{"id":"https://openalex.org/W2743048981","doi":"https://doi.org/10.1109/icorr.2017.8009391","title":"Novel neural interface electrode array for the peripheral nerve","display_name":"Novel neural interface electrode array for the peripheral nerve","publication_year":2017,"publication_date":"2017-07-01","ids":{"openalex":"https://openalex.org/W2743048981","doi":"https://doi.org/10.1109/icorr.2017.8009391","mag":"2743048981","pmid":"https://pubmed.ncbi.nlm.nih.gov/28813963"},"language":"en","primary_location":{"id":"doi:10.1109/icorr.2017.8009391","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icorr.2017.8009391","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 International Conference on Rehabilitation Robotics (ICORR)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5030538809","display_name":"Ockchul Kim","orcid":"https://orcid.org/0000-0002-9351-1621"},"institutions":[{"id":"https://openalex.org/I88761825","display_name":"Korea University of Science and Technology","ror":"https://ror.org/000qzf213","country_code":"KR","type":"education","lineage":["https://openalex.org/I88761825"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Ockchul Kim","raw_affiliation_strings":["Republic of Korea and the department of Biomedical Engineering, University of Science and Technology, Daeieon, Seoul, Yuseong-gu, Republic of Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Republic of Korea and the department of Biomedical Engineering, University of Science and Technology, Daeieon, Seoul, Yuseong-gu, Republic of Korea","institution_ids":["https://openalex.org/I88761825"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5018998846","display_name":"Wonsuk Choi","orcid":"https://orcid.org/0000-0002-8224-5807"},"institutions":[{"id":"https://openalex.org/I58716616","display_name":"Korea Institute of Science and Technology","ror":"https://ror.org/05kzfa883","country_code":"KR","type":"facility","lineage":["https://openalex.org/I27494661","https://openalex.org/I2801339556","https://openalex.org/I2801339556","https://openalex.org/I4210144908","https://openalex.org/I4387152098","https://openalex.org/I4387152098","https://openalex.org/I58716616"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Wonsuk Choi","raw_affiliation_strings":["Center for Bionics of Korea Institute of Science and technology, Seoul, Seongbuk-au, Renublic of Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Center for Bionics of Korea Institute of Science and technology, Seoul, Seongbuk-au, Renublic of Korea","institution_ids":["https://openalex.org/I58716616"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5054018650","display_name":"Woohyun Jung","orcid":"https://orcid.org/0000-0002-8058-4274"},"institutions":[{"id":"https://openalex.org/I197347611","display_name":"Korea University","ror":"https://ror.org/047dqcg40","country_code":"KR","type":"education","lineage":["https://openalex.org/I197347611"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Woohyun Jung","raw_affiliation_strings":["Department of mechanical engineering, Korea University, Seoul, Seongbuk-gu, Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of mechanical engineering, Korea University, Seoul, Seongbuk-gu, Korea","institution_ids":["https://openalex.org/I197347611"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5108479947","display_name":"Sunyoung Jung","orcid":null},"institutions":[{"id":"https://openalex.org/I58716616","display_name":"Korea Institute of Science and Technology","ror":"https://ror.org/05kzfa883","country_code":"KR","type":"facility","lineage":["https://openalex.org/I27494661","https://openalex.org/I2801339556","https://openalex.org/I2801339556","https://openalex.org/I4210144908","https://openalex.org/I4387152098","https://openalex.org/I4387152098","https://openalex.org/I58716616"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Sunyoung Jung","raw_affiliation_strings":["Center for Bionics of Korea Institute of Science and technology Seongbuk-gu, Seoul, Republic of Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Center for Bionics of Korea Institute of Science and technology Seongbuk-gu, Seoul, Republic of Korea","institution_ids":["https://openalex.org/I58716616"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5074967227","display_name":"HyungDal Park","orcid":"https://orcid.org/0000-0001-5019-6134"},"institutions":[{"id":"https://openalex.org/I193775966","display_name":"Yonsei University","ror":"https://ror.org/01wjejq96","country_code":"KR","type":"education","lineage":["https://openalex.org/I193775966"]},{"id":"https://openalex.org/I4210140519","display_name":"Korean Association Of Science and Technology Studies","ror":"https://ror.org/04qh86j58","country_code":"KR","type":"other","lineage":["https://openalex.org/I4210140519"]},{"id":"https://openalex.org/I58716616","display_name":"Korea Institute of Science and Technology","ror":"https://ror.org/05kzfa883","country_code":"KR","type":"facility","lineage":["https://openalex.org/I27494661","https://openalex.org/I2801339556","https://openalex.org/I2801339556","https://openalex.org/I4210144908","https://openalex.org/I4387152098","https://openalex.org/I4387152098","https://openalex.org/I58716616"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"HyungDal Park","raw_affiliation_strings":["Center for Bionics of Korea Institute of Science and Technology, School of Mechanical Engineering of Yonsei University, Seoul, Seodaemun-gu, Republic of Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Center for Bionics of Korea Institute of Science and Technology, School of Mechanical Engineering of Yonsei University, Seoul, Seodaemun-gu, Republic of Korea","institution_ids":["https://openalex.org/I193775966","https://openalex.org/I4210140519","https://openalex.org/I58716616"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101438348","display_name":"Jong Woong Park","orcid":"https://orcid.org/0000-0003-2751-2519"},"institutions":[{"id":"https://openalex.org/I197347611","display_name":"Korea University","ror":"https://ror.org/047dqcg40","country_code":"KR","type":"education","lineage":["https://openalex.org/I197347611"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Jong Woong Park","raw_affiliation_strings":["College of Medicine, Korea University, Seoul, Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"College of Medicine, Korea University, Seoul, Korea","institution_ids":["https://openalex.org/I197347611"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100757436","display_name":"Jinseok Kim","orcid":"https://orcid.org/0000-0002-4778-8144"},"institutions":[{"id":"https://openalex.org/I58716616","display_name":"Korea Institute of Science and Technology","ror":"https://ror.org/05kzfa883","country_code":"KR","type":"facility","lineage":["https://openalex.org/I27494661","https://openalex.org/I2801339556","https://openalex.org/I2801339556","https://openalex.org/I4210144908","https://openalex.org/I4387152098","https://openalex.org/I4387152098","https://openalex.org/I58716616"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Jinseok Kim","raw_affiliation_strings":["Center for Bionics of Korea Institute of Science and technology Seongbuk-gu, Seoul, Republic of Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Center for Bionics of Korea Institute of Science and technology Seongbuk-gu, Seoul, Republic of Korea","institution_ids":["https://openalex.org/I58716616"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":8,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":"28","issue":null,"first_page":"1067","last_page":"1072"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11601","display_name":"Neuroscience and Neural Engineering","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2804","display_name":"Cellular and Molecular Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},"topics":[{"id":"https://openalex.org/T11601","display_name":"Neuroscience and Neural Engineering","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2804","display_name":"Cellular and Molecular Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},{"id":"https://openalex.org/T10784","display_name":"Muscle activation and electromyography studies","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10429","display_name":"EEG and Brain-Computer Interfaces","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2805","display_name":"Cognitive Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/signal","display_name":"SIGNAL (programming language)","score":0.6156095266342163},{"id":"https://openalex.org/keywords/electrical-impedance","display_name":"Electrical impedance","score":0.6154429912567139},{"id":"https://openalex.org/keywords/interface","display_name":"Interface (matter)","score":0.5954392552375793},{"id":"https://openalex.org/keywords/electrode-array","display_name":"Electrode array","score":0.565612256526947},{"id":"https://openalex.org/keywords/electrode","display_name":"Electrode","score":0.5636793971061707},{"id":"https://openalex.org/keywords/spiral","display_name":"Spiral (railway)","score":0.5543632507324219},{"id":"https://openalex.org/keywords/neural-prosthesis","display_name":"Neural Prosthesis","score":0.5514979958534241},{"id":"https://openalex.org/keywords/peripheral","display_name":"Peripheral","score":0.5395954847335815},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.5087302327156067},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5022745132446289},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.45573267340660095},{"id":"https://openalex.org/keywords/peripheral-nerve","display_name":"Peripheral nerve","score":0.4500933587551117},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.35352736711502075},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.2045668363571167},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.17370587587356567},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.14235210418701172},{"id":"https://openalex.org/keywords/chemistry","display_name":"Chemistry","score":0.11848965287208557},{"id":"https://openalex.org/keywords/anatomy","display_name":"Anatomy","score":0.0844561755657196}],"concepts":[{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.6156095266342163},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.6154429912567139},{"id":"https://openalex.org/C113843644","wikidata":"https://www.wikidata.org/wiki/Q901882","display_name":"Interface (matter)","level":4,"score":0.5954392552375793},{"id":"https://openalex.org/C97562148","wikidata":"https://www.wikidata.org/wiki/Q5357989","display_name":"Electrode array","level":3,"score":0.565612256526947},{"id":"https://openalex.org/C17525397","wikidata":"https://www.wikidata.org/wiki/Q176140","display_name":"Electrode","level":2,"score":0.5636793971061707},{"id":"https://openalex.org/C174128100","wikidata":"https://www.wikidata.org/wiki/Q846907","display_name":"Spiral (railway)","level":2,"score":0.5543632507324219},{"id":"https://openalex.org/C2908765479","wikidata":"https://www.wikidata.org/wiki/Q1431093","display_name":"Neural Prosthesis","level":2,"score":0.5514979958534241},{"id":"https://openalex.org/C46762472","wikidata":"https://www.wikidata.org/wiki/Q178648","display_name":"Peripheral","level":2,"score":0.5395954847335815},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.5087302327156067},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5022745132446289},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.45573267340660095},{"id":"https://openalex.org/C3018498973","wikidata":"https://www.wikidata.org/wiki/Q9620","display_name":"Peripheral nerve","level":2,"score":0.4500933587551117},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.35352736711502075},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2045668363571167},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.17370587587356567},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.14235210418701172},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.11848965287208557},{"id":"https://openalex.org/C105702510","wikidata":"https://www.wikidata.org/wiki/Q514","display_name":"Anatomy","level":1,"score":0.0844561755657196},{"id":"https://openalex.org/C173608175","wikidata":"https://www.wikidata.org/wiki/Q232661","display_name":"Parallel computing","level":1,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C147789679","wikidata":"https://www.wikidata.org/wiki/Q11372","display_name":"Physical chemistry","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C129307140","wikidata":"https://www.wikidata.org/wiki/Q6795880","display_name":"Maximum bubble pressure method","level":3,"score":0.0},{"id":"https://openalex.org/C157915830","wikidata":"https://www.wikidata.org/wiki/Q2928001","display_name":"Bubble","level":2,"score":0.0}],"mesh":[{"descriptor_ui":"D001186","descriptor_name":"Artificial Limbs","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001186","descriptor_name":"Artificial Limbs","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001186","descriptor_name":"Artificial Limbs","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004566","descriptor_name":"Electrodes","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004566","descriptor_name":"Electrodes","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004566","descriptor_name":"Electrodes","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004576","descriptor_name":"Electromyography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D004576","descriptor_name":"Electromyography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D004576","descriptor_name":"Electromyography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010525","descriptor_name":"Peripheral Nerves","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D010525","descriptor_name":"Peripheral Nerves","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D010525","descriptor_name":"Peripheral Nerves","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D012371","descriptor_name":"Robotics","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D012371","descriptor_name":"Robotics","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D012371","descriptor_name":"Robotics","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D058117","descriptor_name":"Neural Prostheses","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D058117","descriptor_name":"Neural Prostheses","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D058117","descriptor_name":"Neural Prostheses","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true}],"locations_count":2,"locations":[{"id":"doi:10.1109/icorr.2017.8009391","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icorr.2017.8009391","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 International Conference on Rehabilitation Robotics (ICORR)","raw_type":"proceedings-article"},{"id":"pmid:28813963","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/28813963","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE ... International Conference on Rehabilitation Robotics : [proceedings]","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":19,"referenced_works":["https://openalex.org/W97186611","https://openalex.org/W1499820070","https://openalex.org/W1581065997","https://openalex.org/W1987886407","https://openalex.org/W1990505926","https://openalex.org/W1999715507","https://openalex.org/W2014165332","https://openalex.org/W2024049244","https://openalex.org/W2026234338","https://openalex.org/W2088561379","https://openalex.org/W2095666645","https://openalex.org/W2122612627","https://openalex.org/W2134500330","https://openalex.org/W2135648815","https://openalex.org/W2138970539","https://openalex.org/W2248997372","https://openalex.org/W2334234243","https://openalex.org/W6604053674","https://openalex.org/W6634733033"],"related_works":["https://openalex.org/W2418268755","https://openalex.org/W4245110754","https://openalex.org/W288040584","https://openalex.org/W2412017198","https://openalex.org/W1969815369","https://openalex.org/W2803245432","https://openalex.org/W2795303445","https://openalex.org/W2137852641","https://openalex.org/W1998401450","https://openalex.org/W2040335976"],"abstract_inverted_index":{"Peripheral":[0],"neural":[1,22,38,80],"interface":[2],"(PNI)":[3],"is":[4],"becoming":[5],"an":[6,96],"essential":[7],"technology":[8],"in":[9,89],"the":[10,26,30,42,45,76,92],"field":[11],"of":[12,44,99],"robotic":[13],"prosthesis":[14],"due":[15],"to":[16],"its":[17],"potential":[18],"for":[19,71],"providing":[20],"bidirectional":[21],"signal":[23,39,59,81],"communication":[24],"between":[25],"prosthetic":[27],"arm":[28],"and":[29,41,49,91],"brain.":[31],"However,":[32],"current":[33],"PNIs":[34],"inefficiently":[35],"trade":[36],"off":[37],"selectivity":[40,60],"invasiveness":[43,64],"device.":[46],"We":[47],"designed":[48],"fabricated":[50],"a":[51,67],"new":[52],"PNI":[53],"electrode":[54],"array":[55],"that":[56,69],"has":[57],"high":[58],"yet":[61],"maintains":[62],"low":[63],"by":[65],"incorporating":[66],"design":[68],"allows":[70],"three-dimensional":[72],"spiral":[73],"insertion":[74],"around":[75],"peripheral":[77],"nerve.":[78],"The":[79],"acquisition":[82],"capability":[83],"was":[84],"confirmed":[85],"through":[86],"impedance":[87,98],"measurement":[88],"vitro,":[90],"proposed":[93],"device":[94],"had":[95],"average":[97],"296":[100],"\u00b1":[101],"52":[102],"k\u03a9":[103],"at":[104],"1000":[105],"Hz.":[106]},"counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":2},{"year":2018,"cited_by_count":2}],"updated_date":"2026-07-22T07:51:19.307946","created_date":"2025-10-10T00:00:00"}
