{"id":"https://openalex.org/W2970923635","doi":"https://doi.org/10.1109/icphm.2019.8819412","title":"Faults Analysis of Double Water Inner Cooled Synchronous Machines","display_name":"Faults Analysis of Double Water Inner Cooled Synchronous Machines","publication_year":2019,"publication_date":"2019-06-01","ids":{"openalex":"https://openalex.org/W2970923635","doi":"https://doi.org/10.1109/icphm.2019.8819412","mag":"2970923635"},"language":"en","primary_location":{"id":"doi:10.1109/icphm.2019.8819412","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icphm.2019.8819412","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 IEEE International Conference on Prognostics and Health Management (ICPHM)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5054332012","display_name":"Andong Wang","orcid":"https://orcid.org/0000-0001-9446-1294"},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Andong Wang","raw_affiliation_strings":["State Grid Shandong Electric Power Research Institute, Jinan, China"],"affiliations":[{"raw_affiliation_string":"State Grid Shandong Electric Power Research Institute, Jinan, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100623232","display_name":"Junqing Li","orcid":"https://orcid.org/0000-0002-6021-3038"},"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Junqing Li","raw_affiliation_strings":["School of Electric and Electronics Engineering, North China Electric Power University, Baoding, China"],"affiliations":[{"raw_affiliation_string":"School of Electric and Electronics Engineering, North China Electric Power University, Baoding, China","institution_ids":["https://openalex.org/I153473198"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5086498332","display_name":"Yangshuo Ma","orcid":null},"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yangshuo Ma","raw_affiliation_strings":["School of Electric and Electronics Engineering, North China Electric Power University, Baoding, China"],"affiliations":[{"raw_affiliation_string":"School of Electric and Electronics Engineering, North China Electric Power University, Baoding, China","institution_ids":["https://openalex.org/I153473198"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5055546056","display_name":"Fuchun Sun","orcid":"https://orcid.org/0000-0003-3546-6305"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Fuchun Sun","raw_affiliation_strings":["State Grid Shandong Electric Power Research Institute, Jinan, China"],"affiliations":[{"raw_affiliation_string":"State Grid Shandong Electric Power Research Institute, Jinan, China","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5054332012"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.1192,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.46136361,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"7"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12451","display_name":"Smart Grid and Power Systems","score":0.9944999814033508,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12451","display_name":"Smart Grid and Power Systems","score":0.9944999814033508,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.9943000078201294,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.991599977016449,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.588463544845581},{"id":"https://openalex.org/keywords/turbine","display_name":"Turbine","score":0.5408544540405273},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.5177066326141357},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4864916205406189},{"id":"https://openalex.org/keywords/water-cooling","display_name":"Water cooling","score":0.44016748666763306},{"id":"https://openalex.org/keywords/synchronous-motor","display_name":"Synchronous motor","score":0.4377746880054474},{"id":"https://openalex.org/keywords/key","display_name":"Key (lock)","score":0.4211995601654053},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.3889597952365875},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.23478099703788757},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.18914929032325745},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.1881309151649475},{"id":"https://openalex.org/keywords/geology","display_name":"Geology","score":0.10946905612945557},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.07420128583908081}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.588463544845581},{"id":"https://openalex.org/C2778449969","wikidata":"https://www.wikidata.org/wiki/Q130760","display_name":"Turbine","level":2,"score":0.5408544540405273},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5177066326141357},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4864916205406189},{"id":"https://openalex.org/C7694927","wikidata":"https://www.wikidata.org/wiki/Q7667810","display_name":"Water cooling","level":2,"score":0.44016748666763306},{"id":"https://openalex.org/C71376005","wikidata":"https://www.wikidata.org/wiki/Q845675","display_name":"Synchronous motor","level":2,"score":0.4377746880054474},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.4211995601654053},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3889597952365875},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.23478099703788757},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.18914929032325745},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.1881309151649475},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.10946905612945557},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.07420128583908081},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icphm.2019.8819412","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icphm.2019.8819412","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 IEEE International Conference on Prognostics and Health Management (ICPHM)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.7300000190734863}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W1927450157","https://openalex.org/W1970767995","https://openalex.org/W1974448437","https://openalex.org/W1988618095","https://openalex.org/W2014883295","https://openalex.org/W2138624199","https://openalex.org/W2294165638","https://openalex.org/W2345147491","https://openalex.org/W2362389384","https://openalex.org/W2570690123","https://openalex.org/W2610746053","https://openalex.org/W3160393585","https://openalex.org/W6794257697"],"related_works":["https://openalex.org/W2090695973","https://openalex.org/W1977513696","https://openalex.org/W4376453582","https://openalex.org/W2362413535","https://openalex.org/W1964011233","https://openalex.org/W2013171096","https://openalex.org/W3147033875","https://openalex.org/W2355584080","https://openalex.org/W1568390478","https://openalex.org/W2744156502"],"abstract_inverted_index":{"In":[0],"the":[1,4,24,27,33,38,47,74,78,89,98,103,105,117,122],"power":[2,34],"system,":[3],"large-capacity":[5],"double":[6,48,79],"water":[7,49,80],"inner":[8,50,81],"cooled":[9,51,82],"turbine":[10],"generators":[11],"and":[12,29,43,62,65,70,93,100,119],"synchronous":[13,52,83,96,123],"condensers":[14],"occupy":[15],"a":[16,114],"certain":[17],"market":[18],"share.":[19],"Their":[20],"normal":[21],"operation":[22,31,64,69],"is":[23,54],"key":[25],"upon":[26],"safe":[28,61],"stable":[30,63],"of":[32,46,55,68,77,95,102,121],"system.":[35],"Therefore,":[36],"mastering":[37],"faults":[39,41,44,91],"types,":[40],"causes":[42,99],"characteristics":[45,76,101],"machines":[53],"great":[56],"significance":[57],"for":[58,116],"ensuring":[59],"their":[60],"reasonable":[66],"arrangement":[67],"maintenance.":[71],"Based":[72],"on":[73],"structural":[75],"machines,":[84,97],"this":[85],"paper":[86],"studies":[87],"mainly":[88],"common":[90],"locations":[92],"types":[94],"faults,":[104],"physical":[106],"quantity":[107],"to":[108],"be":[109],"monitored,":[110],"etc.,":[111],"which":[112],"provides":[113],"reference":[115],"maintenance":[118],"repair":[120],"machines.":[124]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2021,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
