidata":"https://www.wikidata.org/wiki/Q177897","display_name":"Inductance","level":3,"score":0.4127809405326843},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3774496912956238},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.33975106477737427},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.3392341732978821},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3243066668510437},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.31010687351226807},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.15373754501342773},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.11819064617156982},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icra48506.2021.9561072","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icra48506.2021.9561072","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 IEEE International Conference on Robotics and Automation (ICRA)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W1590656837","https://openalex.org/W1967392346","https://openalex.org/W2013681472","https://openalex.org/W2096847711","https://openalex.org/W2102994281","https://openalex.org/W2140637004","https://openalex.org/W2147404381","https://openalex.org/W2165279661","https://openalex.org/W2293626157","https://openalex.org/W2318352171","https://openalex.org/W2329035258","https://openalex.org/W2544641369","https://openalex.org/W2758838340","https://openalex.org/W2802667822","https://openalex.org/W2884823105","https://openalex.org/W3089862848"],"related_works":["https://openalex.org/W793632939","https://openalex.org/W3117325437","https://openalex.org/W2072369510","https://openalex.org/W4367837086","https://openalex.org/W2375000822","https://openalex.org/W1691817568","https://openalex.org/W2581515454","https://openalex.org/W2179468187","https://openalex.org/W2393870543","https://openalex.org/W4234445710"],"abstract_inverted_index":{"Shape":[0],"sensors":[1,115],"are":[2],"important":[3],"for":[4],"safer":[5],"and":[6,82,103,133,139],"more":[7],"dexterous":[8],"manipulation":[9],"of":[10,28,43,51,80,90,100,149],"the":[11,15,26,33,37,41,44,48,57,61,88,98,101,110,137,142],"medical":[12],"catheters.":[13],"Among":[14],"electromagnetic":[16],"based":[17],"shape":[18,23,76,148],"sensors,":[19],"a":[20,29,52,124,147,150],"voice":[21,53,74],"coil":[22,75],"sensor":[24,77,102,143],"measures":[25],"variation":[27],"mutual":[30],"inductance":[31],"between":[32],"coils":[34,93],"placed":[35,116,152],"along":[36],"tube":[38],"due":[39],"to":[40,47,96,108],"bending":[42,89],"tube.":[45],"Owing":[46],"design":[49],"flexibility":[50],"coil,":[54],"it":[55],"offers":[56],"small":[58],"size":[59],"without":[60],"external":[62],"magnetic":[63],"field":[64],"generator":[65],"outside":[66],"patient":[67],"body.":[68],"This":[69],"paper":[70],"presents":[71],"an":[72,91],"improved":[73],"in":[78,117],"terms":[79],"modeling":[81],"measurement.":[83],"Analytic":[84],"model":[85],"that":[86,141],"incorporates":[87],"exciter":[92],"is":[94,106],"used":[95],"improve":[97],"accuracy":[99],"band-pass":[104],"filter":[105],"applied":[107],"simplify":[109],"measurements.":[111],"Bending":[112],"angle":[113],"from":[114,127],"multiple":[118],"locations":[119],"can":[120,145],"be":[121],"measured":[122],"through":[123,153],"single":[125],"channel":[126],"frequency":[128],"sweep":[129],"input.":[130],"The":[131],"simulation":[132],"experimental":[134],"results":[135],"verify":[136],"improvement":[138],"demonstrate":[140],"system":[144],"reconstruct":[146],"catheter":[151],"larynx.":[154]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2022,"cited_by_count":2}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
