{"id":"https://openalex.org/W7124164414","doi":"https://doi.org/10.1109/icpads67057.2025.11323049","title":"PPEM-BM: Portable Power Estimation Methodology for Bare Metal Servers","display_name":"PPEM-BM: Portable Power Estimation Methodology for Bare Metal Servers","publication_year":2025,"publication_date":"2025-12-14","ids":{"openalex":"https://openalex.org/W7124164414","doi":"https://doi.org/10.1109/icpads67057.2025.11323049"},"language":null,"primary_location":{"id":"doi:10.1109/icpads67057.2025.11323049","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icpads67057.2025.11323049","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 IEEE 31th International Conference on Parallel and Distributed Systems (ICPADS)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Maxime Agusti","orcid":null},"institutions":[{"id":"https://openalex.org/I4210087002","display_name":"Centre Hospitalier de Roubaix","ror":"https://ror.org/0014n6t23","country_code":"FR","type":"healthcare","lineage":["https://openalex.org/I4210087002"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Maxime Agusti","raw_affiliation_strings":["OVHcloud,Roubaix,France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"OVHcloud,Roubaix,France","institution_ids":["https://openalex.org/I4210087002"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5006723672","display_name":"Eddy Caron","orcid":"https://orcid.org/0000-0001-6626-3071"},"institutions":[{"id":"https://openalex.org/I100532134","display_name":"Universit\u00e9 Claude Bernard Lyon 1","ror":"https://ror.org/029brtt94","country_code":"FR","type":"education","lineage":["https://openalex.org/I100532134","https://openalex.org/I203339264"]},{"id":"https://openalex.org/I113428412","display_name":"\u00c9cole Normale Sup\u00e9rieure de Lyon","ror":"https://ror.org/04zmssz18","country_code":"FR","type":"education","lineage":["https://openalex.org/I113428412","https://openalex.org/I203339264"]},{"id":"https://openalex.org/I1294671590","display_name":"Centre National de la Recherche Scientifique","ror":"https://ror.org/02feahw73","country_code":"FR","type":"government","lineage":["https://openalex.org/I1294671590"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Eddy Caron","raw_affiliation_strings":["UCBL, Inria, ENS de Lyon, CNRS, LIP,Lyon,France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"UCBL, Inria, ENS de Lyon, CNRS, LIP,Lyon,France","institution_ids":["https://openalex.org/I100532134","https://openalex.org/I113428412","https://openalex.org/I1294671590"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5053990105","display_name":"Benjamin Fichel","orcid":null},"institutions":[{"id":"https://openalex.org/I4210087002","display_name":"Centre Hospitalier de Roubaix","ror":"https://ror.org/0014n6t23","country_code":"FR","type":"healthcare","lineage":["https://openalex.org/I4210087002"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Benjamin Fichel","raw_affiliation_strings":["OVHcloud,Roubaix,France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"OVHcloud,Roubaix,France","institution_ids":["https://openalex.org/I4210087002"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5086221846","display_name":"Laurent Lef\u00e8vre","orcid":"https://orcid.org/0000-0002-5496-5882"},"institutions":[{"id":"https://openalex.org/I100532134","display_name":"Universit\u00e9 Claude Bernard Lyon 1","ror":"https://ror.org/029brtt94","country_code":"FR","type":"education","lineage":["https://openalex.org/I100532134","https://openalex.org/I203339264"]},{"id":"https://openalex.org/I113428412","display_name":"\u00c9cole Normale Sup\u00e9rieure de Lyon","ror":"https://ror.org/04zmssz18","country_code":"FR","type":"education","lineage":["https://openalex.org/I113428412","https://openalex.org/I203339264"]},{"id":"https://openalex.org/I1294671590","display_name":"Centre National de la Recherche Scientifique","ror":"https://ror.org/02feahw73","country_code":"FR","type":"government","lineage":["https://openalex.org/I1294671590"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Laurent Lef\u00e8vre","raw_affiliation_strings":["UCBL, Inria, ENS de Lyon, CNRS, LIP,Lyon,France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"UCBL, Inria, ENS de Lyon, CNRS, LIP,Lyon,France","institution_ids":["https://openalex.org/I100532134","https://openalex.org/I113428412","https://openalex.org/I1294671590"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5109821212","display_name":"Olivier Nicol","orcid":null},"institutions":[{"id":"https://openalex.org/I4210087002","display_name":"Centre Hospitalier de Roubaix","ror":"https://ror.org/0014n6t23","country_code":"FR","type":"healthcare","lineage":["https://openalex.org/I4210087002"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Olivier Nicol","raw_affiliation_strings":["OVHcloud,Roubaix,France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"OVHcloud,Roubaix,France","institution_ids":["https://openalex.org/I4210087002"]}]},{"author_position":"last","author":{"id":null,"display_name":"Anne-C\u00e9cile Orgerie","orcid":null},"institutions":[{"id":"https://openalex.org/I1294671590","display_name":"Centre National de la Recherche Scientifique","ror":"https://ror.org/02feahw73","country_code":"FR","type":"government","lineage":["https://openalex.org/I1294671590"]},{"id":"https://openalex.org/I2802519937","display_name":"Institut de Recherche en Informatique et Syst\u00e8mes Al\u00e9atoires","ror":"https://ror.org/00myn0z94","country_code":"FR","type":"facility","lineage":["https://openalex.org/I1294671590","https://openalex.org/I1294671590","https://openalex.org/I1326498283","https://openalex.org/I205703379","https://openalex.org/I2802204017","https://openalex.org/I2802519937","https://openalex.org/I28221208","https://openalex.org/I4210127572","https://openalex.org/I4210159245","https://openalex.org/I56067802"]},{"id":"https://openalex.org/I56067802","display_name":"Universit\u00e9 de Rennes","ror":"https://ror.org/015m7wh34","country_code":"FR","type":"education","lineage":["https://openalex.org/I56067802"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Anne-C\u00e9cile Orgerie","raw_affiliation_strings":["Univ. Rennes, Inria, CNRS, IRISA,Rennes,France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Univ. Rennes, Inria, CNRS, IRISA,Rennes,France","institution_ids":["https://openalex.org/I2802519937","https://openalex.org/I56067802","https://openalex.org/I1294671590"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":6,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"8"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12238","display_name":"Green IT and Sustainability","score":0.26969999074935913,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12238","display_name":"Green IT and Sustainability","score":0.26969999074935913,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10101","display_name":"Cloud Computing and Resource Management","score":0.24529999494552612,"subfield":{"id":"https://openalex.org/subfields/1710","display_name":"Information Systems"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.09780000150203705,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/server","display_name":"Server","score":0.8199999928474426},{"id":"https://openalex.org/keywords/software-deployment","display_name":"Software deployment","score":0.5838000178337097},{"id":"https://openalex.org/keywords/cloud-computing","display_name":"Cloud computing","score":0.5680000185966492},{"id":"https://openalex.org/keywords/data-center","display_name":"Data center","score":0.5238999724388123},{"id":"https://openalex.org/keywords/key","display_name":"Key (lock)","score":0.5134999752044678},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.47119998931884766},{"id":"https://openalex.org/keywords/green-computing","display_name":"Green computing","score":0.45570001006126404},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4415000081062317},{"id":"https://openalex.org/keywords/central-processing-unit","display_name":"Central processing unit","score":0.43130001425743103},{"id":"https://openalex.org/keywords/sustainability","display_name":"Sustainability","score":0.41679999232292175}],"concepts":[{"id":"https://openalex.org/C93996380","wikidata":"https://www.wikidata.org/wiki/Q44127","display_name":"Server","level":2,"score":0.8199999928474426},{"id":"https://openalex.org/C105339364","wikidata":"https://www.wikidata.org/wiki/Q2297740","display_name":"Software deployment","level":2,"score":0.5838000178337097},{"id":"https://openalex.org/C79974875","wikidata":"https://www.wikidata.org/wiki/Q483639","display_name":"Cloud computing","level":2,"score":0.5680000185966492},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5404000282287598},{"id":"https://openalex.org/C153740404","wikidata":"https://www.wikidata.org/wiki/Q671224","display_name":"Data center","level":2,"score":0.5238999724388123},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.5134999752044678},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.47119998931884766},{"id":"https://openalex.org/C75027835","wikidata":"https://www.wikidata.org/wiki/Q1064746","display_name":"Green computing","level":3,"score":0.45570001006126404},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4415000081062317},{"id":"https://openalex.org/C49154492","wikidata":"https://www.wikidata.org/wiki/Q5300","display_name":"Central processing unit","level":2,"score":0.43130001425743103},{"id":"https://openalex.org/C66204764","wikidata":"https://www.wikidata.org/wiki/Q219416","display_name":"Sustainability","level":2,"score":0.41679999232292175},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.39590001106262207},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.3887999951839447},{"id":"https://openalex.org/C30772137","wikidata":"https://www.wikidata.org/wiki/Q5164762","display_name":"Consumption (sociology)","level":2,"score":0.38670000433921814},{"id":"https://openalex.org/C2779547435","wikidata":"https://www.wikidata.org/wiki/Q1121492","display_name":"Directive","level":2,"score":0.3700999915599823},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3529999852180481},{"id":"https://openalex.org/C4373008","wikidata":"https://www.wikidata.org/wiki/Q513349","display_name":"File server","level":2,"score":0.3296999931335449},{"id":"https://openalex.org/C67186912","wikidata":"https://www.wikidata.org/wiki/Q367664","display_name":"Data modeling","level":2,"score":0.32190001010894775},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.3093000054359436},{"id":"https://openalex.org/C24590314","wikidata":"https://www.wikidata.org/wiki/Q336038","display_name":"Wireless sensor network","level":2,"score":0.2978000044822693},{"id":"https://openalex.org/C2984118289","wikidata":"https://www.wikidata.org/wiki/Q29954","display_name":"Power consumption","level":3,"score":0.29159998893737793},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.28859999775886536},{"id":"https://openalex.org/C77088390","wikidata":"https://www.wikidata.org/wiki/Q8513","display_name":"Database","level":1,"score":0.28200000524520874},{"id":"https://openalex.org/C46934059","wikidata":"https://www.wikidata.org/wiki/Q61515","display_name":"Outsourcing","level":2,"score":0.2806999981403351},{"id":"https://openalex.org/C47737302","wikidata":"https://www.wikidata.org/wiki/Q167336","display_name":"Greenhouse gas","level":2,"score":0.2799000144004822},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.27900001406669617},{"id":"https://openalex.org/C423512","wikidata":"https://www.wikidata.org/wiki/Q383973","display_name":"Electricity generation","level":3,"score":0.2770000100135803},{"id":"https://openalex.org/C168292644","wikidata":"https://www.wikidata.org/wiki/Q10860336","display_name":"Power optimization","level":4,"score":0.27250000834465027},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2718000113964081},{"id":"https://openalex.org/C134560507","wikidata":"https://www.wikidata.org/wiki/Q753291","display_name":"Environmental economics","level":1,"score":0.2687000036239624},{"id":"https://openalex.org/C520301825","wikidata":"https://www.wikidata.org/wiki/Q380170","display_name":"Energy conservation","level":2,"score":0.2671999931335449},{"id":"https://openalex.org/C164226766","wikidata":"https://www.wikidata.org/wiki/Q7293202","display_name":"Rank (graph theory)","level":2,"score":0.26510000228881836},{"id":"https://openalex.org/C2987335383","wikidata":"https://www.wikidata.org/wiki/Q878048","display_name":"Cloud server","level":3,"score":0.2648000121116638},{"id":"https://openalex.org/C72293138","wikidata":"https://www.wikidata.org/wiki/Q909741","display_name":"Temperature measurement","level":2,"score":0.26350000500679016},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.26109999418258667},{"id":"https://openalex.org/C2778449969","wikidata":"https://www.wikidata.org/wiki/Q130760","display_name":"Turbine","level":2,"score":0.257999986410141},{"id":"https://openalex.org/C11392498","wikidata":"https://www.wikidata.org/wiki/Q11288","display_name":"Web server","level":3,"score":0.2572999894618988},{"id":"https://openalex.org/C2780936489","wikidata":"https://www.wikidata.org/wiki/Q310667","display_name":"Carbon footprint","level":3,"score":0.2513999938964844}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icpads67057.2025.11323049","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icpads67057.2025.11323049","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 IEEE 31th International Conference on Parallel and Distributed Systems (ICPADS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320333359","display_name":"College of Natural Resources and Sciences, Humboldt State University","ror":null}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W1977661221","https://openalex.org/W2284351912","https://openalex.org/W2295598076","https://openalex.org/W2903324874","https://openalex.org/W2924789150","https://openalex.org/W3015015599","https://openalex.org/W3043883126","https://openalex.org/W3088267381","https://openalex.org/W3209312816","https://openalex.org/W4251091605","https://openalex.org/W4291809939","https://openalex.org/W4327615886","https://openalex.org/W4391299721","https://openalex.org/W4394628736","https://openalex.org/W4400345191","https://openalex.org/W4403350018"],"related_works":[],"abstract_inverted_index":{"In":[0],"an":[1,28],"effort":[2],"to":[3,23,69,108,117,121,163,182],"raise":[4],"awareness":[5],"on":[6,133,144,167],"the":[7,14,31,47,71,89,123],"increasing":[8],"carbon":[9,32],"emissions":[10],"of":[11,30,49,74],"Cloud":[12],"computing,":[13],"European":[15],"Corporate":[16],"Sustainability":[17],"Reporting":[18],"Directive":[19],"effectively":[20],"requires":[21],"providers":[22,181],"supply":[24],"their":[25,36,110],"customers":[26],"with":[27,35,97],"assessment":[29],"impact":[33],"associated":[34],"use.":[37],"This":[38],"represents":[39],"a":[40,64,115,129,159,173],"challenge":[41],"for":[42,128,179],"bare":[43,75],"metal":[44,76],"servers,":[45],"where":[46],"deployment":[48],"dedicated":[50],"power":[51,72,104],"meters":[52],"is":[53],"often":[54],"unfeasible":[55],"at":[56,153],"scale.":[57],"To":[58],"address":[59],"this,":[60],"we":[61],"present":[62],"PPEM-BM,":[63],"novel":[65],"sensor-driven":[66],"modeling":[67],"approach":[68,171],"estimate":[70],"consumption":[73,185],"servers":[77,152],"using":[78,114],"CPU":[79,95,138],"temperature":[80,96,139],"data":[81],"acquired":[82],"via":[83],"IPMI.":[84],"PPEM-BM":[85,157],"enhances":[86],"and":[87,112,137,176],"generalizes":[88],"existing":[90],"PowerHeat":[91],"method,":[92],"which":[93],"correlates":[94],"power.":[98],"Our":[99],"methodology":[100],"involves":[101],"training":[102],"individual":[103],"models,":[105],"performing":[106],"cross-evaluation":[107],"determine":[109],"portability,":[111],"then":[113],"Learning":[116],"Rank":[118],"(LTR)":[119],"model":[120,127],"select":[122],"most":[124],"appropriate":[125],"pre-trained":[126],"target":[130],"server":[131],"based":[132,165],"its":[134],"hardware":[135,168],"configuration":[136],"statistics.":[140],"An":[141],"experiment":[142],"conducted":[143],"<tex":[145],"xmlns:mml=\"http://www.w3.org/1998/Math/MathML\"":[146],"xmlns:xlink=\"http://www.w3.org/1999/xlink\">$\\mathbf{1,":[147],"0":[148],"7":[149],"6}$</tex>":[150],"production":[151],"OVHcloud":[154],"shows":[155],"that":[156],"demonstrates":[158],"significant":[160],"improvement":[161],"compared":[162],"models":[164],"solely":[166],"profiles.":[169],"The":[170],"offers":[172],"practical,":[174],"scalable,":[175],"cost-effective":[177],"solution":[178],"hosting":[180],"monitor":[183],"energy":[184],"without":[186],"widespread":[187],"sensor":[188],"deployment.":[189]},"counts_by_year":[],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2026-01-15T00:00:00"}
