{"id":"https://openalex.org/W2117336546","doi":"https://doi.org/10.1109/icra.2011.5979687","title":"Fault-tolerant control of robot servomotors","display_name":"Fault-tolerant control of robot servomotors","publication_year":2011,"publication_date":"2011-05-01","ids":{"openalex":"https://openalex.org/W2117336546","doi":"https://doi.org/10.1109/icra.2011.5979687","mag":"2117336546"},"language":"en","primary_location":{"id":"doi:10.1109/icra.2011.5979687","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icra.2011.5979687","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 IEEE International Conference on Robotics and Automation","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5000948875","display_name":"Farhad Aghili","orcid":"https://orcid.org/0000-0002-2059-0226"},"institutions":[{"id":"https://openalex.org/I2800055578","display_name":"Canadian Space Agency","ror":"https://ror.org/03a1gte98","country_code":"CA","type":"government","lineage":["https://openalex.org/I2800055578"]}],"countries":["CA"],"is_corresponding":true,"raw_author_name":"Farhad Aghili","raw_affiliation_strings":["Canadian Space Agency, Saint-Hubert, QUE, Canada","Canadian Space Agency, Saint-Hubert, Quebec J3Y     8Y9, Canada"],"affiliations":[{"raw_affiliation_string":"Canadian Space Agency, Saint-Hubert, QUE, Canada","institution_ids":["https://openalex.org/I2800055578"]},{"raw_affiliation_string":"Canadian Space Agency, Saint-Hubert, Quebec J3Y     8Y9, Canada","institution_ids":["https://openalex.org/I2800055578"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5000948875"],"corresponding_institution_ids":["https://openalex.org/I2800055578"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.14396316,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"2757","last_page":"2763"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9864000082015991,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9864000082015991,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10504","display_name":"Sensorless Control of Electric Motors","score":0.9828000068664551,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9768000245094299,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.7729964256286621},{"id":"https://openalex.org/keywords/torque","display_name":"Torque","score":0.6221533417701721},{"id":"https://openalex.org/keywords/torque-ripple","display_name":"Torque ripple","score":0.5404605865478516},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4943056106567383},{"id":"https://openalex.org/keywords/servomotor","display_name":"Servomotor","score":0.47062137722969055},{"id":"https://openalex.org/keywords/harmonics","display_name":"Harmonics","score":0.44303205609321594},{"id":"https://openalex.org/keywords/waveform","display_name":"Waveform","score":0.428178071975708},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.419864684343338},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.37111860513687134},{"id":"https://openalex.org/keywords/direct-torque-control","display_name":"Direct torque control","score":0.34378522634506226},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.33958375453948975},{"id":"https://openalex.org/keywords/induction-motor","display_name":"Induction motor","score":0.3115598261356354},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.261574923992157},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.1528969407081604}],"concepts":[{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.7729964256286621},{"id":"https://openalex.org/C144171764","wikidata":"https://www.wikidata.org/wiki/Q48103","display_name":"Torque","level":2,"score":0.6221533417701721},{"id":"https://openalex.org/C2779675184","wikidata":"https://www.wikidata.org/wiki/Q7826797","display_name":"Torque ripple","level":5,"score":0.5404605865478516},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4943056106567383},{"id":"https://openalex.org/C109441226","wikidata":"https://www.wikidata.org/wiki/Q1137255","display_name":"Servomotor","level":2,"score":0.47062137722969055},{"id":"https://openalex.org/C188414643","wikidata":"https://www.wikidata.org/wiki/Q3001183","display_name":"Harmonics","level":3,"score":0.44303205609321594},{"id":"https://openalex.org/C197424946","wikidata":"https://www.wikidata.org/wiki/Q1165717","display_name":"Waveform","level":3,"score":0.428178071975708},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.419864684343338},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.37111860513687134},{"id":"https://openalex.org/C109871850","wikidata":"https://www.wikidata.org/wiki/Q1227571","display_name":"Direct torque control","level":4,"score":0.34378522634506226},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.33958375453948975},{"id":"https://openalex.org/C80962145","wikidata":"https://www.wikidata.org/wiki/Q207450","display_name":"Induction motor","level":3,"score":0.3115598261356354},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.261574923992157},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.1528969407081604},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icra.2011.5979687","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icra.2011.5979687","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 IEEE International Conference on Robotics and Automation","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8600000143051147,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":22,"referenced_works":["https://openalex.org/W1573754311","https://openalex.org/W1942690975","https://openalex.org/W2024687646","https://openalex.org/W2025743451","https://openalex.org/W2053505915","https://openalex.org/W2080703475","https://openalex.org/W2085621477","https://openalex.org/W2105385264","https://openalex.org/W2131672614","https://openalex.org/W2132135113","https://openalex.org/W2137751017","https://openalex.org/W2138292058","https://openalex.org/W2145166323","https://openalex.org/W2151375007","https://openalex.org/W2161086413","https://openalex.org/W2163353309","https://openalex.org/W2164804984","https://openalex.org/W2170133847","https://openalex.org/W2488793338","https://openalex.org/W2798766386","https://openalex.org/W4396738453","https://openalex.org/W6671761749"],"related_works":["https://openalex.org/W2121571705","https://openalex.org/W2183662634","https://openalex.org/W3118123443","https://openalex.org/W4321063092","https://openalex.org/W2379878679","https://openalex.org/W2349217415","https://openalex.org/W2594177041","https://openalex.org/W2923888187","https://openalex.org/W2345244343","https://openalex.org/W2011341094"],"abstract_inverted_index":{"The":[0,72,91],"servomotors":[1],"used":[2],"in":[3,14],"the":[4,78,83,88,97,100,108,112,120,137,144,152,156,166,169,182,186],"joints":[5],"of":[6,11,25,35,68,82,99,103,111,136,168,184],"a":[7,12,36,42,104,178],"manipulator":[8],"or":[9,33],"wheels":[10],"rover":[13],"high":[15],"risk":[16],"applications,":[17,21],"such":[18],"as":[19,125],"space":[20],"should":[22],"be":[23],"capable":[24],"continued":[26],"functional":[27],"operation":[28],"even":[29,65],"if":[30,66],"insulation":[31],"failure":[32,180],"open-circuit":[34],"winding":[37],"occur.":[38],"This":[39],"paper":[40],"presents":[41],"fault-tolerant":[43],"(FT)":[44],"torque":[45,55,124,175],"con":[46],"troller":[47],"for":[48,160],"brushless":[49],"motors":[50],"that":[51,119],"can":[52],"maintain":[53],"accurate":[54],"production":[56],"with":[57],"minimum":[58],"power":[59,129,188],"dissipation":[60],"subject":[61,131],"to":[62,132,143,172],"current":[63,134,138],"limitations":[64],"one":[67],"motor":[69,84,121],"phases":[70,114],"fails.":[71],"controller":[73,171],"is":[74,94,148],"developed":[75],"based":[76],"on":[77],"Fourier":[79],"series":[80],"model":[81],"back-EMF":[85],"waveform":[86],"and":[87],"cogging":[89],"torque.":[90],"faulty":[92],"phase":[93,109,179],"detected":[95],"from":[96],"covariance":[98],"estimation":[101],"error":[102],"voltage":[105],"observer.":[106],"Subsequently,":[107],"currents":[110],"remaining":[113],"are":[115],"optimally":[116],"reshaped":[117],"so":[118],"accurately":[122],"generates":[123],"requested":[126],"while":[127],"minimizing":[128],"loss":[130,189],"maximum":[133],"limitation":[135],"amplifiers.":[139],"A":[140],"closed-form":[141],"solution":[142],"optimization":[145],"programming":[146],"problem":[147],"found":[149],"by":[150,190],"using":[151],"Kuhn-Tucker":[153],"theorem;":[154],"rendering":[155],"control":[157],"approach":[158],"suitable":[159],"real-time":[161],"implementation.":[162],"Experimental":[163],"results":[164],"illustrate":[165],"capability":[167],"FT":[170],"achieve":[173],"ripple-free":[174],"performance":[176],"during":[177],"at":[181],"expenses":[183],"increasing":[185],"mean":[187],"28%.":[191]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
